List of products by manufacturer SIBA

Fuse 40,5kV 67x537 back-up with striker 31,5A 80N

Reference 3034113.31,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 31,5
Rated Voltage Un AC (V) 40500
Applicable standards IEC
Power loss (W) 157
Resistance (ohm) 0,098
Fuse Dimension (mm) 537x67
Melting I²t value (A²s) 1400
Minimum breaking current (A) 110
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 35235
Total clearing I²t @Un AC (A²s) 12500
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 4450
Price List €154.43/pc
Quantity

Fuse 40,5kV 67x537 back-up with striker 40A 80N

Reference 3034113.40.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 40
Rated Voltage Un AC (V) 40500
Applicable standards IEC
Power loss (W) 202
Resistance (ohm) 0,073
Fuse Dimension (mm) 537x67
Melting I²t value (A²s) 2500
Minimum breaking current (A) 140
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 35235
Total clearing I²t @Un AC (A²s) 19800
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 4450
Price List €176.40/pc
Quantity

Fuse 40,5kV 85x537 back-up with striker 50ARC45 80N

Reference 3034213.50.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 50
Rated Voltage Un AC (V) 40500
Applicable standards IEC
Power loss (W) 180
Resistance (ohm) 0,053
Fuse Dimension (mm) 85x537
Melting I²t value (A²s) 4700
Minimum breaking current (A) 170
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 35235
Total clearing I²t @Un AC (A²s) 34000
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 6800
Price List €250.21/pc
Quantity

Fuse 40,5kV 85x537 back-up with striker 63ARC50 80N

Reference 3034213.63.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 63
Rated Voltage Un AC (V) 40500
Applicable standards IEC
Power loss (W) 182
Resistance (ohm) 0,039
Fuse Dimension (mm) 85x537
Melting I²t value (A²s) 8700
Minimum breaking current (A) 210
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 35235
Total clearing I²t @Un AC (A²s) 64000
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 6660
Price List €268.88/pc
Quantity

Fuse 40,5kV 537x53 SSK with striker 80A 80N

Reference 3034243.80.0 - Manufacturer SIBA
Class HH SSK
Rated current In (A) 80
Rated Voltage Un AC (V) 25000
Applicable standards IEC
Power loss (W) 205
Resistance (ohm) 23
Fuse Dimension (mm) 85x537
Melting I²t value (A²s) 18400
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 40500
Total clearing I²t @Un AC (A²s) 102000
Rated breaking capacity I1 AC (kA) 300000
Weight (gr) 6760
Price List €316.27/pc
Quantity

Fuse 12kV 53x537 back-up with striker 10A 80N

Reference 3034413.10.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 10
Rated Voltage Un AC (V) 6000
Applicable standards IEC
Power loss (W) 23
Resistance (ohm) 0,189
Fuse Dimension (mm) 53x537
Melting I²t value (A²s) 68
Minimum breaking current (A) 34
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 5220
Total clearing I²t @Un AC (A²s) 1260
Rated breaking capacity I1 AC (kA) 63000
Price List €243.10/pc
Quantity

Fuse 12kV 53x537 back-up with striker 16A 80N

Reference 3034413.16.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 16
Rated Voltage Un AC (V) 6000
Applicable standards IEC
Power loss (W) 29
Resistance (ohm) 0,092
Fuse Dimension (mm) 53x537
Melting I²t value (A²s) 140
Minimum breaking current (A) 56
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 5220
Total clearing I²t @Un AC (A²s) 2360
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2000
Price List €89.22/pc
Quantity

Fuse 12kV 53x537 back-up with striker 20A 80N

Reference 3034413.20.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 20
Rated Voltage Un AC (V) 6000
Applicable standards IEC
Power loss (W) 21
Resistance (ohm) 0,047
Fuse Dimension (mm) 53x537
Melting I²t value (A²s) 545
Minimum breaking current (A) 70
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 5220
Total clearing I²t @Un AC (A²s) 4200
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2700
Price List €244.70/pc
Quantity

Fuse 12kV 53x537 back-up with striker 25A 80N

Reference 3034413.25.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 25
Rated Voltage Un AC (V) 6000
Applicable standards IEC
Power loss (W) 27
Resistance (ohm) 0,036
Fuse Dimension (mm) 53x537
Melting I²t value (A²s) 920
Minimum breaking current (A) 90
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 5220
Total clearing I²t @Un AC (A²s) 7100
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2700
Price List €275.98/pc
Quantity

Fuse 12kV 53x537 back-up with striker 31,5A 80N

Reference 3034413.31,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 31,5
Rated Voltage Un AC (V) 6000
Applicable standards IEC
Power loss (W) 37
Resistance (ohm) 0,029
Fuse Dimension (mm) 53x537
Melting I²t value (A²s) 1400
Minimum breaking current (A) 110
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 5220
Total clearing I²t @Un AC (A²s) 10800
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2700
Price List €123.08/pc
Quantity

Fuse 12kV 53x537 back-up with striker 40A 80N

Reference 3034413.40.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 40
Rated Voltage Un AC (V) 6000
Applicable standards IEC
Power loss (W) 45
Resistance (ohm) 0,022
Fuse Dimension (mm) 53x537
Melting I²t value (A²s) 2500
Minimum breaking current (A) 140
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 5220
Total clearing I²t @Un AC (A²s) 19000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2700
Price List €124.61/pc
Quantity

Fuse 12kV 53x537 back-up with striker 50A 80N

Reference 3034413.50.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 50
Rated Voltage Un AC (V) 6000
Applicable standards IEC
Power loss (W) 54
Resistance (ohm) 0,016
Fuse Dimension (mm) 53x537
Melting I²t value (A²s) 4700
Minimum breaking current (A) 170
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 5220
Total clearing I²t @Un AC (A²s) 36000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2000
Price List €127.77/pc
Quantity

Fuse 12kV 53x537 back-up with striker 6,3A 80N

Reference 3034413.6,3.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 6,3
Rated Voltage Un AC (V) 6000
Applicable standards IEC
Power loss (W) 15
Resistance (ohm) 0,302
Fuse Dimension (mm) 53x537
Melting I²t value (A²s) 27
Minimum breaking current (A) 22
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 5220
Total clearing I²t @Un AC (A²s) 890
Rated breaking capacity I1 AC (kA) 63000
Product available on request Ask for more information

Fuse 12kV 67x537 back-up with striker 63A 80N

Reference 3034513.63.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 63
Rated Voltage Un AC (V) 6000
Applicable standards IEC
Power loss (W) 66
Resistance (ohm) 0,0125
Fuse Dimension (mm) 67x537
Melting I²t value (A²s) 8700
Minimum breaking current (A) 210
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 5220
Total clearing I²t @Un AC (A²s) 67000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 4280
Price List €135.97/pc
Quantity

Fuse 7,2 kV 76x359 1/2 UNC 125A

Reference 3035321.125.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 125
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Power loss (W) 117
Fuse Dimension (mm) 76x359
Melting I²t value (A²s) 47000
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 7200
Total clearing I²t @Un AC (A²s) 351000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 3820
Price List €554.08/pc
Quantity

Fuse 7,2 kV 63,5x254 1/2 UNC 20A

Reference 3035221.20.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 20
Rated Voltage Un AC (V) 15500
Applicable standards IEC
Power loss (W) 21
Fuse Dimension (mm) 63,5x254
Melting I²t value (A²s) 640
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15500
Total clearing I²t @Un AC (A²s) 4300
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2040
Price List €374.82/pc
Quantity

Fuse 7,2 kV 63,5x254 1/2 UNC 25A

Reference 3035221.25.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 25
Rated Voltage Un AC (V) 15500
Applicable standards IEC
Power loss (W) 24
Fuse Dimension (mm) 63,5x254
Melting I²t value (A²s) 1050
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15500
Total clearing I²t @Un AC (A²s) 6700
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2040
Product available on request Ask for more information

Fuse 7,2 kV 63,5x254 1/2 UNC 31,5A

Reference 3035221.31,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 31,5
Rated Voltage Un AC (V) 15500
Applicable standards IEC
Power loss (W) 30
Fuse Dimension (mm) 63,5x254
Melting I²t value (A²s) 1700
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15500
Total clearing I²t @Un AC (A²s) 10800
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2040
Price List €376.29/pc
Quantity

Fuse 7,2 kV 63,5x254 1/2 UNC 40A

Reference 3035221.40.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 40
Rated Voltage Un AC (V) 15500
Applicable standards IEC
Power loss (W) 39
Fuse Dimension (mm) 63,5x254
Melting I²t value (A²s) 2900
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15500
Total clearing I²t @Un AC (A²s) 17100
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2040
Product available on request Ask for more information

Fuse 7,2 kV 63,5x254 1/2 UNC 50A

Reference 3035221.50.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 50
Rated Voltage Un AC (V) 15500
Applicable standards IEC
Power loss (W) 45
Fuse Dimension (mm) 63,5x254
Melting I²t value (A²s) 5700
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15500
Total clearing I²t @Un AC (A²s) 29700
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2040
Product available on request Ask for more information

Fuse 7,2 kV 63,5x254 1/2 UNC 6,3A

Reference 3035221.6,3.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 6,3
Rated Voltage Un AC (V) 15500
Applicable standards IEC
Power loss (W) 16
Fuse Dimension (mm) 63,5x254
Melting I²t value (A²s) 45
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15500
Total clearing I²t @Un AC (A²s) 330
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2040
Product available on request Ask for more information

Fuse 7,2 kV 63,5x254 1/2 UNC 63A

Reference 3035221.63.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 63
Rated Voltage Un AC (V) 15500
Applicable standards IEC
Power loss (W) 55
Fuse Dimension (mm) 63,5x254
Melting I²t value (A²s) 10700
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15500
Total clearing I²t @Un AC (A²s) 59400
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2040
Price List €381.43/pc
Quantity

Fuse 7,2 kV 63,5x254 1/2 UNC 80A

Reference 3035221.80.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 80
Rated Voltage Un AC (V) 15500
Applicable standards IEC
Power loss (W) 63
Fuse Dimension (mm) 63,5x254
Melting I²t value (A²s) 21000
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15500
Total clearing I²t @Un AC (A²s) 126000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2062
Price List €372.51/pc
Quantity

Fuse 15,5kV 63,5x359 1/2 UNC 25A

Reference 3035421.25.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 25
Rated Voltage Un AC (V) 15500
Applicable standards IEC
Power loss (W) 56
Fuse Dimension (mm) 63,5x359
Melting I²t value (A²s) 1050
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15500
Total clearing I²t @Un AC (A²s) 6700
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2000
Price List €430.37/pc
Quantity
Product added to compare.
Product added to wishlist