Fuses

Fuse 7,2kV 85x292 back-up striker no temp.lim200ARC160

Reference 3010014.200.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 200
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Power loss (W) 80
Resistance (ohm) 0,0018
Fuse Dimension (mm) 85x292
Melting I²t value (A²s) 266000
Minimum breaking current (A) 800
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 6264
Total clearing I²t @Un AC (A²s) 1150000
Rated breaking capacity I1 AC (kA) 80000
Weight (gr) 3870
Price List €644.34/pc
Quantity

Fuse 7,2kV 85x292 back-up striker no temp.lim250ARC180

Reference 3010014.250.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 250
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Power loss (W) 65
Resistance (ohm) 0,0015
Fuse Dimension (mm) 85x292
Melting I²t value (A²s) 405000
Minimum breaking current (A) 1000
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 6264
Total clearing I²t @Un AC (A²s) 1600000
Rated breaking capacity I1 AC (kA) 80000
Weight (gr) 3870
Price List €382.60/pc
Quantity

Fuse 7,2kV 87x292 back-up striker no temp.lim315ARC200

Reference 3010014.315LM.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 315
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Power loss (W) 76
Resistance (ohm) 0,0013
Fuse Dimension (mm) 85x292
Melting I²t value (A²s) 551000
Minimum breaking current (A) 1250
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 6264
Total clearing I²t @Un AC (A²s) 2200000
Rated breaking capacity I1 AC (kA) 80000
Price List €690.60/pc
Quantity

Fuse 7,2kV 87x292 back-up striker no temp.lim355ARC225

Reference 3010014.355LM.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 355
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Power loss (W) 76
Resistance (ohm) 0,0011
Fuse Dimension (mm) 85x292
Melting I²t value (A²s) 794000
Minimum breaking current (A) 1370
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 6264
Total clearing I²t @Un AC (A²s) 3700000
Rated breaking capacity I1 AC (kA) 80000
Weight (gr) 3870
Price List €751.98/pc
Quantity

Fuse NH0 690V gG 16A

Reference 3010016.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 16
Rated Voltage Un AC (V) 690
Dimension NH0
Applicable standards IEC
Power loss (W) 1,5
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 260
Product available on request Ask for more information

Fuse NH0 690V gG 20A

Reference 3010020.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 20
Rated Voltage Un AC (V) 690
Dimension NH0
Applicable standards IEC
Power loss (W) 1,6
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 260
Product available on request Ask for more information

Fuse NH0 690V gG 25A

Reference 3010025.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 25
Rated Voltage Un AC (V) 690
Dimension NH0
Applicable standards IEC
Power loss (W) 2
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 260
Product available on request Ask for more information

Fuse NH0 690V gG 32A

Reference 3010032.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 32
Rated Voltage Un AC (V) 690
Dimension NH0
Applicable standards IEC
Power loss (W) 3
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 260
Product available on request Ask for more information

Fuse NH0 690V gG 35A

Reference 3010035.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 35
Rated Voltage Un AC (V) 690
Dimension NH0
Applicable standards IEC
Power loss (W) 3,1
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 260
Product available on request Ask for more information

Fuse NH0 690V gG 40A

Reference 3010040.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 40
Rated Voltage Un AC (V) 690
Dimension NH0
Applicable standards IEC
Power loss (W) 3,2
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 260
Product available on request Ask for more information

Fuse NH0 690V gG 50A

Reference 3010050.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 50
Rated Voltage Un AC (V) 690
Dimension NH0
Applicable standards IEC
Power loss (W) 3,2
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 260
Product available on request Ask for more information

Fuse NH0 690V gG 63A

Reference 3010063.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 63
Rated Voltage Un AC (V) 690
Dimension NH0
Applicable standards IEC
Power loss (W) 4,2
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 260
Product available on request Ask for more information

Fuse NH0 690V gG 80A

Reference 3010080.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 80
Rated Voltage Un AC (V) 690
Dimension NH0
Applicable standards IEC
Power loss (W) 5,2
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 260
Product available on request Ask for more information

Fuse NH0 690V gG 100A

Reference 3010100.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 100
Rated Voltage Un AC (V) 690
Dimension NH0
Applicable standards IEC
Power loss (W) 6,5
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 260
Product available on request Ask for more information

Fuse 12kV 53x442 back-up 0,5A

Reference 3010111.0,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 0,5
Rated Voltage Un AC (V) 6000
Applicable standards IEC
Power loss (W) 6,1
Resistance (ohm) 22,13
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 1,6
Minimum breaking current (A) 5
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 5220
Total clearing I²t @Un AC (A²s) 5,9
Rated breaking capacity I1 AC (kA) 63000
Product available on request Ask for more information

Fuse 12kV 53x442 back-up 1A

Reference 3010111.1.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 1
Rated Voltage Un AC (V) 6000
Applicable standards IEC
Power loss (W) 4,8
Resistance (ohm) 3,51
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 0,63
Minimum breaking current (A) 8
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 5220
Total clearing I²t @Un AC (A²s) 2,8
Rated breaking capacity I1 AC (kA) 63000
Product available on request Ask for more information

Fuse 12kV 53x442 back-up with striker 10A 80N

Reference 3010113.10.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 10
Rated Voltage Un AC (V) 6000
Applicable standards IEC
Power loss (W) 25
Resistance (ohm) 0,189
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 68
Minimum breaking current (A) 34
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 5220
Total clearing I²t @Un AC (A²s) 1260
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2300
Price List €246.49/pc
Quantity

Fuse 12kV 53x442 back-up with striker 16A 80N

Reference 3010113.16.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 16
Rated Voltage Un AC (V) 6000
Applicable standards IEC
Power loss (W) 29
Resistance (ohm) 0,092
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 140
Minimum breaking current (A) 56
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 5220
Total clearing I²t @Un AC (A²s) 2360
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2300
Price List €247.76/pc
Quantity

Fuse 12kV 53x442 back-up with striker 2,5A 80N

Reference 3010113.2,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 2,5
Rated Voltage Un AC (V) 6000
Applicable standards IEC
Power loss (W) 8,9
Resistance (ohm) 0,95
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 7,2
Minimum breaking current (A) 20
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 5220
Total clearing I²t @Un AC (A²s) 23
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2300
Product available on request Ask for more information

Fuse 12kV 53x442 back-up with striker 2A 80N

Reference 3010113.2.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 2
Rated Voltage Un AC (V) 6000
Applicable standards IEC
Power loss (W) 8.2
Resistance (ohm) 1,57
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 3,2
Minimum breaking current (A) 16
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 5220
Total clearing I²t @Un AC (A²s) 9,8
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2300
Price List €207.50/pc
Quantity

Fuse 12kV 53x442 back-up with striker 20A 80N

Reference 3010113.20.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 20
Rated Voltage Un AC (V) 6000
Applicable standards IEC
Power loss (W) 21
Resistance (ohm) 0,047
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 545
Minimum breaking current (A) 70
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 5220
Total clearing I²t @Un AC (A²s) 4200
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2300
Price List €249.66/pc
Quantity

Fuse 12kV 53x442 back-up with striker 25A 80N

Reference 3010113.25.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 25
Rated Voltage Un AC (V) 6000
Applicable standards IEC
Power loss (W) 33
Resistance (ohm) 0,036
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 920
Minimum breaking current (A) 90
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 5220
Total clearing I²t @Un AC (A²s) 7100
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2300
Price List €250.82/pc
Quantity

Fuse 12kV 53x442 back-up with striker 3,15A 80N

Reference 3010113.3,15.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 3,15
Rated Voltage Un AC (V) 6000
Applicable standards IEC
Power loss (W) 9,6
Resistance (ohm) 0,7
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 17
Minimum breaking current (A) 24
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 5220
Total clearing I²t @Un AC (A²s) 48
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2300
Price List €207.59/pc
Quantity

Fuse 12kV 53x442 back-up with striker 31,5A 80N

Reference 3010113.31,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 31,5
Rated Voltage Un AC (V) 6000
Applicable standards IEC
Power loss (W) 37
Resistance (ohm) 0,029
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 1400
Minimum breaking current (A) 110
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 5220
Total clearing I²t @Un AC (A²s) 10800
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2300
Price List €311.28/pc
Quantity
Filter by
Manufacturer
Series name
Fuse size
Class
Fuse Connection/Terminal type
Rated current In (A)
Rated Voltage Un AC (V)
Rated Voltage Un DC (V)
Applicable standards
Product added to compare.
Product added to wishlist