All Products

C300 - Fuse 660VAC aR M12 1250A

Reference 613.574.19.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 1250
Rated Voltage Un AC (V) 690
Dimension SQB3
Applicable standards IEC
Power loss (W) 153
Series name C300
Fuse Dimension (mm) 76x50
Fixing dimensions M12
Melting I²t value (A²s) 275000
Fuse Connection/Terminal type Screw fixing
Total clearing I²t @Un AC (A²s) 1650000
Rated breaking capacity I1 AC (kA) 200
Product available on request Ask for more information

NR2A-Fuse 000/80 aR 500VAC with ind. w/o lug 400A

Reference 613.917.51.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 400
Rated Voltage Un AC (V) 500
Dimension 000
Applicable standards IEC
Power loss (W) 93.5
Time costant L/R (ms) 2
Series name NR2A
Melting I²t value (A²s) 33600
Fuse Connection/Terminal type Screw fixing
Fixing connection centres (mm) 80
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 145000
Rated breaking capacity I1 AC (kA) 200000
Price List €31.93/pc
Quantity

DC22 - Fuse 1000VDC aBat 22x65mm 32A

Reference 615.757.72.0.0 - Manufacturer FAULTRAP
Class aBat
Rated current In (A) 32
Applicable standards IEC
Power loss (W) 6,9
Rated Voltage Un DC (V) 1000
Time costant L/R (ms) 1-3
Series name DC22
Rated breaking capacity I1 DC (kA) 100
Fuse Dimension (mm) 22x65
Melting I²t value (A²s) 155
Fuse Connection/Terminal type Cylindrical
Total clearing I²t @Un DC (A²s) 700
Product available on request Ask for more information

DC22 - Fuse 1000VDC aBat 22x65mm 80A

Reference 616.545.00.0.0 - Manufacturer FAULTRAP
Class aBat
Rated current In (A) 80
Applicable standards IEC
Power loss (W) 16,3
Rated Voltage Un DC (V) 1000
Time costant L/R (ms) 1-3
Series name DC22
Rated breaking capacity I1 DC (kA) 100
Fuse Dimension (mm) 22x65
Melting I²t value (A²s) 1350
Fuse Connection/Terminal type Cylindrical
Total clearing I²t @Un DC (A²s) 5950
Product available on request Ask for more information

A145 - Fuse 14x51 500VAC aR 63A

Reference 616.546.40.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 63
Rated Voltage Un AC (V) 690
Applicable standards IEC
Power loss (W) 16
Series name A145
Fuse Dimension (mm) 14x51
Melting I²t value (A²s) 408
Fuse Connection/Terminal type Cylindrical
Total clearing I²t @Un AC (A²s) 2930
Rated breaking capacity I1 AC (kA) 200
Product available on request Ask for more information

69E1 - Fuse BS 17,2x63,5 aR 690V 110A

Reference 616.958.39.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 110
Rated Voltage Un AC (V) 690
Applicable standards IEC
Power loss (W) 30
Rated Voltage Un DC (V) 500
Series name 69E1
Rated breaking capacity I1 DC (kA) 50
Fuse Dimension (mm) 17x77
Melting I²t value (A²s) 1106
Fuse Connection/Terminal type Screw fixing
Fixing connection centres (mm) 63.5
Total clearing I²t @Un AC (A²s) 4506
Rated breaking capacity I1 AC (kA) 100
Price List €6.64/pc
Quantity

NR2B - Fuse DIN00 80mm aR 700VDC/690VAC with ind. lug 160A

Reference 617.386.84.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 160
Rated Voltage Un AC (V) 690
Dimension 000
Applicable standards IEC, UL
Power loss (W) 37.5
Rated Voltage Un DC (V) 700
Time costant L/R (ms) 2
Series name NR2B
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 3020
Fuse Connection/Terminal type Screw fixing
Fixing connection centres (mm) 80
Voltage of total clearing I2t test 700
Total clearing I²t @Un AC (A²s) 11100
Rated breaking capacity I1 AC (kA) 200000
Price List €59.88/pc
Quantity
Filter by
Manufacturer
Series name
Class
Rated Voltage Un AC (V)
Rated Voltage Un DC (V)
Rated insultaion voltage AC (V)
Rated insulated voltage DC (V)
Applicable standards
Product added to compare.