Home

Fuse 17,5kV 53x367 back-up with striker 6,3A 80N

Reference 3017613.6,3.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 6,3
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 22
Resistance (ohm) 0,402
Fuse Dimension (mm) 53x367
Melting I²t value (A²s) 27
Minimum breaking current (A) 22
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 520
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 1980
Price List €70.08/pc
Quantity

Fuse 17,5kV 67x367 back-up with striker 31,5A 80N

Reference 3017713.31,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 31,5
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 54
Resistance (ohm) 0,039
Fuse Dimension (mm) 67x367
Melting I²t value (A²s) 1400
Minimum breaking current (A) 110
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 9800
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 3090
Price List €91.35/pc
Quantity

Fuse 17,5kV 67x367 back-up with striker 40A 80N

Reference 3017713.40.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 40
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 66
Resistance (ohm) 0,029
Fuse Dimension (mm) 67x367
Melting I²t value (A²s) 2500
Minimum breaking current (A) 140
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 17500
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 3090
Price List €101.89/pc
Quantity

Fuse 17,5kV 67x367 back-up with striker 50A 80N

Reference 3017713.50.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 50
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 75
Resistance (ohm) 0,021
Fuse Dimension (mm) 67x367
Melting I²t value (A²s) 4700
Minimum breaking current (A) 170
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 33000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 3090
Price List €126.20/pc
Quantity

Fuse 17,5kV 67x367 back-up with striker 63A 80N

Reference 3017713.63.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 63
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 92
Resistance (ohm) 0,016
Fuse Dimension (mm) 67x367
Melting I²t value (A²s) 8700
Minimum breaking current (A) 210
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 61400
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 3090
Price List €137.05/pc
Quantity

Fuse 17,5kV 85x367 back-up with striker 100ARC90 80N

Reference 3017813.100.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 100
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 109
Resistance (ohm) 0,0087
Fuse Dimension (mm) 85x367
Melting I²t value (A²s) 28000
Minimum breaking current (A) 320
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 199000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 4790
Price List €186.99/pc
Quantity

Fuse 17,5kV 85x367 back-up with striker 125ARC105 80N

Reference 3017813.125.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 125
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 116
Resistance (ohm) 0,0067
Fuse Dimension (mm) 85x367
Melting I²t value (A²s) 47400
Minimum breaking current (A) 390
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 335000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 4790
Price List €228.84/pc
Quantity

Fuse 17,5kV 85x367 back-up with striker 160ARC112 80N

Reference 3017813.160.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 160
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 128
Resistance (ohm) 0,0059
Fuse Dimension (mm) 85x367
Melting I²t value (A²s) 62000
Minimum breaking current (A) 600
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 595000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 4790
Price List €263.31/pc
Quantity

Fuse 17,5kV 85x367 back-up with striker 80ARC75 80N

Reference 3017813.80.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 80
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 96
Resistance (ohm) 0,011
Fuse Dimension (mm) 85x367
Melting I²t value (A²s) 17500
Minimum breaking current (A) 280
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 123300
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 4790
Price List €184.84/pc
Quantity

Fuse 17,5kV 85x367back-up con perc no lim.temp 120N 100A

Reference 3017814.100.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 100
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 109
Resistance (ohm) 0,0087
Fuse Dimension (mm) 85x367
Melting I²t value (A²s) 28000
Minimum breaking current (A) 320
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 199000
Rated breaking capacity I1 AC (kA) 63000
Price List €320.39/pc
Quantity

Fuse 17,5kV 85x367back-up striker no temp.lim200ARC125

Reference 3017814.200.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 200
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 118
Resistance (ohm) 0,0051
Fuse Dimension (mm) 85x367
Melting I²t value (A²s) 146000
Minimum breaking current (A) 800
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 1166000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 4800
Price List €263.46/pc
Quantity

Fuse 17,5kV 53x192 back-up no striker 0,5A

Reference 3017911.0,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 0,5
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 8,1
Resistance (ohm) 29,48
Fuse Dimension (mm) 53x192
Melting I²t value (A²s) 1,6
Minimum breaking current (A) 5
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 5,9
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 1200
Price List €127.96/pc
Quantity

Fuse 17,5kV 53x192 back-up no striker 1A

Reference 3017911.1.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 1
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 6,2
Resistance (ohm) 4,64
Fuse Dimension (mm) 53x192
Melting I²t value (A²s) 0,63
Minimum breaking current (A) 8
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 1,8
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 1200
Price List €127.96/pc
Quantity

Fuse 17,5kV 53x192 back-up without striker 2,5A

Reference 3017911.2,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 2,5
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Fuse Dimension (mm) 53x192
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 1200
Price List €128.18/pc
Quantity

Fuse 17,5kV 53x192 back-up without striker 2A

Reference 3017911.2.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 2
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Fuse Dimension (mm) 53x192
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 1200
Price List €128.18/pc
Quantity

Fuse 17,5kV 53x192 back-up without striker 3A

Reference 3017911.3.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 3
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Fuse Dimension (mm) 53x192
Minimum breaking current (A) 63000
Fuse Connection/Terminal type Cylindrical
Rated breaking capacity I1 AC (kA) 15225
Weight (gr) 1200
Price List €33.39/pc
Quantity

Fuse 24kV 53x292 back-up with striker 10A 80N

Reference 3018013.10.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 10
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 52
Resistance (ohm) 0,352
Fuse Dimension (mm) 53x292
Melting I²t value (A²s) 68
Minimum breaking current (A) 34
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 20880
Total clearing I²t @Un AC (A²s) 880
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 1640
Price List €131.02/pc
Quantity

Fuse 24kV 53x292 TV without striker 4A

Reference 3018011.4.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 4
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Fuse Dimension (mm) 53x292
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 20880
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 1640
Price List €90.94/pc
Quantity

Fuse 24kV 53x292 TV without striker 2A

Reference 3018011.2.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 2
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Fuse Dimension (mm) 53x292
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 20880
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 1700
Price List €90.53/pc
Quantity

Fuse 24kV 53x292 TV no striker 1A

Reference 3018011.1.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 1
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 8,6
Resistance (ohm) 6,45
Fuse Dimension (mm) 53x292
Melting I²t value (A²s) 0,63
Minimum breaking current (A) 8
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 20880
Total clearing I²t @Un AC (A²s) 1,8
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 1700
Price List €90.43/pc
Quantity

Fuse 17,5kV 53x192 back-up without striker 3,15A

Reference 3017911.3,15.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 3,15
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Fuse Dimension (mm) 53x192
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 1200
Price List €88.82/pc
Quantity

Fuse 24kV 53x292 TV no striker 0,8A

Reference 3018011.0,8.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 0,8
Rated Voltage Un AC (V) 2400
Applicable standards IEC
Fuse Dimension (mm) 53x292
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 2400
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 1700
Price List €29.60/pc
Quantity

Fuse 24kV 53x292 TV no striker 0,5A

Reference 3018011.0,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 0,5
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 11,2
Resistance (ohm) 40,55
Fuse Dimension (mm) 53x292
Melting I²t value (A²s) 1,6
Minimum breaking current (A) 5
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 20880
Total clearing I²t @Un AC (A²s) 5,9
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 1700
Price List €71.26/pc
Quantity

Fuse 17,5kV 53x192 back-up with striker 6,3A 80N

Reference 3017913.6,3.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 6,3
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 22
Resistance (ohm) 0,402
Fuse Dimension (mm) 53x192
Melting I²t value (A²s) 27
Minimum breaking current (A) 22
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 520
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 1200
Price List €128.89/pc
Quantity

Fuse 17,5kV 53x192 back-up with striker 5A 80N

Reference 3017913.5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 5
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 11
Resistance (ohm) 0,314
Fuse Dimension (mm) 53x192
Melting I²t value (A²s) 40
Minimum breaking current (A) 40
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 125
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 1200
Price List €445.41/pc
Quantity

Fuse 17,5kV 53x192 back-up with striker 4A 80N

Reference 3017913.4.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 4
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 16
Resistance (ohm) 0,69
Fuse Dimension (mm) 53x192
Melting I²t value (A²s) 31
Minimum breaking current (A) 32
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 90
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 1200
Price List €445.46/pc
Quantity

Fuse 17,5kV 53x192 back-up with striker 3,15A 80N

Reference 3017913.3,15.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 3,15
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 13
Resistance (ohm) 0,92
Fuse Dimension (mm) 53x192
Melting I²t value (A²s) 17
Minimum breaking current (A) 24
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 48
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 1200
Price List €81.72/pc
Quantity

Fuse 17,5kV 53x192 back-up with striker 2A 80N

Reference 3017913.2.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 2
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 11
Resistance (ohm) 2,06
Fuse Dimension (mm) 53x192
Melting I²t value (A²s) 3,2
Minimum breaking current (A) 16
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 9,8
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 1200
Price List €125.36/pc
Quantity

Fuse 17,5kV 53x192 back-up with striker 2,5A 80N

Reference 3017913.2,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 2,5
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 12
Resistance (ohm) 1,4
Fuse Dimension (mm) 53x192
Melting I²t value (A²s) 7,2
Minimum breaking current (A) 20
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 24
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 1220
Price List €445.51/pc
Quantity

Fuse 17,5kV 53x192 back-up with striker 10A 80N

Reference 3017913.10.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 10
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 36
Resistance (ohm) 0,256
Fuse Dimension (mm) 53x192
Melting I²t value (A²s) 68
Minimum breaking current (A) 34
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 680
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 1200
Price List €226.23/pc
Quantity

Fuse 17,5kV 53x192 back-up without striker 6,3A

Reference 3017911.6,3.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 6,3
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Fuse Dimension (mm) 53x192
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 1190
Price List €128.64/pc
Quantity

Fuse 7,2kV 63,5x254 F01 oiltight 112A

Reference 3013236.112.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 112
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Fuse Dimension (mm) 63,5x254
Melting I²t value (A²s) 28300
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 7200
Total clearing I²t @Un AC (A²s) 278000
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 1780
Price List €264.51/pc
Quantity

Fuse 7,2kV 63,5x254 F01 oiltight 20A

Reference 3013236.20.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 20
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Fuse Dimension (mm) 63,5x254
Melting I²t value (A²s) 290
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 7200
Total clearing I²t @Un AC (A²s) 2900
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 1780
Price List €218.43/pc
Quantity

Fuse Motors DIN-ANSI 7,2kV double body 2x85x442

Reference 3011155.24R.0 - Manufacturer SIBA
Class HH Motors
Rated current In (A) 450
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Power loss (W) 236
R-Rating 24
Fuse Dimension (mm) 2x 85x442
Melting I²t value (A²s) 353000
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 7200
Total clearing I²t @Un AC (A²s) 678000
Rated breaking capacity I1 AC (kA) 50000
Weight (gr) 11480
Price List €857.61/pc
Quantity

Fuse 7,2kV 63,5x254 F01 oiltight 10A

Reference 3013236.10.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 10
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Fuse Dimension (mm) 63,5x254
Melting I²t value (A²s) 50
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 7200
Total clearing I²t @Un AC (A²s) 450
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 1780
Price List €217.59/pc
Quantity

Fuse 7,2kV 63,5x254 F01 oiltight 100A

Reference 3013236.100.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 100
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Fuse Dimension (mm) 63,5x254
Melting I²t value (A²s) 22200
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 7200
Total clearing I²t @Un AC (A²s) 218500
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 1780
Price List €262.60/pc
Quantity
Product added to compare.
Product added to wishlist