List of products by manufacturer SIBA

Fuse 17,5kV 53x367 back-up with striker 2,5A 80N

Reference 3017613.2,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 2,5
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 12
Resistance (ohm) 1,4
Fuse Dimension (mm) 53x367
Melting I²t value (A²s) 7,2
Minimum breaking current (A) 20
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 24
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 1980
Product available on request Ask for more information

Fuse 17,5kV 53x367 back-up with striker 2A 80N

Reference 3017613.2.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 2
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 11
Resistance (ohm) 2,06
Fuse Dimension (mm) 53x367
Melting I²t value (A²s) 3,2
Minimum breaking current (A) 16
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 9,8
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 1980
Price List €70.09/pc
Quantity

Fuse 17,5kV 53x367 back-up with striker 20A 80N

Reference 3017613.20.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 20
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 35
Resistance (ohm) 0,062
Fuse Dimension (mm) 53x367
Melting I²t value (A²s) 545
Minimum breaking current (A) 70
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 4400
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 1980
Price List €80.45/pc
Quantity

Fuse 17,5kV 53x367 back-up with striker 25A 80N

Reference 3017613.25.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 25
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 42
Resistance (ohm) 0,048
Fuse Dimension (mm) 53x367
Melting I²t value (A²s) 920
Minimum breaking current (A) 90
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 5400
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 1990
Price List €82.73/pc
Quantity

Fuse 17,5kV 53x367 back-up with striker 3,15A 80N

Reference 3017613.3,15.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 3,15
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 13
Resistance (ohm) 0,92
Fuse Dimension (mm) 53x367
Melting I²t value (A²s) 17
Minimum breaking current (A) 24
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 48
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 1980
Price List €61.82/pc
Quantity

Fuse 17,5kV 53x367 back-up with striker 4A 80N

Reference 3017613.4.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 4
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 16
Resistance (ohm) 0,69
Fuse Dimension (mm) 53x367
Melting I²t value (A²s) 31
Minimum breaking current (A) 32
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 90
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 1980
Price List €68.58/pc
Quantity

Fuse 17,5kV 53x367 back-up with striker 5A 80N

Reference 3017613.5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 5
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 11
Resistance (ohm) 0,314
Fuse Dimension (mm) 53x367
Melting I²t value (A²s) 40
Minimum breaking current (A) 40
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 125
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 1980
Price List €46.00/pc
Quantity

Fuse 17,5kV 67x367 back-up with striker 31,5A 80N

Reference 3017713.31,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 31,5
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 54
Resistance (ohm) 0,039
Fuse Dimension (mm) 67x367
Melting I²t value (A²s) 1400
Minimum breaking current (A) 110
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 9800
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 3090
Price List €91.35/pc
Quantity

Fuse 17,5kV 53x367 back-up with striker 6,3A 80N

Reference 3017613.6,3.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 6,3
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 22
Resistance (ohm) 0,402
Fuse Dimension (mm) 53x367
Melting I²t value (A²s) 27
Minimum breaking current (A) 22
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 520
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 1980
Price List €70.09/pc
Quantity

Fuse 17,5kV 85x367 back-up with striker 125ARC105 80N

Reference 3017813.125.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 125
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 116
Resistance (ohm) 0,0067
Fuse Dimension (mm) 85x367
Melting I²t value (A²s) 47400
Minimum breaking current (A) 390
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 335000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 4790
Price List €228.83/pc
Quantity

Fuse 17,5kV 85x367 back-up with striker 100ARC90 80N

Reference 3017813.100.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 100
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 109
Resistance (ohm) 0,0087
Fuse Dimension (mm) 85x367
Melting I²t value (A²s) 28000
Minimum breaking current (A) 320
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 199000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 4790
Price List €186.98/pc
Quantity

Fuse 17,5kV 67x367 back-up with striker 50A 80N

Reference 3017713.50.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 50
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 75
Resistance (ohm) 0,021
Fuse Dimension (mm) 67x367
Melting I²t value (A²s) 4700
Minimum breaking current (A) 170
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 33000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 3090
Price List €126.20/pc
Quantity
Product added to compare.
Product added to wishlist