All Products

Fuse VT 36kV 24x359mm (BC..) 2A

Reference 3038111.2.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 2
Rated Voltage Un AC (V) 36000
Power loss (W) 24
Fuse Dimension (mm) 24x359
Melting I²t value (A²s) 3,2
Fuse Connection/Terminal type BS
Voltage of total clearing I2t test 36000
Total clearing I²t @Un AC (A²s) 9,9
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 386
Price List €131.98/pc
Quantity

Fuse VT 36kV 24x359 3A

Reference 3038111.3.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 3
Rated Voltage Un AC (V) 36000
Applicable standards IEC
Power loss (W) 28
Fuse Dimension (mm) 24x359
Melting I²t value (A²s) 16,1
Fuse Connection/Terminal type BS
Voltage of total clearing I2t test 36000
Total clearing I²t @Un AC (A²s) 47,8
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 386
Price List €132.37/pc
Quantity

Fuse VT 36kV DIN 53x292 0,5A

Reference 3038211.0,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 0,5
Rated Voltage Un AC (V) 36000
Applicable standards IEC
Power loss (W) 17
Resistance (ohm) 60,8
Fuse Dimension (mm) 53x292
Melting I²t value (A²s) 1,6
Minimum breaking current (A) 5
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 31320
Total clearing I²t @Un AC (A²s) 5,9
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 1800
Price List €543.06/pc
Quantity

Fuse VT 36kV DIN 53x292 1A

Reference 3038211.1.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 1
Rated Voltage Un AC (V) 36000
Applicable standards IEC
Power loss (W) 13
Resistance (ohm) 9,57
Fuse Dimension (mm) 53x292
Melting I²t value (A²s) 0,63
Minimum breaking current (A) 8
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 31320
Total clearing I²t @Un AC (A²s) 2,8
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 1640
Price List €96.55/pc
Quantity

Fuse VT 36kV DIN 53x292 2A

Reference 3038211.2.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 2
Rated Voltage Un AC (V) 36000
Applicable standards IEC
Power loss (W) 23
Resistance (ohm) 4,26
Fuse Dimension (mm) 53x292
Melting I²t value (A²s) 3,2
Minimum breaking current (A) 16
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 31320
Total clearing I²t @Un AC (A²s) 9,8
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 1640
Price List €96.93/pc
Quantity

Fuse VT 36kV DIN 53x292 3,15A

Reference 3038211.3,15.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 3,15
Rated Voltage Un AC (V) 36000
Applicable standards IEC
Power loss (W) 26
Resistance (ohm) 1,9
Fuse Dimension (mm) 53x292
Melting I²t value (A²s) 17
Minimum breaking current (A) 24
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 31320
Total clearing I²t @Un AC (A²s) 48
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 2000
Price List €97.27/pc
Quantity

Fuse VT 36kV DIN 53x292 with striker 2,5A 80N

Reference 3038213.2,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 2,5
Rated Voltage Un AC (V) 36000
Applicable standards IEC
Power loss (W) 22
Resistance (ohm) 2,6
Fuse Dimension (mm) 53x292
Melting I²t value (A²s) 7,2
Minimum breaking current (A) 20
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 31320
Total clearing I²t @Un AC (A²s) 23
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 1660
Price List €570.11/pc
Quantity

Fuse VT 36kV DIN 53x292 with striker 2A 80N

Reference 3038213.2.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 2
Rated Voltage Un AC (V) 36000
Applicable standards IEC
Power loss (W) 23
Resistance (ohm) 4,26
Fuse Dimension (mm) 53x292
Melting I²t value (A²s) 3,2
Minimum breaking current (A) 16
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 31320
Total clearing I²t @Un AC (A²s) 9,8
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 1660
Price List €570.11/pc
Quantity

Fuse VT 36kV DIN 53x292 with striker 3,15A 80N

Reference 3038213.3,15.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 3,15
Rated Voltage Un AC (V) 36000
Applicable standards IEC
Power loss (W) 26
Resistance (ohm) 1,9
Fuse Dimension (mm) 53x292
Melting I²t value (A²s) 17
Minimum breaking current (A) 24
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 31320
Total clearing I²t @Un AC (A²s) 48
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 1660
Price List €570.53/pc
Quantity

Fuse VT 36kV DIN 53x292 with striker 4A 80N

Reference 3038213.4.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 4
Rated Voltage Un AC (V) 36000
Applicable standards IEC
Power loss (W) 33
Resistance (ohm) 1,42
Fuse Dimension (mm) 53x292
Melting I²t value (A²s) 31
Minimum breaking current (A) 32
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 31320
Total clearing I²t @Un AC (A²s) 90
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 1660
Price List €570.98/pc
Quantity

Fuse VT 36kV DIN 53x292 with striker 5A 80N

Reference 3038213.5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 5
Rated Voltage Un AC (V) 36000
Applicable standards IEC
Power loss (W) 23
Resistance (ohm) 0,65
Fuse Dimension (mm) 53x292
Melting I²t value (A²s) 40
Minimum breaking current (A) 40
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 31320
Total clearing I²t @Un AC (A²s) 125
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 1680
Price List €570.57/pc
Quantity
Filter by
Manufacturer
Series name
Class
Rated Voltage Un AC (V)
Rated Voltage Un DC (V)
Rated insultaion voltage AC (V)
Rated insulated voltage DC (V)
Applicable standards
Product added to compare.
Product added to wishlist