NR2A-Fuse 000/80 aR 700VDC/690VAC with ind. w/o lug 125A

Reference 180.801.43.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 125
Rated Voltage Un AC (V) 690
Dimension 000
Applicable standards IEC
Power loss (W) 27,5
Rated Voltage Un DC (V) 700
Time costant L/R (ms) 2
Series name NR2A
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 2100
Fuse Connection/Terminal type Screw fixing
Fixing connection centres (mm) 80
Voltage of total clearing I2t test 700
Total clearing I²t @Un AC (A²s) 7700
Rated breaking capacity I1 AC (kA) 200000
Price List €13.22/pc
Quantity

UR22 - Fuse 690V AC 22x58 fixing 80mm 100A

Reference 180.960.54.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 100
Rated Voltage Un AC (V) 690
Applicable standards IEC
Power loss (W) 19,1
Series name UR22
Fuse Dimension (mm) 22x58
Melting I²t value (A²s) 2150
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 9345
Rated breaking capacity I1 AC (kA) 200000
Product available on request Ask for more information

NR2A - Fuse DIN000 80mm aR 700VDC/690VAC no ind 160A

Reference 193.430.72.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 160
Rated Voltage Un AC (V) 690
Dimension 000
Applicable standards IEC
Power loss (W) 37,5
Rated Voltage Un DC (V) 700
Time costant L/R (ms) 2
Series name NR2A
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 3020
Fuse Connection/Terminal type Screw fixing
Fixing connection centres (mm) 80
Voltage of total clearing I2t test 700
Total clearing I²t @Un AC (A²s) 11100
Rated breaking capacity I1 AC (kA) 200000
Price List €14.05/pc
Quantity

RL12 - Fuse 25x60mm 125VDC 275A

Reference 205.377.12.0.0 - Manufacturer FAULTRAP
Rated current In (A) 275
Power loss (W) 23
Rated Voltage Un DC (V) 125
Time costant L/R (ms) 3
Series name RL12
Rated breaking capacity I1 DC (kA) 10000
Melting I²t value (A²s) 8650
Total clearing I²t @Un AC (A²s) 75000
Price List €5.61/pc
Quantity

V108 - Fuse 10x85 1500VDC gPV UL 32A

Reference 210.825.49.0.0 - Manufacturer FAULTRAP
Class gPV
Rated current In (A) 32
Applicable standards IEC, UL
Power loss (W) 7,72
Rated Voltage Un DC (V) 1500
Series name V108
Rated breaking capacity I1 DC (kA) 20000
Fuse Dimension (mm) 10x85
Melting I²t value (A²s) 299,64
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 4286
Weight (gr) 12
Price List €26.74/pc
Quantity

NR2A - Fuse DIN000 80mm aR 700VDC/690VAC no ind 40A

Reference 214.646.89.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 40
Rated Voltage Un AC (V) 690
Dimension 000
Applicable standards IEC
Power loss (W) 7,2
Rated Voltage Un DC (V) 700
Time costant L/R (ms) 2
Series name NR2A
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 230
Fuse Connection/Terminal type Screw fixing
Fixing connection centres (mm) 80
Voltage of total clearing I2t test 700
Total clearing I²t @Un AC (A²s) 840
Rated breaking capacity I1 AC (kA) 200000
Price List €9.98/pc
Quantity

RL12 - Fuse 25x60mm 125VDC 350A

Reference 220.677.57.0.0 - Manufacturer FAULTRAP
Rated current In (A) 350
Power loss (W) 32
Rated Voltage Un DC (V) 125
Time costant L/R (ms) 3
Series name RL12
Rated breaking capacity I1 DC (kA) 10000
Melting I²t value (A²s) 16200
Total clearing I²t @Un AC (A²s) 155000
Price List €6.86/pc
Quantity

NR2B - Fuse DIN00 80mm aR 700VDC/690VAC with ind. lug 80A

Reference 245.542.07.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 80
Rated Voltage Un AC (V) 690
Dimension 000
Applicable standards IEC, UL
Power loss (W) 17
Rated Voltage Un DC (V) 700
Time costant L/R (ms) 2
Series name NR2B
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 750
Fuse Connection/Terminal type Screw fixing
Fixing connection centres (mm) 80
Voltage of total clearing I2t test 700
Total clearing I²t @Un AC (A²s) 2800
Rated breaking capacity I1 AC (kA) 200000
Product available on request Ask for more information

NR2A-Fuse 000/80 aR 700VDC/690VAC with ind. w/o lug 63A

Reference 247.278.11.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 63
Rated Voltage Un AC (V) 690
Dimension 000
Applicable standards IEC
Power loss (W) 9.5
Rated Voltage Un DC (V) 700
Time costant L/R (ms) 2
Series name NR2A
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 520
Fuse Connection/Terminal type Screw fixing
Fixing connection centres (mm) 80
Voltage of total clearing I2t test 700
Total clearing I²t @Un AC (A²s) 1900
Rated breaking capacity I1 AC (kA) 200000
Product available on request Ask for more information

UR22 - Fuse 690V AC 22x58 fixing on pcb 80A

Reference 265.359.20.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 80
Rated Voltage Un AC (V) 690
Applicable standards IEC
Power loss (W) 16,3
Series name UR22
Fuse Dimension (mm) 22x58
Melting I²t value (A²s) 1055
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 4620
Rated breaking capacity I1 AC (kA) 200000
Product available on request Ask for more information

NR2A-Fuse 000/80 aR 700VDC/690VAC with ind. w/o lug 80A

Reference 298.939.97.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 80
Rated Voltage Un AC (V) 690
Dimension 000
Applicable standards IEC
Power loss (W) 17
Rated Voltage Un DC (V) 700
Time costant L/R (ms) 2
Series name NR2A
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 750
Fuse Connection/Terminal type Screw fixing
Fixing connection centres (mm) 80
Voltage of total clearing I2t test 700
Total clearing I²t @Un AC (A²s) 2800
Rated breaking capacity I1 AC (kA) 200000
Product available on request Ask for more information

NR2A - Fuse DIN000 80mm aR 700VDC/690VAC with ind. lug 315A

Reference 301.249.46.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 315
Rated Voltage Un AC (V) 690
Dimension 000
Applicable standards IEC
Power loss (W) 70
Rated Voltage Un DC (V) 700
Time costant L/R (ms) 2
Series name NR2A
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 16450
Fuse Connection/Terminal type Screw fixing
Fixing connection centres (mm) 80
Voltage of total clearing I2t test 700
Total clearing I²t @Un AC (A²s) 60000
Rated breaking capacity I1 AC (kA) 200000
Price List €61.78/pc
Quantity

NR2B - Fuse DIN00 80mm aR 700VDC/690VAC with ind. lug 40A

Reference 302.935.93.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 40
Rated Voltage Un AC (V) 690
Dimension 000
Applicable standards IEC, UL
Power loss (W) 7.2
Rated Voltage Un DC (V) 700
Time costant L/R (ms) 2
Series name NR2B
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 230
Fuse Connection/Terminal type Screw fixing
Fixing connection centres (mm) 80
Voltage of total clearing I2t test 700
Total clearing I²t @Un AC (A²s) 840
Rated breaking capacity I1 AC (kA) 200000
Product available on request Ask for more information

UR22 - Fuse 690V AC 22x58 fixing on pcb 40A

Reference 306.349.41.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 40
Rated Voltage Un AC (V) 690
Applicable standards IEC
Power loss (W) 9,6
Series name UR22
Fuse Dimension (mm) 22x58
Melting I²t value (A²s) 148
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 640
Rated breaking capacity I1 AC (kA) 200000
Product available on request Ask for more information

NR2A - Fuse DIN000 80mm aR 700VDC/690VAC with ind. lug 250A

Reference 306.749.97.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 250
Rated Voltage Un AC (V) 690
Dimension 000
Applicable standards IEC
Power loss (W) 57
Rated Voltage Un DC (V) 700
Time costant L/R (ms) 2
Series name NR2A
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 10150
Fuse Connection/Terminal type Screw fixing
Fixing connection centres (mm) 80
Voltage of total clearing I2t test 700
Total clearing I²t @Un AC (A²s) 37100
Rated breaking capacity I1 AC (kA) 200000
Price List €58.81/pc
Quantity

SP22 - Fuse 500VAC 80mm SPD protection 22x58 25kA 10/350us

Reference 310.865.56.0.0 - Manufacturer FAULTRAP
Rated Voltage Un AC (V) 500
Applicable standards IEC
Series name SP22
Fuse Dimension (mm) 22x58
Melting I²t value (A²s) 197000
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 550
Total clearing I²t @Un AC (A²s) 430000
Rated breaking capacity I1 AC (kA) 100000
Price List €16.93/pc
Quantity

V108 - Fuse 10x85 1500VDC gPV UL 2A

Reference 322.946.60.0.0 - Manufacturer FAULTRAP
Class gPV
Rated current In (A) 2
Applicable standards IEC, UL
Power loss (W) 1,66
Rated Voltage Un DC (V) 1500
Series name V108
Rated breaking capacity I1 DC (kA) 20000
Fuse Dimension (mm) 10x85
Melting I²t value (A²s) 4,15
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 10
Weight (gr) 12
Price List €1.88/pc
Quantity

NR2A - Fuse DIN000 80mm aR 700VDC/690VAC with ind. lug 25A

Reference 324.047.75.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 25
Rated Voltage Un AC (V) 690
Dimension 000
Applicable standards IEC
Power loss (W) 4,6
Rated Voltage Un DC (V) 700
Time costant L/R (ms) 2
Series name NR2A
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 55
Fuse Connection/Terminal type Screw fixing
Fixing connection centres (mm) 80
Voltage of total clearing I2t test 700
Total clearing I²t @Un AC (A²s) 200
Rated breaking capacity I1 AC (kA) 200000
Product available on request Ask for more information

V108 - Fuse 10x85 1500VDC gPV UL 16A

Reference 328.230.50.0.0 - Manufacturer FAULTRAP
Class gPV
Rated current In (A) 16
Applicable standards IEC, UL
Power loss (W) 3,8
Rated Voltage Un DC (V) 1500
Series name V108
Rated breaking capacity I1 DC (kA) 20000
Fuse Dimension (mm) 10x85
Melting I²t value (A²s) 43,8
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 316
Weight (gr) 12
Price List €13.14/pc
Quantity

NR2B - Fuse DIN00 80mm aR 700VDC/690VAC with ind. lug 63A

Reference 329.443.55.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 63
Rated Voltage Un AC (V) 690
Dimension 000
Applicable standards IEC, UL
Power loss (W) 9.5
Rated Voltage Un DC (V) 700
Time costant L/R (ms) 2
Series name NR2B
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 520
Fuse Connection/Terminal type Screw fixing
Fixing connection centres (mm) 80
Voltage of total clearing I2t test 700
Total clearing I²t @Un AC (A²s) 1900
Rated breaking capacity I1 AC (kA) 200000
Product available on request Ask for more information

NR2A - Fuse DIN000 80mm aR 700VDC/690VAC with ind. lug 80A

Reference 331.496.30.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 80
Rated Voltage Un AC (V) 690
Dimension 000
Applicable standards IEC
Power loss (W) 17
Rated Voltage Un DC (V) 700
Time costant L/R (ms) 2
Series name NR2A
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 750
Fuse Connection/Terminal type Screw fixing
Fixing connection centres (mm) 80
Voltage of total clearing I2t test 700
Total clearing I²t @Un AC (A²s) 2800
Rated breaking capacity I1 AC (kA) 200000
Price List €44.91/pc
Quantity

NRAB - Fuse 690V AC aR NH00 with indicator 80A

Reference 341.251.07.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 80
Rated Voltage Un AC (V) 690
Dimension NH00
Applicable standards IEC
Power loss (W) 17
Series name NRAB
Melting I²t value (A²s) 750
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 770
Total clearing I²t @Un AC (A²s) 3600
Rated breaking capacity I1 AC (kA) 200000
Product available on request Ask for more information

NR2B - Fuse 00/80 aR 700VDC/690VAC with ind. w/o lug 25A

Reference 352.831.93.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 25
Rated Voltage Un AC (V) 690
Dimension 000
Applicable standards IEC, UL
Power loss (W) 4.6
Rated Voltage Un DC (V) 700
Time costant L/R (ms) 2
Series name NR2B
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 55
Fuse Connection/Terminal type Screw fixing
Fixing connection centres (mm) 80
Voltage of total clearing I2t test 700
Total clearing I²t @Un AC (A²s) 200
Rated breaking capacity I1 AC (kA) 200000
Product available on request Ask for more information

RL12 - Fuse 25x60mm 125VDC 400A

Reference 353.953.69.0.0 - Manufacturer FAULTRAP
Rated current In (A) 400
Power loss (W) 33
Rated Voltage Un DC (V) 125
Time costant L/R (ms) 3
Series name RL12
Rated breaking capacity I1 DC (kA) 10000
Melting I²t value (A²s) 21000
Total clearing I²t @Un AC (A²s) 170000
Price List €7.48/pc
Quantity

UR22 - Fuse 690V AC 22x58 cylindrical 32A

Reference 355.124.10.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 32
Rated Voltage Un AC (V) 550
Applicable standards IEC, UL
Power loss (W) 9
Series name UR22
Fuse Dimension (mm) 22x58
Melting I²t value (A²s) 65
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 550
Total clearing I²t @Un AC (A²s) 330
Rated breaking capacity I1 AC (kA) 200000
Price List €12.72/pc
Quantity

UR22 - Fuse 690V AC 22x58 fixing 80mm 20A

Reference 356.896.34.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 20
Rated Voltage Un AC (V) 690
Applicable standards IEC
Power loss (W) 6,1
Series name UR22
Fuse Dimension (mm) 22x58
Melting I²t value (A²s) 21
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 96
Rated breaking capacity I1 AC (kA) 200000
Product available on request Ask for more information

RL12 - Fuse 25x60mm 125VDC 100A

Reference 360.260.90.0.0 - Manufacturer FAULTRAP
Rated current In (A) 100
Power loss (W) 8,9
Rated Voltage Un DC (V) 125
Time costant L/R (ms) 3
Series name RL12
Rated breaking capacity I1 DC (kA) 10000
Melting I²t value (A²s) 1300
Total clearing I²t @Un AC (A²s) 12000
Price List €4.18/pc
Quantity

UR22 - Fuse 500V AC 22x58 fixing on pcb 150A

Reference 361.190.77.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 150
Rated Voltage Un AC (V) 500
Applicable standards IEC
Power loss (W) 31,9
Series name UR22
Fuse Dimension (mm) 22x58
Melting I²t value (A²s) 4850
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 23500
Rated breaking capacity I1 AC (kA) 200000
Product available on request Ask for more information

NR2A-Fuse 000/80 aR 700VDC/690VAC with ind. w/o lug 180A

Reference 367.466.71.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 180
Rated Voltage Un AC (V) 690
Dimension 000
Applicable standards IEC
Power loss (W) 42,5
Rated Voltage Un DC (V) 700
Time costant L/R (ms) 2
Series name NR2A
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 4120
Fuse Connection/Terminal type Screw fixing
Fixing connection centres (mm) 80
Voltage of total clearing I2t test 700
Total clearing I²t @Un AC (A²s) 15100
Rated breaking capacity I1 AC (kA) 200000
Product available on request Ask for more information

NR2A - Fuse DIN000 80mm aR 700VDC/690VAC with ind. lug 40A

Reference 373.304.38.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 40
Rated Voltage Un AC (V) 690
Dimension 000
Applicable standards IEC
Power loss (W) 7,2
Rated Voltage Un DC (V) 700
Time costant L/R (ms) 2
Series name NR2A
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 230
Fuse Connection/Terminal type Screw fixing
Fixing connection centres (mm) 80
Voltage of total clearing I2t test 700
Total clearing I²t @Un AC (A²s) 840
Rated breaking capacity I1 AC (kA) 200000
Product available on request Ask for more information

NR2B - Fuse 00/80 aR 700VDC/690VAC with ind. w/o lug 160A

Reference 382.074.88.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 160
Rated Voltage Un AC (V) 690
Dimension 000
Applicable standards IEC, UL
Power loss (W) 37.5
Rated Voltage Un DC (V) 700
Time costant L/R (ms) 2
Series name NR2B
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 3020
Fuse Connection/Terminal type Screw fixing
Fixing connection centres (mm) 80
Voltage of total clearing I2t test 700
Total clearing I²t @Un AC (A²s) 11100
Rated breaking capacity I1 AC (kA) 200000
Product available on request Ask for more information

NRAB - Fuse 690V AC aR NH00 with indicator 40A

Reference 383.177.16.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 40
Rated Voltage Un AC (V) 690
Dimension NH00
Applicable standards IEC
Power loss (W) 7,2
Series name NRAB
Melting I²t value (A²s) 230
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 770
Total clearing I²t @Un AC (A²s) 1100
Rated breaking capacity I1 AC (kA) 200000
Product available on request Ask for more information

UR22 - Fuse 690V AC 22x58 cylindrical 50A

Reference 384.770.34.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 50
Rated Voltage Un AC (V) 550
Applicable standards IEC, UL
Power loss (W) 13,3
Series name UR22
Fuse Dimension (mm) 22x58
Melting I²t value (A²s) 195
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 550
Total clearing I²t @Un AC (A²s) 955
Rated breaking capacity I1 AC (kA) 200000
Product available on request Ask for more information

NR2A - Fuse DIN000 80mm aR 700VDC/690VAC with ind. lug 63A

Reference 385.249.54.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 63
Rated Voltage Un AC (V) 690
Dimension 000
Applicable standards IEC
Power loss (W) 9.5
Rated Voltage Un DC (V) 700
Time costant L/R (ms) 2
Series name NR2A
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 520
Fuse Connection/Terminal type Screw fixing
Fixing connection centres (mm) 80
Voltage of total clearing I2t test 700
Total clearing I²t @Un AC (A²s) 1900
Rated breaking capacity I1 AC (kA) 200000
Price List €43.56/pc
Quantity

UR22 - Fuse 690V AC 22x58 cylindrical 63A

Reference 394.522.47.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 63
Rated Voltage Un AC (V) 550
Applicable standards IEC, UL
Power loss (W) 13,4
Series name UR22
Fuse Dimension (mm) 22x58
Melting I²t value (A²s) 540
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 550
Total clearing I²t @Un AC (A²s) 2370
Rated breaking capacity I1 AC (kA) 200000
Price List €16.88/pc
Quantity

UR22 - Fuse 690V AC 22x58 cylindrical 25A

Reference 399.213.34.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 25
Rated Voltage Un AC (V) 550
Applicable standards IEC, UL
Power loss (W) 7,6
Series name UR22
Fuse Dimension (mm) 22x58
Melting I²t value (A²s) 33
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 550
Total clearing I²t @Un AC (A²s) 147
Rated breaking capacity I1 AC (kA) 200000
Product available on request Ask for more information
Product added to compare.
Product added to wishlist