List of products by manufacturer FAULTRAP

B200 - Fuse 38x73mm 1000VDC Axial aBat 80A

Reference 190.739.88.0.0 - Manufacturer FAULTRAP
Class aBat
Rated current In (A) 80
Applicable standards IEC
Power loss (W) 14
Rated Voltage Un DC (V) 1000
Time costant L/R (ms) 2
Series name B200
Rated breaking capacity I1 DC (kA) 50000
Fuse Dimension (mm) 38x73
Melting I²t value (A²s) 1300
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 1000
Total clearing I²t @Un AC (A²s) 5000
Product available on request Ask for more information

B500 - Fuse 1500VDC aBat 2xM12 with micro adapter 1500A

Reference 194.777.19.0.0 - Manufacturer FAULTRAP
Class aBat
Rated current In (A) 1500
Applicable standards IEC
Power loss (W) 350
Rated Voltage Un DC (V) 1500
Time costant L/R (ms) 3
Series name B500
Rated breaking capacity I1 DC (kA) 250000
Fuse Dimension (mm) 103x144
Fixing dimensions M12
Melting I²t value (A²s) 1156000
Minimum breaking current (A) 17000
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 6270000
Product available on request Ask for more information

EV65.1000 - Fuse 1000VDC 22x65 cylindrical 75A

Reference 938.403.22.0.0 - Manufacturer FAULTRAP
Class EV full
Rated current In (A) 75
Applicable standards UL
Power loss (W) 13.5
Rated Voltage Un DC (V) 1000
Time costant L/R (ms) 2,5
Series name EV65.1000
Rated breaking capacity I1 DC (kA) 25000
Fuse Dimension (mm) 22x65
Melting I²t value (A²s) 2480
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 1000
Total clearing I²t @Un AC (A²s) 7300
Product available on request Ask for more information

EV65.1500 - Fuse 1500VDC 22x65 cylindrical 75A

Reference 942.825.21.0.0 - Manufacturer FAULTRAP
Class EV full
Rated current In (A) 75
Applicable standards UL
Power loss (W) 13.5
Rated Voltage Un DC (V) 1500
Time costant L/R (ms) 2,5
Series name EV65.1500
Rated breaking capacity I1 DC (kA) 25000
Fuse Dimension (mm) 22x65
Melting I²t value (A²s) 2480
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 12500
Product available on request Ask for more information

EV65.1000 - Fuse 1000VDC 22x65 cylindrical 50A

Reference 968.836.79.0.0 - Manufacturer FAULTRAP
Class EV full
Rated current In (A) 50
Applicable standards UL
Power loss (W) 11
Rated Voltage Un DC (V) 1000
Time costant L/R (ms) 2,5
Series name EV65.1000
Rated breaking capacity I1 DC (kA) 25000
Fuse Dimension (mm) 22x65
Melting I²t value (A²s) 685
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 1000
Total clearing I²t @Un AC (A²s) 2800
Product available on request Ask for more information

E103 - Fuse 10x38 700VDC aBAT 40A

Reference 971.827.03.0.0 - Manufacturer FAULTRAP
Class aBat
Rated current In (A) 40
Applicable standards IEC
Power loss (W) 4,6
Rated Voltage Un DC (V) 700
Series name E103
Rated breaking capacity I1 DC (kA) 20000
Fuse Dimension (mm) 10x38
Fuse Connection/Terminal type Cylindrical
Price List €4.60/pc
Quantity

E103 - Fuse 10x38 700VDC aBAT 35A

Reference 977.799.61.0.0 - Manufacturer FAULTRAP
Class aBat
Rated current In (A) 35
Applicable standards IEC
Power loss (W) 4,4
Rated Voltage Un DC (V) 700
Series name E103
Rated breaking capacity I1 DC (kA) 20000
Fuse Dimension (mm) 10x38
Fuse Connection/Terminal type Cylindrical
Product available on request Ask for more information

M050 - Fuse 500V DC 10x38 15A

Reference 548.582.23.0.0 - Manufacturer FAULTRAP
Class EV full
Rated current In (A) 15
Power loss (W) 5,2
Rated Voltage Un DC (V) 500
Series name M050
Fuse Dimension (mm) 10x38
Fuse Connection/Terminal type Cylindrical
Product available on request Ask for more information

L108 - In-Line Rugged 10x85 Fuse + Holder 1500VDC 15A

Reference 587.152.07.0.0 - Manufacturer FAULTRAP
Class gPV
Rated current In (A) 15
Applicable standards IEC
Power loss (W) 3,6
Rated Voltage Un DC (V) 1500
Series name L108
Rated breaking capacity I1 DC (kA) 20000
Fuse Dimension (mm) 10x85
Melting I²t value (A²s) 29,2
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 329
Product available on request Ask for more information

EV65.1000 - Fuse 1000VDC 22x65 cylindrical 80A

Reference 587.419.17.0.0 - Manufacturer FAULTRAP
Class EV full
Rated current In (A) 80
Applicable standards UL
Power loss (W) 14,9
Rated Voltage Un DC (V) 1000
Time costant L/R (ms) 2,5
Series name EV65.1000
Rated breaking capacity I1 DC (kA) 25000
Fuse Dimension (mm) 22x65
Melting I²t value (A²s) 3000
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 1000
Total clearing I²t @Un AC (A²s) 8750
Product available on request Ask for more information
Product added to compare.
Product added to wishlist