Fuse SQB1 1500VDC gPV UL2579 USA knife contacts +ind. 100A

Reference 2004529.100.0 - Manufacturer SIBA
Class gPV
Rated current In (A) 100
Dimension SQB1
Applicable standards IEC, UL
Power loss (W) 25
Rated Voltage Un DC (V) 1500
Time costant L/R (ms) 3
Melting I²t value (A²s) 1650
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 9900
Price List €180.77/pc
Quantity

Fuse SQB1 1500VDC gPV UL2579 USA knife contacts +ind. 125A

Reference 2004529.125.0 - Manufacturer SIBA
Class gPV
Rated current In (A) 125
Dimension SQB1
Applicable standards IEC, UL
Power loss (W) 27
Rated Voltage Un DC (V) 1500
Time costant L/R (ms) 3
Melting I²t value (A²s) 2950
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 18000
Product available on request Ask for more information

Fuse SQB1 1500VDC gPV UL2579 USA knife contacts +ind. 200A

Reference 2004529.200.0 - Manufacturer SIBA
Class gPV
Rated current In (A) 200
Dimension SQB1
Applicable standards IEC, UL
Power loss (W) 44
Rated Voltage Un DC (V) 1500
Time costant L/R (ms) 3
Melting I²t value (A²s) 14300
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 85000
Product available on request Ask for more information

Fuse SQB1 1500VDC gPV UL2579 USA knife contacts +ind. 50A

Reference 2004529.50.0 - Manufacturer SIBA
Class gPV
Rated current In (A) 50
Dimension SQB1
Applicable standards IEC, UL
Power loss (W) 18
Rated Voltage Un DC (V) 1500
Time costant L/R (ms) 3
Melting I²t value (A²s) 361
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 2200
Product available on request Ask for more information

Fuse SQB1 1500VDC gPV UL2579 USA knife contacts +ind. 63A

Reference 2004529.63.0 - Manufacturer SIBA
Class gPV
Rated current In (A) 63
Dimension SQB1
Applicable standards IEC, UL
Power loss (W) 22
Rated Voltage Un DC (V) 1500
Time costant L/R (ms) 3
Melting I²t value (A²s) 480
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 2900
Product available on request Ask for more information

Fuse SQB1 1500VDC gPV UL2579 USA knife contacts +ind. 80A

Reference 2004529.80.0 - Manufacturer SIBA
Class gPV
Rated current In (A) 80
Dimension SQB1
Applicable standards IEC, UL
Power loss (W) 24
Rated Voltage Un DC (V) 1500
Time costant L/R (ms) 3
Melting I²t value (A²s) 1060
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 6400
Product available on request Ask for more information

Fuse NH1XL 1500V DC gBat US blade without ind. 100A

Reference 2004536.100.0 - Manufacturer SIBA
Class gBat, gR
Rated current In (A) 100
Dimension NH1XL
Applicable standards IEC, UL
Power loss (W) 25
Rated Voltage Un DC (V) 1500
Time costant L/R (ms) 3
Rated breaking capacity I1 DC (kA) 100000
Melting I²t value (A²s) 1650
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 9900
Product available on request Ask for more information

Fuse NH1XL 1500V DC gBat US blade without ind. 125A

Reference 2004536.125.0 - Manufacturer SIBA
Class gBat, gR
Rated current In (A) 125
Dimension NH1XL
Applicable standards IEC, UL
Power loss (W) 27
Rated Voltage Un DC (V) 1500
Time costant L/R (ms) 3
Rated breaking capacity I1 DC (kA) 100000
Melting I²t value (A²s) 2950
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 18000
Product available on request Ask for more information

Fuse NH1XL 1500V DC gBat US blade without ind.160A

Reference 2004536.160.0 - Manufacturer SIBA
Class gBat, gR
Rated current In (A) 160
Dimension NH1XL
Applicable standards IEC, UL
Power loss (W) 37
Rated Voltage Un DC (V) 1500
Time costant L/R (ms) 3
Rated breaking capacity I1 DC (kA) 100000
Melting I²t value (A²s) 5600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 34000
Product available on request Ask for more information

Fuse NH1XL 1500V DC gBat US blade without ind. 200A

Reference 2004536.200.0 - Manufacturer SIBA
Class gBat, gR
Rated current In (A) 200
Dimension NH1XL
Applicable standards IEC, UL
Power loss (W) 44
Rated Voltage Un DC (V) 1500
Time costant L/R (ms) 3
Rated breaking capacity I1 DC (kA) 100000
Melting I²t value (A²s) 14300
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 85000
Price List €1,114.60/pc
Quantity

Fuse NH1XL 1500V DC gBat US blade without ind. 50A

Reference 2004536.50.0 - Manufacturer SIBA
Class gBat, gR
Rated current In (A) 50
Dimension NH1XL
Applicable standards IEC, UL
Power loss (W) 18
Rated Voltage Un DC (V) 1500
Time costant L/R (ms) 3
Rated breaking capacity I1 DC (kA) 100000
Melting I²t value (A²s) 361
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 2200
Product available on request Ask for more information

Fuse NH1XL 1500V DC gBat US blade without ind. 63A

Reference 2004536.63.0 - Manufacturer SIBA
Class gBat, gR
Rated current In (A) 63
Dimension NH1XL
Applicable standards IEC, UL
Power loss (W) 22
Rated Voltage Un DC (V) 1500
Time costant L/R (ms) 3
Rated breaking capacity I1 DC (kA) 100000
Melting I²t value (A²s) 480
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 2900
Product available on request Ask for more information

Fuse NH1XL 1500V DC gBat US blade without ind. 80A

Reference 2004536.80.0 - Manufacturer SIBA
Class gBat, gR
Rated current In (A) 80
Dimension NH1XL
Applicable standards IEC, UL
Power loss (W) 24
Rated Voltage Un DC (V) 1500
Time costant L/R (ms) 3
Rated breaking capacity I1 DC (kA) 100000
Melting I²t value (A²s) 1060
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 6400
Product available on request Ask for more information

Fuse NH1XL 1500V DC gBat US with ind. 100A

Reference 2004537.100.0 - Manufacturer SIBA
Class gBat, gR
Rated current In (A) 100
Dimension NH1XL
Applicable standards IEC, UL
Power loss (W) 25
Rated Voltage Un DC (V) 1500
Time costant L/R (ms) 3
Rated breaking capacity I1 DC (kA) 100000
Melting I²t value (A²s) 1650
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 9900
Product available on request Ask for more information

Fuse NH1XL 1500V DC gBat US with ind. 125A

Reference 2004537.125.0 - Manufacturer SIBA
Class gBat, gR
Rated current In (A) 125
Dimension NH1XL
Applicable standards IEC, UL
Power loss (W) 27
Rated Voltage Un DC (V) 1500
Time costant L/R (ms) 3
Rated breaking capacity I1 DC (kA) 100000
Melting I²t value (A²s) 2950
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 18000
Product available on request Ask for more information

Fuse NH1XL 1500V DC gBat US with ind. 160A

Reference 2004537.160.0 - Manufacturer SIBA
Class gBat, gR
Rated current In (A) 160
Dimension NH1XL
Applicable standards IEC, UL
Power loss (W) 37
Rated Voltage Un DC (V) 1500
Time costant L/R (ms) 3
Rated breaking capacity I1 DC (kA) 100000
Melting I²t value (A²s) 5600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 34000
Product available on request Ask for more information

Fuse NH1XL 1500V DC gBat US with ind. 200A

Reference 2004537.200.0 - Manufacturer SIBA
Class gBat, gR
Rated current In (A) 200
Dimension NH1XL
Applicable standards IEC, UL
Power loss (W) 44
Rated Voltage Un DC (V) 1500
Time costant L/R (ms) 3
Rated breaking capacity I1 DC (kA) 100000
Melting I²t value (A²s) 14300
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 85000
Price List €1,160.90/pc
Quantity

Fuse NH1XL 1500V DC gBat US with ind. 50A

Reference 2004537.50.0 - Manufacturer SIBA
Class gBat, gR
Rated current In (A) 50
Dimension NH1XL
Applicable standards IEC, UL
Power loss (W) 18
Rated Voltage Un DC (V) 1500
Time costant L/R (ms) 3
Rated breaking capacity I1 DC (kA) 100000
Melting I²t value (A²s) 361
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 2200
Product available on request Ask for more information

Fuse NH1XL 1500V DC gBat US with ind. 63A

Reference 2004537.63.0 - Manufacturer SIBA
Class gBat, gR
Rated current In (A) 63
Dimension NH1XL
Applicable standards IEC, UL
Power loss (W) 22
Rated Voltage Un DC (V) 1500
Time costant L/R (ms) 3
Rated breaking capacity I1 DC (kA) 100000
Melting I²t value (A²s) 480
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 2900
Product available on request Ask for more information

Fuse NH1XL 1500V DC gBat US with ind. 80A

Reference 2004537.80.0 - Manufacturer SIBA
Class gBat, gR
Rated current In (A) 80
Dimension NH1XL
Applicable standards IEC, UL
Power loss (W) 24
Rated Voltage Un DC (V) 1500
Time costant L/R (ms) 3
Rated breaking capacity I1 DC (kA) 100000
Melting I²t value (A²s) 1060
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 6400
Product available on request Ask for more information

Fuse NH00 gR/aR 500V with striker 20A

Reference 2000704.20.0 - Manufacturer SIBA
Class gR
Rated current In (A) 20
Rated Voltage Un AC (V) 500
Dimension NH00
Applicable standards IEC
Power loss (W) 5,7
Melting I²t value (A²s) 17
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 185
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 190
Price List €45.98/pc
Quantity

Fuse NH1 gG 500V with striker 35A

Reference 2000913.35.0 - Manufacturer SIBA
Class aM
Rated current In (A) 35
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 3,9
Melting I²t value (A²s) 3100
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 7610
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 410
Price List €23.92/pc
Quantity

Fuse NH1 gG 500V with striker 50A

Reference 2000913.50.0 - Manufacturer SIBA
Class aM
Rated current In (A) 50
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 5,1
Melting I²t value (A²s) 5900
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 13600
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 410
Price List €208.41/pc
Quantity

Fuse NH2 gR 500V with striker 100A

Reference 2001004.100.0 - Manufacturer SIBA
Class gR
Rated current In (A) 100
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC, UL
Power loss (W) 23
Melting I²t value (A²s) 920
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 7600
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 660
Product available on request Ask for more information
Product added to compare.
Product added to wishlist