List of products by manufacturer SIBA

Fuse railway application 39,6x254 gR 4000VDC 3,15A

Reference 9010010.3,15.0 - Manufacturer SIBA
Class gR
Rated current In (A) 3,15
Applicable standards IEC
Power loss (W) 13
Rated Voltage Un DC (V) 3600
Time costant L/R (ms) 15
Rated breaking capacity I1 DC (kA) 3200
Fuse Dimension (mm) 39,6x254
Melting I²t value (A²s) 4
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 4000
Total clearing I²t @Un AC (A²s) 8
Weight (gr) 780
Price List €301.99/pc
Quantity

Fuse railway application 39,6x254 gR 4000VDC 3,15A (TR357/36

Reference 9010010.3,15TR.0 - Manufacturer SIBA
Class gR
Rated current In (A) 3,15
Applicable standards IEC
Power loss (W) 13
Rated Voltage Un DC (V) 3600
Time costant L/R (ms) 15
Rated breaking capacity I1 DC (kA) 3200
Fuse Dimension (mm) 39,6x254
Melting I²t value (A²s) 4
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 4000
Total clearing I²t @Un AC (A²s) 8
Weight (gr) 780
Price List €105.16/pc
Quantity

Fuse railway application 39,6x254 gR 4000VDC 3,9A

Reference 9010010.3,9.0 - Manufacturer SIBA
Class gR
Rated current In (A) 3,9
Applicable standards IEC
Power loss (W) 24
Rated Voltage Un DC (V) 3600
Time costant L/R (ms) 15
Rated breaking capacity I1 DC (kA) 3200
Fuse Dimension (mm) 39,6x254
Melting I²t value (A²s) 8
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 4000
Total clearing I²t @Un AC (A²s) 13
Weight (gr) 760
Price List €329.30/pc
Quantity

Fuse railway application 39,6x454 gR 4000VDC 3,15A (TR357/37

Reference 9010010.3,9TR.0 - Manufacturer SIBA
Class gR
Rated current In (A) 3,9
Applicable standards IEC
Power loss (W) 24
Rated Voltage Un DC (V) 3600
Time costant L/R (ms) 15
Rated breaking capacity I1 DC (kA) 3200
Fuse Dimension (mm) 39,6x254
Melting I²t value (A²s) 8
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 4000
Total clearing I²t @Un AC (A²s) 13
Weight (gr) 760
Price List €215.83/pc
Quantity

Fuse railway application 39,6x454 gR 4000VDC 31,5A (TR357/36

Reference 9010010.31,5TR.0 - Manufacturer SIBA
Class gR
Rated current In (A) 31,5
Applicable standards IEC
Power loss (W) 40
Rated Voltage Un DC (V) 3600
Time costant L/R (ms) 15
Rated breaking capacity I1 DC (kA) 3200
Fuse Dimension (mm) 39,6x254
Melting I²t value (A²s) 410
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 4000
Total clearing I²t @Un AC (A²s) 1300
Weight (gr) 800
Price List €120.25/pc
Quantity

Fuse railway application 39,6x254 gR 4000VDC 5A

Reference 9010010.5.0 - Manufacturer SIBA
Class gR
Rated current In (A) 5
Applicable standards IEC
Power loss (W) 18
Rated Voltage Un DC (V) 3600
Time costant L/R (ms) 15
Rated breaking capacity I1 DC (kA) 3200
Fuse Dimension (mm) 39,6x254
Melting I²t value (A²s) 15
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 4000
Total clearing I²t @Un AC (A²s) 21
Weight (gr) 800
Price List €302.79/pc
Quantity

Fuse railway application 39,6x254 gR 4000VDC 5A (TR357/368)

Reference 9010010.5TR.0 - Manufacturer SIBA
Class gR
Rated current In (A) 5
Applicable standards IEC
Power loss (W) 18
Rated Voltage Un DC (V) 3600
Time costant L/R (ms) 15
Rated breaking capacity I1 DC (kA) 3200
Fuse Dimension (mm) 39,6x254
Melting I²t value (A²s) 15
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 4000
Total clearing I²t @Un AC (A²s) 21
Weight (gr) 800
Price List €105.33/pc
Quantity

Fuse railway application 39,6x254 gR 4000VDC 6,3A

Reference 9010010.6,3.0 - Manufacturer SIBA
Class gR
Rated current In (A) 6,3
Applicable standards IEC
Power loss (W) 22
Rated Voltage Un DC (V) 3600
Time costant L/R (ms) 15
Rated breaking capacity I1 DC (kA) 3200
Fuse Dimension (mm) 39,6x254
Melting I²t value (A²s) 24
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 4000
Total clearing I²t @Un AC (A²s) 41
Weight (gr) 800
Price List €302.79/pc
Quantity

Fuse railway application 39,6x254 gR 4000VDC 6,3A (TR357/369

Reference 9010010.6,3TR.0 - Manufacturer SIBA
Class gR
Rated current In (A) 6,3
Applicable standards IEC
Power loss (W) 22
Rated Voltage Un DC (V) 3600
Time costant L/R (ms) 15
Rated breaking capacity I1 DC (kA) 3200
Fuse Dimension (mm) 39,6x254
Melting I²t value (A²s) 24
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 4000
Total clearing I²t @Un AC (A²s) 41
Weight (gr) 800
Product available on request Ask for more information

Fuse railway application 39,6x254 gR 4000VDC 8A

Reference 9010010.8.0 - Manufacturer SIBA
Class gR
Rated current In (A) 8
Applicable standards IEC
Power loss (W) 21
Rated Voltage Un DC (V) 3600
Time costant L/R (ms) 15
Rated breaking capacity I1 DC (kA) 3200
Fuse Dimension (mm) 39,6x254
Melting I²t value (A²s) 27
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 4000
Total clearing I²t @Un AC (A²s) 110
Weight (gr) 780
Price List €303.36/pc
Quantity

Fuse railway application 39,6x254 gR 4000VDC 8A (TR357/370)

Reference 9010010.8TR.0 - Manufacturer SIBA
Class gR
Rated current In (A) 8
Applicable standards IEC
Power loss (W) 21
Rated Voltage Un DC (V) 3600
Time costant L/R (ms) 15
Rated breaking capacity I1 DC (kA) 3200
Fuse Dimension (mm) 39,6x254
Melting I²t value (A²s) 27
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 4000
Total clearing I²t @Un AC (A²s) 110
Weight (gr) 780
Price List €105.45/pc
Quantity

Fuse railway application 40x254 3000V DC without pin 12,5A

Reference 9010110.12,5.0 - Manufacturer SIBA
Class gR
Rated current In (A) 12,5
Applicable standards IEC
Power loss (W) 40
Rated Voltage Un DC (V) 3600
Time costant L/R (ms) 15
Rated breaking capacity I1 DC (kA) 3200
Fuse Dimension (mm) 39,6x254
Melting I²t value (A²s) 68
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 4000
Total clearing I²t @Un AC (A²s) 220
Weight (gr) 780
Price List €141.13/pc
Quantity

Fuse 794/667 for resistive divider RFI 2A

Reference 9011010.2.0 - Manufacturer SIBA
Rated current In (A) 2
Rated Voltage Un DC (V) 3000
Fuse Connection/Terminal type Cylindrical
Weight (gr) 420
Price List €211.88/pc
Quantity

Fuse SQB2 gR 3600V/4000VDC 160A

Reference 9020020.160.0 - Manufacturer SIBA
Class gR
Rated current In (A) 160
Dimension SQB2
Applicable standards IEC
Power loss (W) 183
Rated Voltage Un DC (V) 4000
Time costant L/R (ms) 15
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 6650
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 4000
Total clearing I²t @Un AC (A²s) 55200
Weight (gr) 3880
Price List €518.11/pc
Quantity

Fuse SQB2 gR 3600V/4000VDC lateral switch adapter 160A

Reference 9020021.160.0 - Manufacturer SIBA
Class gR
Rated current In (A) 160
Dimension SQB2
Applicable standards IEC
Power loss (W) 143
Rated Voltage Un DC (V) 4000
Time costant L/R (ms) 15
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 4600
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 4000
Total clearing I²t @Un AC (A²s) 38200
Weight (gr) 3700
Price List €2,231.84/pc
Quantity

Fuse SQB2 gR 3600V/4000VDC lateral switch adapter 200A

Reference 9020021.200.0 - Manufacturer SIBA
Class gR
Rated current In (A) 200
Dimension SQB2
Applicable standards IEC
Power loss (W) 183
Rated Voltage Un DC (V) 4000
Time costant L/R (ms) 15
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 6650
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 4000
Total clearing I²t @Un AC (A²s) 55200
Weight (gr) 3700
Price List €2,445.75/pc
Quantity

Fuse SQB2 gR 3600V/4000VDC lateral switch adap (TR696/790)

Reference 9020021.200TR.0 - Manufacturer SIBA
Class gR
Rated current In (A) 200
Dimension SQB2
Applicable standards IEC
Power loss (W) 183
Rated Voltage Un DC (V) 4000
Time costant L/R (ms) 15
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 6650
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 4000
Total clearing I²t @Un AC (A²s) 55200
Weight (gr) 3700
Price List €618.89/pc
Quantity

Fuse SQB2 aR 3600V/4200VDC without indicator 100A

Reference 9020025.100.0 - Manufacturer SIBA
Class aR
Rated current In (A) 100
Dimension SQB2
Applicable standards IEC
Power loss (W) 75
Rated Voltage Un DC (V) 3600
Time costant L/R (ms) 15
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 2300
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 4200
Total clearing I²t @Un AC (A²s) 19000
Weight (gr) 3920
Price List €1,121.19/pc
Quantity

Fuse SQB2 aR 3600V/4200VDC without indicator 125A

Reference 9020025.125.0 - Manufacturer SIBA
Class aR
Rated current In (A) 125
Dimension SQB2
Applicable standards IEC
Power loss (W) 90
Rated Voltage Un DC (V) 3600
Time costant L/R (ms) 15
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 4000
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 4200
Total clearing I²t @Un AC (A²s) 33500
Weight (gr) 3920
Price List €4,333.43/pc
Quantity

Fuse SQB2 aR 3600V/4200VDC without indicator 160A

Reference 9020025.160.0 - Manufacturer SIBA
Class aR
Rated current In (A) 160
Dimension SQB2
Applicable standards IEC
Power loss (W) 120
Rated Voltage Un DC (V) 3600
Time costant L/R (ms) 15
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 6600
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 4200
Total clearing I²t @Un AC (A²s) 55300
Weight (gr) 3920
Price List €1,385.37/pc
Quantity

Fuse SQB2 aR 3600V/4200VDC without indicator 160A 357/417

Reference 9020025.160TR.0 - Manufacturer SIBA
Class aR
Rated current In (A) 160
Dimension SQB2
Applicable standards IEC
Power loss (W) 120
Rated Voltage Un DC (V) 3600
Time costant L/R (ms) 15
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 6600
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 4200
Total clearing I²t @Un AC (A²s) 55300
Weight (gr) 3920
Price List €481.27/pc
Quantity

Fuse SQB2 gR 1800/2000VDC without indicator 160A

Reference 9020120.160.0 - Manufacturer SIBA
Class gR
Rated current In (A) 160
Dimension SQB2
Applicable standards IEC
Power loss (W) 91
Rated Voltage Un DC (V) 1800
Time costant L/R (ms) 15
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 4000
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 2000
Total clearing I²t @Un AC (A²s) 33500
Weight (gr) 2367
Price List €410.75/pc
Quantity

Fuse SQB2 aR 3600V/4200VDC with indicator 355A

Reference 9020026.355.0 - Manufacturer SIBA
Class aR
Rated current In (A) 355
Dimension SQB2
Rated Voltage Un DC (V) 3600
Time costant L/R (ms) 15
Rated breaking capacity I1 DC (kA) 30000
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 4200
Weight (gr) 3860
Price List €757.48/pc
Quantity

Fuse SQB2 aR 3600V/4200VDC with indicator 315A

Reference 9020026.315.0 - Manufacturer SIBA
Class aR
Rated current In (A) 315
Dimension SQB2
Applicable standards IEC
Power loss (W) 220
Rated Voltage Un DC (V) 3600
Time costant L/R (ms) 15
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 33000
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 4200
Total clearing I²t @Un AC (A²s) 273000
Weight (gr) 3920
Price List €1,621.65/pc
Quantity
Product added to compare.
Product added to wishlist