All Products

Fuse 14x65 1500VDC gPV UL2579 10A

Reference 5024028.10.0 - Manufacturer SIBA
Class gPV
Rated current In (A) 10
Applicable standards IEC, UL
Power loss (W) 4
Rated Voltage Un DC (V) 1500
Time costant L/R (ms) 3
Rated breaking capacity I1 DC (kA) 30000
Fuse Dimension (mm) 14x65
Melting I²t value (A²s) 5
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 41
Weight (gr) 28
Price List €38.33/pc
Quantity

Fuse 14x65 1500VDC gPV UL2579 15A

Reference 5024028.15.0 - Manufacturer SIBA
Class gPV
Rated current In (A) 15
Applicable standards IEC, UL
Power loss (W) 4,5
Rated Voltage Un DC (V) 1500
Time costant L/R (ms) 1
Rated breaking capacity I1 DC (kA) 30000
Fuse Dimension (mm) 14x65
Melting I²t value (A²s) 21
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 170
Weight (gr) 28
Price List €19.11/pc
Quantity

Fuse 14x65 1500VDC gPV UL2579 16A

Reference 5024028.16.0 - Manufacturer SIBA
Class gPV
Rated current In (A) 16
Applicable standards IEC, UL
Power loss (W) 4,7
Rated Voltage Un DC (V) 1500
Time costant L/R (ms) 3
Rated breaking capacity I1 DC (kA) 30000
Fuse Dimension (mm) 14x65
Melting I²t value (A²s) 26
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 210
Weight (gr) 28
Price List €38.85/pc
Quantity

Fuse 14x65 1500VDC gPV UL2579 20A

Reference 5024028.20.0 - Manufacturer SIBA
Class gPV
Rated current In (A) 20
Applicable standards IEC, UL
Power loss (W) 5
Rated Voltage Un DC (V) 1500
Time costant L/R (ms) 3
Rated breaking capacity I1 DC (kA) 30000
Fuse Dimension (mm) 14x65
Melting I²t value (A²s) 66
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 540
Weight (gr) 27
Price List €37.15/pc
Quantity

Fuse 14x65 1500VDC gPV UL2579 25A

Reference 5024028.25.0 - Manufacturer SIBA
Class gPV
Rated current In (A) 25
Applicable standards IEC, UL
Power loss (W) 6
Rated Voltage Un DC (V) 1500
Time costant L/R (ms) 3
Rated breaking capacity I1 DC (kA) 30000
Fuse Dimension (mm) 14x65
Melting I²t value (A²s) 90
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 730
Weight (gr) 28
Price List €39.87/pc
Quantity

Fuse 14x65 1500VDC gPV UL2579 30A

Reference 5024028.30.0 - Manufacturer SIBA
Class gPV
Rated current In (A) 30
Applicable standards IEC, UL
Power loss (W) 7
Rated Voltage Un DC (V) 1500
Time costant L/R (ms) 3
Rated breaking capacity I1 DC (kA) 30000
Fuse Dimension (mm) 14x65
Melting I²t value (A²s) 149
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 1350
Weight (gr) 28
Price List €40.44/pc
Quantity

Fuse 14x65 with bolted contats 1500VDC gPV UL2579 10A

Reference 5024228.10.0 - Manufacturer SIBA
Class gPV
Rated current In (A) 10
Applicable standards IEC, UL
Power loss (W) 4
Rated Voltage Un DC (V) 1500
Time costant L/R (ms) 3
Rated breaking capacity I1 DC (kA) 30000
Fuse Dimension (mm) 14x65
Melting I²t value (A²s) 5
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 41
Weight (gr) 38
Price List €359.01/pc
Quantity

Fuse 14x65 with bolted contats 1500VDC gPV UL2579 12A

Reference 5024228.12.0 - Manufacturer SIBA
Class gPV
Rated current In (A) 12
Applicable standards IEC, UL
Power loss (W) 4,2
Rated Voltage Un DC (V) 1500
Time costant L/R (ms) 3
Rated breaking capacity I1 DC (kA) 30000
Fuse Dimension (mm) 14x65
Melting I²t value (A²s) 12
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 100
Weight (gr) 38
Price List €359.21/pc
Quantity

Fuse 14x65 with bolted contats 1500VDC gPV UL2579 16A

Reference 5024228.16.0 - Manufacturer SIBA
Class gPV
Rated current In (A) 16
Applicable standards IEC, UL
Power loss (W) 4,7
Rated Voltage Un DC (V) 1500
Time costant L/R (ms) 3
Rated breaking capacity I1 DC (kA) 30000
Fuse Dimension (mm) 14x65
Melting I²t value (A²s) 26
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 210
Weight (gr) 38
Price List €357.56/pc
Quantity

Fuse 14x65 with bolted contats 1500VDC gPV UL2579 20A

Reference 5024228.20.0 - Manufacturer SIBA
Class gPV
Rated current In (A) 20
Applicable standards IEC, UL
Power loss (W) 5
Rated Voltage Un DC (V) 1500
Time costant L/R (ms) 3
Rated breaking capacity I1 DC (kA) 30000
Fuse Dimension (mm) 14x65
Melting I²t value (A²s) 66
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 540
Weight (gr) 38
Price List €358.22/pc
Quantity

Fuse 14x65 with bolted contats 1500VDC gPV UL2579 25A

Reference 5024228.25.0 - Manufacturer SIBA
Class gPV
Rated current In (A) 25
Applicable standards IEC, UL
Power loss (W) 6
Rated Voltage Un DC (V) 1500
Time costant L/R (ms) 3
Rated breaking capacity I1 DC (kA) 30000
Fuse Dimension (mm) 14x65
Melting I²t value (A²s) 90
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 730
Weight (gr) 38
Price List €358.63/pc
Quantity

Fuse 14x65 with bolted contats 1500VDC gPV UL2579 30A

Reference 5024228.30.0 - Manufacturer SIBA
Class gPV
Rated current In (A) 30
Applicable standards IEC, UL
Power loss (W) 7
Rated Voltage Un DC (V) 1500
Time costant L/R (ms) 3
Rated breaking capacity I1 DC (kA) 30000
Fuse Dimension (mm) 14x65
Melting I²t value (A²s) 149
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 1350
Weight (gr) 38
Price List €28.26/pc
Quantity

Fuse 10/14x85 1500VDC gPV 10A

Reference 5024328.10.0 - Manufacturer SIBA
Class gPV
Rated current In (A) 10
Applicable standards IEC, UL
Power loss (W) 4
Rated Voltage Un DC (V) 1500
Rated breaking capacity I1 DC (kA) 30000
Fuse Dimension (mm) 10/14x85
Melting I²t value (A²s) 5
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 41
Weight (gr) 27
Price List €742.33/pc
Quantity

Fuse 10/14x85 1500VDC gPV 12A

Reference 5024328.12.0 - Manufacturer SIBA
Class gPV
Rated current In (A) 12
Applicable standards IEC, UL
Power loss (W) 4,2
Rated Voltage Un DC (V) 1500
Rated breaking capacity I1 DC (kA) 30000
Fuse Dimension (mm) 10/14x85
Melting I²t value (A²s) 12
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 100
Weight (gr) 27
Price List €743.10/pc
Quantity

Fuse 10/14x85 1500VDC gPV 16A

Reference 5024328.16.0 - Manufacturer SIBA
Class gPV
Rated current In (A) 16
Applicable standards IEC, UL
Power loss (W) 4,7
Rated Voltage Un DC (V) 1500
Rated breaking capacity I1 DC (kA) 30000
Fuse Dimension (mm) 10/14x85
Melting I²t value (A²s) 26
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 210
Weight (gr) 28
Price List €41.95/pc
Quantity

Fuse 10/14x85 1500VDC gPV 20A

Reference 5024328.20.0 - Manufacturer SIBA
Class gPV
Rated current In (A) 20
Applicable standards IEC, UL
Power loss (W) 4
Rated Voltage Un DC (V) 1500
Rated breaking capacity I1 DC (kA) 30000
Fuse Dimension (mm) 10/14x85
Melting I²t value (A²s) 66
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 540
Weight (gr) 27
Price List €43.96/pc
Quantity

Fuse 10/14x85 1500VDC gPV 25A

Reference 5024328.25.0 - Manufacturer SIBA
Class gPV
Rated current In (A) 25
Applicable standards IEC, UL
Power loss (W) 6
Rated Voltage Un DC (V) 1500
Rated breaking capacity I1 DC (kA) 30000
Fuse Dimension (mm) 10/14x85
Melting I²t value (A²s) 90
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 730
Weight (gr) 27
Price List €45.34/pc
Quantity

Fuse 10/14x85 1500VDC gPV 30A

Reference 5024328.30.0 - Manufacturer SIBA
Class gPV
Rated current In (A) 30
Applicable standards IEC, UL
Power loss (W) 7
Rated Voltage Un DC (V) 1500
Rated breaking capacity I1 DC (kA) 30000
Fuse Dimension (mm) 10/14x85
Melting I²t value (A²s) 149
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 1350
Weight (gr) 28
Price List €47.04/pc
Quantity

Fuse 14x65 gFP 1500VDC 1A

Reference 5024406.1.0 - Manufacturer SIBA
Class gFP
Rated current In (A) 1
Rated Voltage Un DC (V) 1500
Time costant L/R (ms) 2
Rated breaking capacity I1 DC (kA) 10000
Fuse Dimension (mm) 14x65
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 1500
Price List €135.18/pc
Quantity

Fuse 10x38 1200VDC gR 1A

Reference 5025506.1.0 - Manufacturer SIBA
Class gR
Rated current In (A) 1
Applicable standards UL
Power loss (W) 3,5
Rated Voltage Un DC (V) 1200
Fuse Dimension (mm) 10x38
Melting I²t value (A²s) 0,32
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 1200
Rated breaking capacity I1 AC (kA) 30000
Weight (gr) 10
Price List €53.87/pc
Quantity

Fuse 10x38 1200VDC gR with pin 1A

Reference 5025606.1.0 - Manufacturer SIBA
Class gR
Rated current In (A) 1
Applicable standards UL
Power loss (W) 3,5
Rated Voltage Un DC (V) 1200
Fuse Dimension (mm) 10x38
Melting I²t value (A²s) 0,32
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 1200
Rated breaking capacity I1 AC (kA) 30000
Weight (gr) 12
Price List €69.98/pc
Quantity

Fuse 22x65 900V gRL (gS) IEC 1000V gR UL 100A

Reference 5026134.100.0 - Manufacturer SIBA
Class gRL, gS
Rated current In (A) 100
Rated Voltage Un AC (V) 1000
Applicable standards IEC, UL
Power loss (W) 11,4
Fuse Dimension (mm) 22x65
Melting I²t value (A²s) 4610
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 1000
Total clearing I²t @Un AC (A²s) 48500
Rated breaking capacity I1 AC (kA) 100000
Price List €52.38/pc
Quantity

Fuse 22x65 900V gRL (gS) IEC 1000V gR UL 32A

Reference 5026134.32.0 - Manufacturer SIBA
Class gRL, gS
Rated current In (A) 32
Rated Voltage Un AC (V) 1000
Applicable standards IEC, UL
Power loss (W) 4,8
Fuse Dimension (mm) 22x65
Melting I²t value (A²s) 250
Fuse Connection/Terminal type Cylindrical
Total clearing I²t @Un AC (A²s) 3800
Rated breaking capacity I1 AC (kA) 100000
Price List €31.43/pc
Quantity

Fuse 22x65 900V gRL (gS) IEC 1000V gR UL 50A

Reference 5026134.50.0 - Manufacturer SIBA
Class gRL, gS
Rated current In (A) 50
Rated Voltage Un AC (V) 1000
Applicable standards IEC, UL
Power loss (W) 6,5
Fuse Dimension (mm) 22x65
Melting I²t value (A²s) 900
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 1000
Total clearing I²t @Un AC (A²s) 13500
Rated breaking capacity I1 AC (kA) 100000
Price List €42.87/pc
Quantity
Filter by
Manufacturer
Series name
Class
Rated Voltage Un AC (V)
Rated Voltage Un DC (V)
Rated insultaion voltage AC (V)
Rated insulated voltage DC (V)
Applicable standards
Product added to compare.
Product added to wishlist