Home

Fuse base 600V class J 3poles 200A

Reference M6J200A3101.0.0 - Manufacturer MARATHON
Rated current In (A) 200
Rated Voltage Un AC (V) 600
Dimension Classe J
Applicable standards UL
Fuse Connection/Terminal type US
Price List $669.58/pc
Quantity

Fuse holder 600V 600A UL with protection covers

Reference MFH6063DDCH.0.0 - Manufacturer MARATHON
Rated current In (A) 600
Rated Voltage Un AC (V) 600
Applicable standards UL
Rated Voltage Un DC (V) 600
Weight (gr) 957
Price List $284.45/pc
Quantity

Fuse holder 1500VDC 600A UL with protection covers

Reference MFH6153DDCH.0.0 - Manufacturer MARATHON
Rated current In (A) 600
Rated Voltage Un AC (V) 1000
Applicable standards UL
Rated Voltage Un DC (V) 1500
Weight (gr) 957
Price List $154.42/pc
Quantity

Fuse holder 600V 800A UL with protection covers

Reference MFH8065FFCH.0.0 - Manufacturer MARATHON
Rated current In (A) 800
Rated Voltage Un AC (V) 600
Applicable standards UL
Rated Voltage Un DC (V) 600
Weight (gr) 1360
Price List $354.56/pc
Quantity

M050 - Fuse 500V DC 10x38 15A

Reference 548.582.23.0.0 - Manufacturer FAULTRAP
Class EV full
Rated current In (A) 15
Power loss (W) 5,2
Rated Voltage Un DC (V) 500
Series name M050
Fuse Dimension (mm) 10x38
Fuse Connection/Terminal type Cylindrical
Product available on request Ask for more information

L108 - In-Line Rugged 10x85 Fuse + Holder 1500VDC 15A

Reference 587.152.07.0.0 - Manufacturer FAULTRAP
Class gPV
Rated current In (A) 15
Applicable standards IEC
Power loss (W) 3,6
Rated Voltage Un DC (V) 1500
Series name L108
Rated breaking capacity I1 DC (kA) 20000
Fuse Dimension (mm) 10x85
Melting I²t value (A²s) 29,2
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 329
Product available on request Ask for more information

EV65.1000 - Fuse 1000VDC 22x65 cylindrical 80A

Reference 587.419.17.0.0 - Manufacturer FAULTRAP
Class EV full
Rated current In (A) 80
Applicable standards UL
Power loss (W) 14,9
Rated Voltage Un DC (V) 1000
Time costant L/R (ms) 2,5
Series name EV65.1000
Rated breaking capacity I1 DC (kA) 25000
Fuse Dimension (mm) 22x65
Melting I²t value (A²s) 3000
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 1000
Total clearing I²t @Un AC (A²s) 8750
Product available on request Ask for more information

E103 - Fuse 10x38 1000VDC aBAT 12A

Reference 619.828.62.0.0 - Manufacturer FAULTRAP
Class aBat
Rated current In (A) 12
Applicable standards IEC
Power loss (W) 2,7
Rated Voltage Un DC (V) 1000
Series name E103
Rated breaking capacity I1 DC (kA) 20000
Fuse Dimension (mm) 10x38
Fuse Connection/Terminal type Cylindrical
Product available on request Ask for more information

L108 - In-Line Rugged 10x85 Fuse + Holder 1500VDC 12A

Reference 631.813.48.0.0 - Manufacturer FAULTRAP
Class gPV
Rated current In (A) 12
Applicable standards IEC
Power loss (W) 3,2
Rated Voltage Un DC (V) 1500
Series name L108
Rated breaking capacity I1 DC (kA) 20000
Fuse Dimension (mm) 10x85
Melting I²t value (A²s) 16,3
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 177
Product available on request Ask for more information

E103 - Fuse 10x38 500VDC aBAT 50A

Reference 638.553.07.0.0 - Manufacturer FAULTRAP
Class aBat
Rated current In (A) 50
Applicable standards IEC
Power loss (W) 6,4
Rated Voltage Un DC (V) 500
Series name E103
Rated breaking capacity I1 DC (kA) 20000
Fuse Dimension (mm) 10x38
Fuse Connection/Terminal type Cylindrical
Price List $4.39/pc
Quantity

L226 - In-Line Rugged 22x65 Fuse + Holder 1500VDC 40A

Reference 664.427.16.0.0 - Manufacturer FAULTRAP
Class gPV
Rated current In (A) 40
Applicable standards IEC
Power loss (W) 8
Rated Voltage Un DC (V) 1500
Series name L226
Rated breaking capacity I1 DC (kA) 10000
Fuse Dimension (mm) 22x65
Melting I²t value (A²s) 900
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 4000
Product available on request Ask for more information

L108 - In-Line Rugged 10x85 Fuse + Holder 1500VDC 16A

Reference 703.819.10.0.0 - Manufacturer FAULTRAP
Class gPV
Rated current In (A) 16
Applicable standards IEC
Power loss (W) 3,6
Rated Voltage Un DC (V) 1500
Series name L108
Rated breaking capacity I1 DC (kA) 20000
Fuse Dimension (mm) 10x85
Melting I²t value (A²s) 29,2
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 329
Product available on request Ask for more information
Product added to compare.
Product added to wishlist