Fuse 8x32 gG 400V with indicator 2A

Reference 420602.0.0 - Manufacturer DF
Class gG
Rated current In (A) 2
Rated Voltage Un AC (V) 400
Applicable standards IEC
Power loss (W) 0,5
Fuse Dimension (mm) 8x32
Melting I²t value (A²s) 7
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 400
Total clearing I²t @Un AC (A²s) 14,6
Rated breaking capacity I1 AC (kA) 20000
Weight (gr) 4
Price List €1.31/pc
Quantity

Fuse VT 7,2kV 39,6x220 4A

Reference 3037111.4.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 4
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Power loss (W) 7,4
Fuse Dimension (mm) 40x220
Melting I²t value (A²s) 28,9
Fuse Connection/Terminal type BS
Voltage of total clearing I2t test 7200
Total clearing I²t @Un AC (A²s) 85,3
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2000
Price List €64.07/pc
Quantity

Fuse VT 12kV 39,6x220 0,5A

Reference 3037211.0,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 0,5
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 3,3
Fuse Dimension (mm) 40x220
Melting I²t value (A²s) 0,1
Fuse Connection/Terminal type BS
Voltage of total clearing I2t test 12000
Total clearing I²t @Un AC (A²s) 0,9
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 680
Price List €269.12/pc
Quantity

Fuse VT 12kV 39,6x220 1A

Reference 3037211.1.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 1
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 5.3
Fuse Dimension (mm) 40x220
Melting I²t value (A²s) 0,6
Fuse Connection/Terminal type BS
Voltage of total clearing I2t test 12000
Total clearing I²t @Un AC (A²s) 1,9
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 680
Price List €69.39/pc
Quantity

Fuse VT 17,5kV 39,6x340 0,5A

Reference 3037311.0,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 0,5
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 4,4
Fuse Dimension (mm) 40x340
Melting I²t value (A²s) 0,1
Fuse Connection/Terminal type BS
Voltage of total clearing I2t test 17500
Total clearing I²t @Un AC (A²s) 0,9
Rated breaking capacity I1 AC (kA) 36000
Weight (gr) 840
Price List €64.74/pc
Quantity

Fuse TV 17,5kV 39,6x220 0,5A

Reference 3044411.0,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 0,5
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 4,4
Fuse Dimension (mm) 40x220
Melting I²t value (A²s) 0,1
Fuse Connection/Terminal type BS
Voltage of total clearing I2t test 17500
Total clearing I²t @Un AC (A²s) 0,9
Rated breaking capacity I1 AC (kA) 36000
Weight (gr) 700
Product available on request Ask for more information

Fuse NH2 aM 500V double indicator 400A

Reference 383380.0.0 - Manufacturer DF
Class aM
Rated current In (A) 400
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC
Power loss (W) 27,8
Melting I²t value (A²s) 502000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 1308183
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 710
Price List €22.47/pc
Quantity

Fuse 17,5kV 53x292 back-up without striker 2,5A

Reference 3025511.2,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 2,5
Rated Voltage Un AC (V) 17500
Fuse Dimension (mm) 53x292
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 1640
Product available on request Ask for more information

Fuse 17,5kV 53x292 back-up without striker 4A

Reference 3025511.4.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 4
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Fuse Dimension (mm) 53x292
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 1640
Product available on request Ask for more information

Fuse 17,5kV 53x292 back-up without striker 5A

Reference 3025511.5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 5
Rated Voltage Un AC (V) 17500
Fuse Dimension (mm) 53x292
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 1640
Product available on request Ask for more information

Fuse DIN Motors 12kV 53x442 with striker 25A 80N

Reference 3010153.25.0 - Manufacturer SIBA
Class HH Motors
Rated current In (A) 25
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 34
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 730
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 12000
Total clearing I²t @Un AC (A²s) 5500
Rated breaking capacity I1 AC (kA) 63000
Price List €133.35/pc
Quantity

Fuse DIN Motors 12kV 53x442 with striker 31,5A 80N

Reference 3010153.31,5.0 - Manufacturer SIBA
Class HH Motors
Rated current In (A) 31,5
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 39
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 1300
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 12000
Total clearing I²t @Un AC (A²s) 9100
Rated breaking capacity I1 AC (kA) 63000
Price List €130.71/pc
Quantity

Fuse 17,5kV 53x367 back-up without striker 2,5A

Reference 3017611.2,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 2,5
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 12
Resistance (ohm) 1,4
Fuse Dimension (mm) 53x367
Melting I²t value (A²s) 7,2
Minimum breaking current (A) 20
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 24
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2010
Price List €42.08/pc
Quantity

Fuse 17,5kV 53x367 back-up without striker 4A

Reference 3017611.4.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 4
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 16
Resistance (ohm) 0,69
Fuse Dimension (mm) 53x367
Melting I²t value (A²s) 31
Minimum breaking current (A) 32
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 90
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2000
Price List €48.60/pc
Quantity

Fuse 17,5kV 53x367 back-up with striker 2,5A 80N

Reference 3017613.2,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 2,5
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 12
Resistance (ohm) 1,4
Fuse Dimension (mm) 53x367
Melting I²t value (A²s) 7,2
Minimum breaking current (A) 20
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 24
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 1980
Product available on request Ask for more information

Fuse 17,5kV 53x367 back-up with striker 5A 80N

Reference 3017613.5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 5
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 11
Resistance (ohm) 0,314
Fuse Dimension (mm) 53x367
Melting I²t value (A²s) 40
Minimum breaking current (A) 40
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 125
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 1980
Price List €46.00/pc
Quantity

Fuse 12kV 53x442 back-up 0,5A

Reference 3010111.0,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 0,5
Rated Voltage Un AC (V) 6000
Applicable standards IEC
Power loss (W) 6,1
Resistance (ohm) 22,13
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 1,6
Minimum breaking current (A) 5
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 5220
Total clearing I²t @Un AC (A²s) 5,9
Rated breaking capacity I1 AC (kA) 63000
Product available on request Ask for more information

Fuse 12kV 53x442 back-up 1A

Reference 3010111.1.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 1
Rated Voltage Un AC (V) 6000
Applicable standards IEC
Power loss (W) 4,8
Resistance (ohm) 3,51
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 0,63
Minimum breaking current (A) 8
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 5220
Total clearing I²t @Un AC (A²s) 2,8
Rated breaking capacity I1 AC (kA) 63000
Product available on request Ask for more information

Fuse 12kV 53x442 back-up with striker 2,5A 80N

Reference 3010113.2,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 2,5
Rated Voltage Un AC (V) 6000
Applicable standards IEC
Power loss (W) 8,9
Resistance (ohm) 0,95
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 7,2
Minimum breaking current (A) 20
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 5220
Total clearing I²t @Un AC (A²s) 23
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2300
Product available on request Ask for more information

Fuse 12kV 53x442 back-up with striker 4A 80N

Reference 3010113.4.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 4
Rated Voltage Un AC (V) 6000
Applicable standards IEC
Power loss (W) 12
Resistance (ohm) 0,52
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 31
Minimum breaking current (A) 32
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 5220
Total clearing I²t @Un AC (A²s) 90
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2300
Product available on request Ask for more information

Fuse 12kV 53x442 back-up with striker 5A 80N

Reference 3010113.5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 5
Rated Voltage Un AC (V) 6000
Applicable standards IEC
Power loss (W) 8,3
Resistance (ohm) 0,236
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 40
Minimum breaking current (A) 40
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 5220
Total clearing I²t @Un AC (A²s) 125
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2300
Product available on request Ask for more information

Fuse 7,2kV 53x192 back-up without striker 4A

Reference 3000211.4.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 4
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Power loss (W) 7,2
Resistance (ohm) 0,31
Fuse Dimension (mm) 53x192
Melting I²t value (A²s) 31
Minimum breaking current (A) 32
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 6264
Total clearing I²t @Un AC (A²s) 90
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 1200
Price List €44.81/pc
Quantity

Fuse SMD + holder 4,5x16 T 250V UL 1A

Reference 160516.1.0 - Manufacturer SIBA
Class T
Rated current In (A) 1
Rated Voltage Un AC (V) 250
Applicable standards IEC, UL
Power loss (W) 490
Voltage drop (mV) 380
Fuse Dimension (mm) 4,5x16
Melting I²t value (A²s) 4,5
Fuse Connection/Terminal type SMD
Voltage of total clearing I2t test 250
Rated breaking capacity I1 AC (kA) 1500
Weight (gr) 2
Product available on request Ask for more information

Fuse SMD + holder 4,5x16 T 250V UL 10A

Reference 160516.10.0 - Manufacturer SIBA
Class T
Rated current In (A) 10
Rated Voltage Un AC (V) 250
Applicable standards IEC, UL
Power loss (W) 1500
Voltage drop (mV) 80
Fuse Dimension (mm) 4,5x16
Melting I²t value (A²s) 280
Fuse Connection/Terminal type SMD
Voltage of total clearing I2t test 250
Rated breaking capacity I1 AC (kA) 1500
Weight (gr) 2
Product available on request Ask for more information
Filter by
Manufacturer
Series name
Fuse size
Class
Fuse Connection/Terminal type
Rated current In (A)
Rated Voltage Un AC (V)
Rated Voltage Un DC (V)
Applicable standards
Product added to compare.
Product added to wishlist