List of products by manufacturer SIBA

Fuse 7,2kV 53x292 TV with striker 2,5A 80N

Reference 3009813.2,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 2,5
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Power loss (W) 5,2
Resistance (ohm) 0,63
Fuse Dimension (mm) 53x292
Melting I²t value (A²s) 7,2
Minimum breaking current (A) 20
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 6264
Total clearing I²t @Un AC (A²s) 22
Rated breaking capacity I1 AC (kA) 80000
Product available on request Ask for more information

Fuse 7,2kV 53x292 back-up with striker 16A 80N

Reference 3009813.16.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 16
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Power loss (W) 19
Resistance (ohm) 0,055
Fuse Dimension (mm) 53x292
Melting I²t value (A²s) 140
Minimum breaking current (A) 56
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 6264
Total clearing I²t @Un AC (A²s) 1250
Rated breaking capacity I1 AC (kA) 80000
Weight (gr) 1700
Price List €600.54/pc
Quantity

Fuse 7,2kV 53x292 back-up with striker 10A 80N

Reference 3009813.10.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 10
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Power loss (W) 15
Resistance (ohm) 0,115
Fuse Dimension (mm) 53x292
Melting I²t value (A²s) 68
Minimum breaking current (A) 34
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 6264
Total clearing I²t @Un AC (A²s) 600
Rated breaking capacity I1 AC (kA) 80000
Weight (gr) 1580
Price List €233.46/pc
Quantity

Fuse 7,2kV 53x292 TV 1A

Reference 3009811.1.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 1
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Power loss (W) 2,8
Resistance (ohm) 2,1
Fuse Dimension (mm) 53x292
Melting I²t value (A²s) 0,63
Minimum breaking current (A) 8
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 6264
Total clearing I²t @Un AC (A²s) 2,8
Rated breaking capacity I1 AC (kA) 80000
Weight (gr) 1600
Product available on request Ask for more information

Fuse 7,2kV 53x292 TV 0,5A

Reference 3009811.0,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 0,5
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Power loss (W) 3,6
Resistance (ohm) 13,25
Fuse Dimension (mm) 53x292
Melting I²t value (A²s) 1,6
Minimum breaking current (A) 5
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 6264
Total clearing I²t @Un AC (A²s) 5,9
Rated breaking capacity I1 AC (kA) 80000
Weight (gr) 1600
Price List €387.22/pc
Quantity

Fuse 36kV 85x537 back-up 80A with striker 120N

Reference 3002414.80.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 80
Rated Voltage Un AC (V) 36000
Applicable standards IEC
Power loss (W) 145
Resistance (ohm) 23
Fuse Dimension (mm) 85x537
Melting I²t value (A²s) 17000
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 36000
Total clearing I²t @Un AC (A²s) 171000
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 6730
Price List €1,152.78/pc
Quantity

Fuse 12kV 85x292 general purpose with striker 100A 80N

Reference 3002093.100.0 - Manufacturer SIBA
Class HH G P
Rated current In (A) 100
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 108
Resistance (ohm) 7,7
Fuse Dimension (mm) 85x292
Melting I²t value (A²s) 23500
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 12000
Total clearing I²t @Un AC (A²s) 183000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 3880
Price List €559.64/pc
Quantity

Fuse 12kV 85x292 general purpose with striker 50A 80N

Reference 3002093.50.0 - Manufacturer SIBA
Class HH G P
Rated current In (A) 50
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 42
Resistance (ohm) 15
Fuse Dimension (mm) 85x292
Melting I²t value (A²s) 5500
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 12000
Total clearing I²t @Un AC (A²s) 33000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 3880
Price List €456.59/pc
Quantity

Fuse 12kV 85x292 general purpose with striker 63A 80N

Reference 3002093.63.0 - Manufacturer SIBA
Class HH G P
Rated current In (A) 63
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 54
Resistance (ohm) 12
Fuse Dimension (mm) 85x292
Melting I²t value (A²s) 8500
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 12000
Total clearing I²t @Un AC (A²s) 68000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 3880
Price List €488.85/pc
Quantity

Fuse 12kV 85x292 general purpose with striker 80A 80N

Reference 3002093.80.0 - Manufacturer SIBA
Class HH G P
Rated current In (A) 80
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 79
Resistance (ohm) 9
Fuse Dimension (mm) 85x292
Melting I²t value (A²s) 16200
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 12000
Total clearing I²t @Un AC (A²s) 142000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 3880
Price List €511.94/pc
Quantity

Fuse 24kV 85x442 back-up with striker 100ARC85 80N

Reference 3002213.100.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 100
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 141
Resistance (ohm) 0,013
Fuse Dimension (mm) 85x442
Melting I²t value (A²s) 28000
Minimum breaking current (A) 320
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 20880
Total clearing I²t @Un AC (A²s) 254000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 5760
Price List €181.92/pc
Quantity

Fuse 24kV 85x442 back-up with striker 125ARC90 80N

Reference 3002213.125.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 125
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 136
Resistance (ohm) 0,011
Fuse Dimension (mm) 85x442
Melting I²t value (A²s) 38400
Minimum breaking current (A) 390
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 20880
Total clearing I²t @Un AC (A²s) 348000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 5720
Price List €257.93/pc
Quantity

Fuse 24kV 85x442 back-up with striker 160ARC105 80N

Reference 3002213.160.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 160
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 146
Resistance (ohm) 0,0088
Fuse Dimension (mm) 85x442
Melting I²t value (A²s) 62000
Minimum breaking current (A) 600
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 20880
Total clearing I²t @Un AC (A²s) 378000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 5700
Price List €531.40/pc
Quantity

Fuse 24kV 85x442 striker no temp-limiting 100ARC85 120N

Reference 3002214.100.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 100
Rated Voltage Un AC (V) 24000
Power loss (W) 234
Resistance (ohm) 13
Fuse Dimension (mm) 85x442
Melting I²t value (A²s) 33000
Minimum breaking current (A) 320
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 210000
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 5710
Price List €229.29/pc
Quantity

Fuse 24kV 85x442 striker no temp-limiting 160A 120N

Reference 3002214.160.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 160
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Fuse Dimension (mm) 85x442
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 20880
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 5600
Price List €545.58/pc
Quantity

Fuse 24kV 87x442 striker no temp.lim 200ARC112 120N

Reference 3002214.200.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 200
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 172
Resistance (ohm) 0,0093
Fuse Dimension (mm) 87x442
Melting I²t value (A²s) 75000
Minimum breaking current (A) 800
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 20880
Total clearing I²t @Un AC (A²s) 313000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 6320
Price List €574.92/pc
Quantity

Fuse 24kV 87x442 striker no temp.lim 250ARC125 120N

Reference 3002214.250LM.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 250
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 142
Resistance (ohm) 0,006
Fuse Dimension (mm) 85x442
Melting I²t value (A²s) 179000
Minimum breaking current (A) 1000
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 20880
Total clearing I²t @Un AC (A²s) 803000
Rated breaking capacity I1 AC (kA) 63000
Price List €595.57/pc
Quantity

Fuse 24 kV 85x442 SSK with striker 100A 80N

Reference 3002243.100.0 - Manufacturer SIBA
Class HH SSK
Rated current In (A) 100
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 188
Resistance (ohm) 12
Fuse Dimension (mm) 85x442
Melting I²t value (A²s) 22300
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 136000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 5820
Price List €393.24/pc
Quantity

Fuse 24 kV 85x442 SSK with striker 125A 80N

Reference 3002243.125.0 - Manufacturer SIBA
Class HH SSK
Rated current In (A) 125
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 277
Resistance (ohm) 10
Fuse Dimension (mm) 85x442
Melting I²t value (A²s) 30300
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 248000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 5820
Price List €433.60/pc
Quantity

Fuse 36kV 85x537 SSK with striker 50A 80N

Reference 3002443.50.0 - Manufacturer SIBA
Class HH SSK
Rated current In (A) 50
Rated Voltage Un AC (V) 36000
Applicable standards IEC
Power loss (W) 132
Fuse Dimension (mm) 85x537
Melting I²t value (A²s) 6200
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 21000
Total clearing I²t @Un AC (A²s) 49000
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 6800
Price List €278.89/pc
Quantity

Fuse 36kV 85x537 back-up 63A with striker 120N

Reference 3002414.63.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 63
Rated Voltage Un AC (V) 36000
Applicable standards IEC
Power loss (W) 255
Resistance (ohm) 35
Fuse Dimension (mm) 85x537
Melting I²t value (A²s) 8700
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 36000
Total clearing I²t @Un AC (A²s) 88000
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 6730
Price List €211.72/pc
Quantity

Fuse 24 kV 85x442 SSK with striker 140A 80N

Reference 3002243.140.0 - Manufacturer SIBA
Class HH SSK
Rated current In (A) 140
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 155
Resistance (ohm) 8
Fuse Dimension (mm) 85x442
Melting I²t value (A²s) 51000
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 350000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 5820
Price List €356.15/pc
Quantity

Fuse 24kV 85x442 general purpose with striker 31,5A 80N

Reference 3002293.31,5.0 - Manufacturer SIBA
Class HH G P
Rated current In (A) 31,5
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 54
Resistance (ohm) 41
Fuse Dimension (mm) 85x442
Melting I²t value (A²s) 2100
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 18000
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 5600
Price List €520.48/pc
Quantity
Product added to compare.
Product added to wishlist