Home

AB22 - Fuse 22x65 1000VDC aBat 80A

Reference 993.797.75.0.0 - Manufacturer FAULTRAP
Class aBat
Rated current In (A) 80
Applicable standards IEC
Power loss (W) 13.5
Rated Voltage Un DC (V) 1000
Time costant L/R (ms) 1-3
Series name AB22
Rated breaking capacity I1 DC (kA) 10
Fuse Dimension (mm) 22x65
Melting I²t value (A²s) 3030
Minimum breaking current (A) 640
Fuse Connection/Terminal type Cylindrical
Total clearing I²t @Un DC (A²s) 16600
Product available on request Ask for more information

M100 - Fuse 1000V DC 10x38 12A

Reference 993.569.98.0.0 - Manufacturer FAULTRAP
Class EV full
Rated current In (A) 12
Applicable standards UL
Power loss (W) 2
Rated Voltage Un DC (V) 1000
Series name M100
Fuse Dimension (mm) 10x38
Fixing dimensions M10
Fuse Connection/Terminal type Cylindrical
Product available on request Ask for more information

NR2B - Fuse DIN00 80mm aR 700VDC/690VAC with ind. lug 125A

Reference 993.324.88.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 125
Rated Voltage Un AC (V) 690
Dimension 000
Applicable standards IEC, UL
Power loss (W) 27.5
Rated Voltage Un DC (V) 700
Time costant L/R (ms) 2
Series name NR2B
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 2100
Fuse Connection/Terminal type Screw fixing
Fixing connection centres (mm) 80
Voltage of total clearing I2t test 700
Total clearing I²t @Un AC (A²s) 7700
Rated breaking capacity I1 AC (kA) 200000
Product available on request Ask for more information

20PV22 - Fuse 2000VDC gPV 22x85 inline 55A 6/8 AWG

Reference 992.157.21.0.0 - Manufacturer FAULTRAP
Class gPV
Rated current In (A) 55
Applicable standards IEC
Power loss (W) 13.5
Rated Voltage Un DC (V) 2000
Time costant L/R (ms) 1-3
Series name 20PV22
Rated breaking capacity I1 DC (kA) 50
Fuse Dimension (mm) 22x85
Melting I²t value (A²s) 1065
Fuse Connection/Terminal type In-line for copper cable
Product available on request Ask for more information

C100 - Fuse 690V aR size 1 M8 250A

Reference 952.201.47.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 250
Rated Voltage Un AC (V) 690
Dimension SQB2
Applicable standards IEC
Power loss (W) 38
Fixing dimensions M8
Melting I²t value (A²s) 4100
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 28000
Rated breaking capacity I1 AC (kA) 100000
Product available on request Ask for more information
Class aR
Rated current In (A) 630
Rated Voltage Un AC (V) 690
Dimension SQB2
Applicable standards IEC
Power loss (W) 84
Series name C200
Fixing dimensions M10
Melting I²t value (A²s) 55500
Fuse Connection/Terminal type Screw fixing
Total clearing I²t @Un AC (A²s) 383000
Rated breaking capacity I1 AC (kA) 200
Product available on request Ask for more information

B025 - Fuse 1000VDC aBat 300A - 100,3mm - Tin Plated

Reference 942.895.54.0.0 - Manufacturer FAULTRAP
Class aBat, aR
Rated current In (A) 300
Applicable standards IEC, UL
Power loss (W) 47
Rated Voltage Un DC (V) 1000
Time costant L/R (ms) 2
Series name B025
Rated breaking capacity I1 DC (kA) 100
Fuse Dimension (mm) 38x129
Melting I²t value (A²s) 23300
Minimum breaking current (A) 2400
Fuse Connection/Terminal type Screw fixing
Fixing connection centres (mm) 100
Total clearing I²t @Un AC (A²s) 51000
Price List €81.08/pc
Quantity
Product added to compare.
Product added to wishlist