List of products by manufacturer FAULTRAP

B400 - Fuse 1000V DC aBat DC 2xM12 1600A

Reference 916.702.70.0.0 - Manufacturer FAULTRAP
Class aBat
Rated current In (A) 1600
Applicable standards IEC
Power loss (W) 280
Rated Voltage Un DC (V) 1000
Time costant L/R (ms) 2
Series name B400
Rated breaking capacity I1 DC (kA) 100000
Fuse Dimension (mm) 103x106,5
Fixing dimensions M12
Melting I²t value (A²s) 955600
Fuse Connection/Terminal type Screw fixing
Product available on request Ask for more information

V108 - Fuse 10x85 1500VDC gPV In-line 10A

Reference 919.302.40.0.0 - Manufacturer FAULTRAP
Class gPV
Rated current In (A) 10
Applicable standards IEC, UL
Power loss (W) 2,99
Rated Voltage Un DC (V) 1500
Series name V108
Rated breaking capacity I1 DC (kA) 20000
Fuse Dimension (mm) 10x85
Melting I²t value (A²s) 12,7
Fuse Connection/Terminal type Cylindrical In-line
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 102
Product available on request Ask for more information

NB1E - Fuse holder polyester NH3 690V DIN/Screw 1P

Reference 932.138.49.0.0 - Manufacturer FAULTRAP
Rated current In (A) 630
Rated Voltage Un AC (V) 690
Dimension NH3
Applicable standards IEC
Series name NB1E
Fuse Connection/Terminal type NH knife
Number of poles 1
Price List €21.98/pc
Quantity

G276 - Fuse 500V AC gG /550V gR 27x60 160A

Reference 934.168.97.0.0 - Manufacturer FAULTRAP
Class gG
Rated current In (A) 160
Rated Voltage Un AC (V) 500
Applicable standards IEC
Power loss (W) 12
Series name G276
Fuse Dimension (mm) 27x60
Melting I²t value (A²s) 74650
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 265000
Rated breaking capacity I1 AC (kA) 100000
Product available on request Ask for more information

BPF1 - Fuse 1500VDC aBat d:50mm M8 400A

Reference 939.180.20.0.0 - Manufacturer FAULTRAP
Class aBat
Rated current In (A) 400
Applicable standards IEC
Power loss (W) 70,5
Rated Voltage Un DC (V) 1500
Time costant L/R (ms) 3
Series name BPF1
Rated breaking capacity I1 DC (kA) 100000
Fuse Dimension (mm) 50x168
Melting I²t value (A²s) 73750
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 258150
Product available on request Ask for more information

C100 - Fuse 690V aR size 1 M8 250A

Reference 952.201.47.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 250
Rated Voltage Un AC (V) 690
Dimension SQB2
Applicable standards IEC
Power loss (W) 38
Fixing dimensions M8
Melting I²t value (A²s) 4100
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 28000
Rated breaking capacity I1 AC (kA) 100000
Product available on request Ask for more information
Product added to compare.
Product added to wishlist