Home

Fuse Motors DIN-ANSI 7,2kV 53x442 100A

Reference 3010855.3R.0 - Manufacturer SIBA
Class HH Motors
Rated current In (A) 100
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Power loss (W) 106
R-Rating 3
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 9000
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 7200
Total clearing I²t @Un AC (A²s) 41400
Rated breaking capacity I1 AC (kA) 5000
Weight (gr) 5600
Price List €1,485.05/pc
Quantity

Fuse Motors DIN-ANSI 7,2kV 53x442 70A

Reference 3010855.2R.0 - Manufacturer SIBA
Class HH Motors
Rated current In (A) 70
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Power loss (W) 63
R-Rating 2
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 5400
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 7200
Total clearing I²t @Un AC (A²s) 24400
Rated breaking capacity I1 AC (kA) 5000
Weight (gr) 5600
Price List €1,557.12/pc
Quantity

Fuse DIN Motors 7,2kV 53x442 with striker 80A 80N

Reference 3010853.80.0 - Manufacturer SIBA
Class HH Motors
Rated current In (A) 80
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Power loss (W) 72
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 6200
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 7200
Total clearing I²t @Un AC (A²s) 29000
Rated breaking capacity I1 AC (kA) 50000
Weight (gr) 2400
Price List €304.77/pc
Quantity

Fuse DIN Motors 7,2kV 53x442 with striker 63A 80N

Reference 3010853.63.0 - Manufacturer SIBA
Class HH Motors
Rated current In (A) 63
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Power loss (W) 49
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 5400
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 7200
Total clearing I²t @Un AC (A²s) 25000
Rated breaking capacity I1 AC (kA) 50000
Weight (gr) 2340
Price List €283.18/pc
Quantity

Fuse DIN Motors 7,2kV 53x442 with striker 50A 80N

Reference 3010853.50.0 - Manufacturer SIBA
Class HH Motors
Rated current In (A) 50
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Power loss (W) 23
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 3400
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 7200
Total clearing I²t @Un AC (A²s) 16000
Rated breaking capacity I1 AC (kA) 50000
Weight (gr) 2278
Price List €274.62/pc
Quantity

Fuse DIN Motors 7,2kV 53x442 with striker 100A 80N

Reference 3010853.100.0 - Manufacturer SIBA
Class HH Motors
Rated current In (A) 100
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Power loss (W) 74
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 14000
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 7200
Total clearing I²t @Un AC (A²s) 65000
Rated breaking capacity I1 AC (kA) 50000
Weight (gr) 2300
Price List €321.27/pc
Quantity

Fuse 7,2kV 53x442 back-up with striker 6,3A 80N

Reference 3010813.6,3.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 6,3
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Power loss (W) 12
Resistance (ohm) 0,22
Fuse Dimension (mm) 67x442
Melting I²t value (A²s) 27
Minimum breaking current (A) 22
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 6264
Total clearing I²t @Un AC (A²s) 245
Rated breaking capacity I1 AC (kA) 80000
Price List €536.01/pc
Quantity

Fuse 7,2kV 53x442 back-up with striker 50A 80N

Reference 3010813.50.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 50
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Power loss (W) 41
Resistance (ohm) 0,012
Fuse Dimension (mm) 67x442
Melting I²t value (A²s) 4600
Minimum breaking current (A) 170
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 6264
Total clearing I²t @Un AC (A²s) 42000
Rated breaking capacity I1 AC (kA) 80000
Weight (gr) 2460
Price List €102.90/pc
Quantity

Fuse 7,2kV 53x442 back-up with striker 40A 80N

Reference 3010813.40.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 40
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Power loss (W) 36
Resistance (ohm) 0,016
Fuse Dimension (mm) 67x442
Melting I²t value (A²s) 2400
Minimum breaking current (A) 140
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 6264
Total clearing I²t @Un AC (A²s) 22000
Rated breaking capacity I1 AC (kA) 80000
Weight (gr) 2460
Price List €269.17/pc
Quantity

Fuse 12kV 67x442 back-up with striker 100A 80N

Reference 3010513.100.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 100
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 91
Resistance (ohm) 6,5
Fuse Dimension (mm) 67x442
Melting I²t value (A²s) 28000
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 10440
Total clearing I²t @Un AC (A²s) 210000
Rated breaking capacity I1 AC (kA) 63000
Price List €569.98/pc
Quantity

Fuse 12kV 85x442 back-up with striker 160ARC140 80N

Reference 3010313.160.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 160
Rated Voltage Un AC (V) 6000
Applicable standards IEC
Power loss (W) 117
Resistance (ohm) 0,004
Fuse Dimension (mm) 85x442
Melting I²t value (A²s) 78000
Minimum breaking current (A) 600
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 5220
Total clearing I²t @Un AC (A²s) 650000
Rated breaking capacity I1 AC (kA) 80000
Weight (gr) 5730
Price List €263.02/pc
Quantity

Fuse 12kV 87x442 back-up striker no temp.lim250ARC200

Reference 3010314.250LM.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 250
Rated Voltage Un AC (V) 6000
Applicable standards IEC
Power loss (W) 148
Resistance (ohm) 0,0024
Fuse Dimension (mm) 85x442
Melting I²t value (A²s) 265700
Minimum breaking current (A) 1000
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 5220
Total clearing I²t @Un AC (A²s) 1800000
Rated breaking capacity I1 AC (kA) 80000
Price List €606.86/pc
Quantity

Fuse 12kV 87x442 full range with striker 125A 80N

Reference 3010303.125.0 - Manufacturer SIBA
Class HHD full
Rated current In (A) 125
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 122
Resistance (ohm) 4,8
Fuse Dimension (mm) 87x442
Melting I²t value (A²s) 39200
Fuse Connection/Terminal type Cylindrical
Total clearing I²t @Un AC (A²s) 141000
Rated breaking capacity I1 AC (kA) 80000
Price List €1,535.96/pc
Quantity

Fuse 12kV 87x442 full range with striker 112A 80N

Reference 3010303.112.0 - Manufacturer SIBA
Class HHD full
Rated current In (A) 112
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 112
Resistance (ohm) 5,6
Fuse Dimension (mm) 87x442
Melting I²t value (A²s) 28800
Fuse Connection/Terminal type Cylindrical
Total clearing I²t @Un AC (A²s) 104000
Rated breaking capacity I1 AC (kA) 80000
Price List €1,519.17/pc
Quantity

Fuse 12kV 87x442 full range with striker 100A 80N

Reference 3010303.100.0 - Manufacturer SIBA
Class HHD full
Rated current In (A) 100
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 122
Resistance (ohm) 7,5
Fuse Dimension (mm) 87x442
Melting I²t value (A²s) 16200
Fuse Connection/Terminal type Cylindrical
Total clearing I²t @Un AC (A²s) 59000
Rated breaking capacity I1 AC (kA) 80000
Price List €1,421.81/pc
Quantity

Fuse DIN Motors 12kV 67x442 with striker 80A 80N

Reference 3010253.80.0 - Manufacturer SIBA
Class HH Motors
Rated current In (A) 80
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 105
Fuse Dimension (mm) 67x442
Melting I²t value (A²s) 6200
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 12000
Total clearing I²t @Un AC (A²s) 45000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 3660
Price List €236.85/pc
Quantity

Fuse DIN Motors 12kV 67x442 with striker 125A 80N

Reference 3010253.125.0 - Manufacturer SIBA
Class HH Motors
Rated current In (A) 125
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 115
Fuse Dimension (mm) 67x442
Melting I²t value (A²s) 25000
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 12000
Total clearing I²t @Un AC (A²s) 180000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 3660
Price List €309.50/pc
Quantity

Fuse DIN Motors 12kV 67x442 with striker 100A 80N

Reference 3010253.100.0 - Manufacturer SIBA
Class HH Motors
Rated current In (A) 100
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 107
Fuse Dimension (mm) 67x442
Melting I²t value (A²s) 14000
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 12000
Total clearing I²t @Un AC (A²s) 101000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 3660
Price List €282.51/pc
Quantity

Fuse 12kV 85x442 SSK with striker 125A 80N

Reference 3010343.125.0 - Manufacturer SIBA
Class HH SSK
Rated current In (A) 125
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 128
Resistance (ohm) 4,8
Fuse Dimension (mm) 85x442
Melting I²t value (A²s) 39000
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 12000
Total clearing I²t @Un AC (A²s) 323000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 5720
Price List €544.45/pc
Quantity

Fuse 12kV 67x442 SSK with striker 80A 80N

Reference 3010243.80.0 - Manufacturer SIBA
Class HH SSK
Rated current In (A) 80
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 72
Resistance (ohm) 8,7
Fuse Dimension (mm) 67x442
Melting I²t value (A²s) 12800
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 12000
Total clearing I²t @Un AC (A²s) 103000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 3680
Price List €385.33/pc
Quantity

Fuse 12kV 85x442 SSK with striker 160A 80N

Reference 3010343.160.0 - Manufacturer SIBA
Class HH SSK
Rated current In (A) 160
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 125
Resistance (ohm) 4,5
Fuse Dimension (mm) 85x442
Melting I²t value (A²s) 50000
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 12000
Total clearing I²t @Un AC (A²s) 405000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 5720
Price List €305.99/pc
Quantity

Fuse DIN Motors 12kV 85x442 with striker 160A 80N

Reference 3010353.160.0 - Manufacturer SIBA
Class HH Motors
Rated current In (A) 160
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 126
Fuse Dimension (mm) 85x442
Melting I²t value (A²s) 64000
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 12000
Total clearing I²t @Un AC (A²s) 417000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 5600
Price List €389.81/pc
Quantity

Fuse DIN Motors 12kV 85x442 +striker no temp-limit 200A

Reference 3010354.200.0 - Manufacturer SIBA
Class HH Motors
Rated current In (A) 200
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 134
Fuse Dimension (mm) 85x442
Melting I²t value (A²s) 121000
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 12000
Total clearing I²t @Un AC (A²s) 789000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 5671
Price List €489.09/pc
Quantity

Fuse DIN Motors 12kV 87x442 striker no temp-limit 250A

Reference 3010354.250LM.0 - Manufacturer SIBA
Class HH Motors
Rated current In (A) 250
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 120
Fuse Dimension (mm) 87x442
Melting I²t value (A²s) 307000
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 12000
Total clearing I²t @Un AC (A²s) 1900000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 5671
Price List €666.93/pc
Quantity

Fuse 12kV 67x442 back-up with striker 80A 80N

Reference 3010213.80.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 80
Rated Voltage Un AC (V) 6000
Applicable standards IEC
Power loss (W) 69
Resistance (ohm) 0,0083
Fuse Dimension (mm) 67x442
Melting I²t value (A²s) 17500
Minimum breaking current (A) 280
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 5220
Total clearing I²t @Un AC (A²s) 240000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 3680
Price List €506.10/pc
Quantity

Fuse 7,2kV 53x442 back-up with striker 3,15A 80N

Reference 3010813.3,15.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 3,15
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Power loss (W) 5,5
Resistance (ohm) 0,42
Fuse Dimension (mm) 67x442
Melting I²t value (A²s) 17
Minimum breaking current (A) 24
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 6264
Total clearing I²t @Un AC (A²s) 48
Rated breaking capacity I1 AC (kA) 80000
Weight (gr) 2460
Price List €88.39/pc
Quantity

Fuse 7,2kV 53x442 back-up with striker 25A 80N

Reference 3010813.25.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 25
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Power loss (W) 23
Resistance (ohm) 0,026
Fuse Dimension (mm) 67x442
Melting I²t value (A²s) 920
Minimum breaking current (A) 90
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 6264
Total clearing I²t @Un AC (A²s) 8200
Rated breaking capacity I1 AC (kA) 80000
Weight (gr) 2470
Price List €95.15/pc
Quantity

Fuse 7,2kV 53x442 back-up with striker 20A 80N

Reference 3010813.20.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 20
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Power loss (W) 19
Resistance (ohm) 0,034
Fuse Dimension (mm) 67x442
Melting I²t value (A²s) 540
Minimum breaking current (A) 70
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 6264
Total clearing I²t @Un AC (A²s) 4900
Rated breaking capacity I1 AC (kA) 80000
Weight (gr) 2460
Price List €94.54/pc
Quantity

Fuse 12kV 67x442 back-up with striker 125ARC110 80N

Reference 3010213.125.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 125
Rated Voltage Un AC (V) 6000
Applicable standards IEC
Power loss (W) 111
Resistance (ohm) 0,0062
Fuse Dimension (mm) 67x442
Melting I²t value (A²s) 38000
Minimum breaking current (A) 390
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 5220
Total clearing I²t @Un AC (A²s) 181500
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 3720
Price List €330.00/pc
Quantity

Fuse 7,2kV 53x442 back-up with striker 2A 80N

Reference 3010813.2.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 2
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Power loss (W) 5
Resistance (ohm) 0,935
Fuse Dimension (mm) 67x442
Melting I²t value (A²s) 3,2
Minimum breaking current (A) 16
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 6264
Total clearing I²t @Un AC (A²s) 12
Rated breaking capacity I1 AC (kA) 80000
Weight (gr) 2460
Price List €590.29/pc
Quantity

Fuse 12kV 67x442 back-up with striker 63A 80N

Reference 3010213.63.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 63
Rated Voltage Un AC (V) 6000
Applicable standards IEC
Power loss (W) 62
Resistance (ohm) 0,0117
Fuse Dimension (mm) 67x442
Melting I²t value (A²s) 8700
Minimum breaking current (A) 210
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 5220
Total clearing I²t @Un AC (A²s) 67000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 3660
Price List €224.99/pc
Quantity

Fuse 7,2kV 53x442 back-up with striker 10A 80N

Reference 3010813.10.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 10
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Power loss (W) 19
Resistance (ohm) 0,14
Fuse Dimension (mm) 67x442
Melting I²t value (A²s) 68
Minimum breaking current (A) 34
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 6264
Total clearing I²t @Un AC (A²s) 610
Rated breaking capacity I1 AC (kA) 80000
Weight (gr) 2460
Price List €89.32/pc
Quantity

Fuse 12kV 67x442 back-up with striker 125A 80N

Reference 3010513.125.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 125
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 99
Resistance (ohm) 5,9
Fuse Dimension (mm) 67x442
Melting I²t value (A²s) 38000
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 10440
Total clearing I²t @Un AC (A²s) 300000
Rated breaking capacity I1 AC (kA) 63000
Price List €423.97/pc
Quantity

Fuse 12kV 67x442 back-up with striker 63A 80N

Reference 3010513.63.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 63
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 63
Resistance (ohm) 12
Fuse Dimension (mm) 67x442
Melting I²t value (A²s) 10700
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 10440
Total clearing I²t @Un AC (A²s) 66000
Rated breaking capacity I1 AC (kA) 63000
Price List €360.46/pc
Quantity

Fuse 12kV 67x442 back-up with striker 80A 80N

Reference 3010513.80.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 80
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 76
Resistance (ohm) 8,5
Fuse Dimension (mm) 67x442
Melting I²t value (A²s) 21000
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 10440
Total clearing I²t @Un AC (A²s) 140000
Rated breaking capacity I1 AC (kA) 63000
Price List €365.20/pc
Quantity

Fuse 7,2kV 53x442 back-up with striker 31,5A 80N

Reference 3010813.31,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 31,5
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Power loss (W) 29
Resistance (ohm) 0,021
Fuse Dimension (mm) 67x442
Melting I²t value (A²s) 1400
Minimum breaking current (A) 110
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 6264
Total clearing I²t @Un AC (A²s) 12500
Rated breaking capacity I1 AC (kA) 80000
Weight (gr) 2460
Price List €152.12/pc
Quantity
Product added to compare.
Product added to wishlist