List of products by manufacturer SIBA

Fuse 12kV 53x442 back-up with striker 2A 80N

Reference 3010113.2.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 2
Rated Voltage Un AC (V) 6000
Applicable standards IEC
Power loss (W) 8.2
Resistance (ohm) 1,57
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 3,2
Minimum breaking current (A) 16
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 5220
Total clearing I²t @Un AC (A²s) 9,8
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2300
Price List €207.50/pc
Quantity

Fuse 12kV 53x442 back-up with striker 16A 80N

Reference 3010113.16.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 16
Rated Voltage Un AC (V) 6000
Applicable standards IEC
Power loss (W) 29
Resistance (ohm) 0,092
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 140
Minimum breaking current (A) 56
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 5220
Total clearing I²t @Un AC (A²s) 2360
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2300
Price List €247.76/pc
Quantity

Fuse 12kV 53x442 back-up with striker 10A 80N

Reference 3010113.10.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 10
Rated Voltage Un AC (V) 6000
Applicable standards IEC
Power loss (W) 25
Resistance (ohm) 0,189
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 68
Minimum breaking current (A) 34
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 5220
Total clearing I²t @Un AC (A²s) 1260
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2300
Price List €246.49/pc
Quantity

Fuse 7,2kV 87x292 back-up striker no temp.lim355ARC225

Reference 3010014.355LM.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 355
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Power loss (W) 76
Resistance (ohm) 0,0011
Fuse Dimension (mm) 85x292
Melting I²t value (A²s) 794000
Minimum breaking current (A) 1370
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 6264
Total clearing I²t @Un AC (A²s) 3700000
Rated breaking capacity I1 AC (kA) 80000
Weight (gr) 3870
Price List €751.98/pc
Quantity

Fuse 7,2kV 87x292 back-up striker no temp.lim315ARC200

Reference 3010014.315LM.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 315
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Power loss (W) 76
Resistance (ohm) 0,0013
Fuse Dimension (mm) 85x292
Melting I²t value (A²s) 551000
Minimum breaking current (A) 1250
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 6264
Total clearing I²t @Un AC (A²s) 2200000
Rated breaking capacity I1 AC (kA) 80000
Price List €690.60/pc
Quantity

Fuse 7,2kV 85x292 back-up striker no temp.lim250ARC180

Reference 3010014.250.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 250
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Power loss (W) 65
Resistance (ohm) 0,0015
Fuse Dimension (mm) 85x292
Melting I²t value (A²s) 405000
Minimum breaking current (A) 1000
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 6264
Total clearing I²t @Un AC (A²s) 1600000
Rated breaking capacity I1 AC (kA) 80000
Weight (gr) 3870
Price List €382.60/pc
Quantity

Fuse 7,2kV 85x292 back-up striker no temp.lim200ARC160

Reference 3010014.200.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 200
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Power loss (W) 80
Resistance (ohm) 0,0018
Fuse Dimension (mm) 85x292
Melting I²t value (A²s) 266000
Minimum breaking current (A) 800
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 6264
Total clearing I²t @Un AC (A²s) 1150000
Rated breaking capacity I1 AC (kA) 80000
Weight (gr) 3870
Price List €644.34/pc
Quantity

Fuse 7,2kV 85x292 back-up with striker 160ARC140 80N

Reference 3010013.160.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 160
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Power loss (W) 80
Resistance (ohm) 0,0024
Fuse Dimension (mm) 85x292
Melting I²t value (A²s) 78500
Minimum breaking current (A) 600
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 6264
Total clearing I²t @Un AC (A²s) 681600
Rated breaking capacity I1 AC (kA) 80000
Weight (gr) 3900
Price List €581.48/pc
Quantity

Fuse 7,2kV 53x292 back-up with striker 20A 80N

Reference 3009813.20.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 20
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Power loss (W) 13
Resistance (ohm) 0,028
Fuse Dimension (mm) 53x292
Melting I²t value (A²s) 550
Minimum breaking current (A) 70
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 6264
Total clearing I²t @Un AC (A²s) 4800
Rated breaking capacity I1 AC (kA) 80000
Weight (gr) 1580
Price List €236.41/pc
Quantity

Fuse 7,2kV 53x292 back-up with striker 16A 80N

Reference 3009813.16.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 16
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Power loss (W) 19
Resistance (ohm) 0,055
Fuse Dimension (mm) 53x292
Melting I²t value (A²s) 140
Minimum breaking current (A) 56
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 6264
Total clearing I²t @Un AC (A²s) 1250
Rated breaking capacity I1 AC (kA) 80000
Weight (gr) 1700
Price List €600.54/pc
Quantity

Fuse 7,2kV 53x292 TV with striker 2A 80N

Reference 3009813.2.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 2
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Power loss (W) 5
Resistance (ohm) 0,935
Fuse Dimension (mm) 53x292
Melting I²t value (A²s) 3,2
Minimum breaking current (A) 16
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 6264
Total clearing I²t @Un AC (A²s) 12
Rated breaking capacity I1 AC (kA) 80000
Weight (gr) 1600
Price List €113.88/pc
Quantity

Fuse 36kV 85x537 back-up 80A with striker 120N

Reference 3002414.80.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 80
Rated Voltage Un AC (V) 36000
Applicable standards IEC
Power loss (W) 145
Resistance (ohm) 23
Fuse Dimension (mm) 85x537
Melting I²t value (A²s) 17000
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 36000
Total clearing I²t @Un AC (A²s) 171000
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 6730
Price List €1,152.78/pc
Quantity
Product added to compare.
Product added to wishlist