All Products

B100 - Fuse 1000VDC aBat 630A - 152,7mm - Silver Plated

Reference 812.809.96.0.0 - Manufacturer FAULTRAP
Class aBat
Rated current In (A) 630
Applicable standards IEC, UL
Power loss (W) 120
Rated Voltage Un DC (V) 1000
Time costant L/R (ms) 2
Series name B100
Rated breaking capacity I1 DC (kA) 100000
Fuse Dimension (mm) 63,5x203,2
Melting I²t value (A²s) 108000
Minimum breaking current (A) 6300
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 1000
Total clearing I²t @Un AC (A²s) 324000
Product available on request Ask for more information

NRAB - Fuse 690V AC aR NH00 with indicator 200A

Reference 813.675.13.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 200
Rated Voltage Un AC (V) 690
Dimension NH00
Applicable standards IEC
Power loss (W) 48,5
Series name NRAB
Melting I²t value (A²s) 5370
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 770
Total clearing I²t @Un AC (A²s) 26200
Rated breaking capacity I1 AC (kA) 200000
Product available on request Ask for more information

BP22 -Fuse 22x65mm cylindrical 63A

Reference 820.572.76.0.0 - Manufacturer FAULTRAP
Class gBat, gR
Rated current In (A) 63
Applicable standards IEC, UL
Power loss (W) 1,6
Rated Voltage Un DC (V) 1000
Series name BP22
Rated breaking capacity I1 DC (kA) 100000
Fuse Dimension (mm) 22x65
Fuse Connection/Terminal type Cylindrical
Total clearing I²t @Un AC (A²s) 1660
Product available on request Ask for more information

M050 - Fuse 500V DC 10x38 20A

Reference 825.200.32.0.0 - Manufacturer FAULTRAP
Class EV full
Rated current In (A) 20
Power loss (W) 6,8
Rated Voltage Un DC (V) 500
Series name M050
Fuse Dimension (mm) 10x38
Fuse Connection/Terminal type Cylindrical
Product available on request Ask for more information

10TD - Fuse 10x38 400VAC aM/aR 25A

Reference 828.304.38.0.0 - Manufacturer FAULTRAP
Class aM, aR
Rated current In (A) 25
Rated Voltage Un AC (V) 400
Applicable standards IEC, UL
Series name 10TD
Fuse Dimension (mm) 10x38
Melting I²t value (A²s) 1320
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 400
Total clearing I²t @Un AC (A²s) 3670
Rated breaking capacity I1 AC (kA) 50000
Product available on request Ask for more information

B100 - Fuse 1000VDC aBat 630A - 2xM12 - Silver Plated

Reference 829.815.86.0.0 - Manufacturer FAULTRAP
Class aBat
Rated current In (A) 630
Applicable standards IEC, UL
Power loss (W) 120
Rated Voltage Un DC (V) 1000
Time costant L/R (ms) 2
Series name B100
Rated breaking capacity I1 DC (kA) 100000
Fuse Dimension (mm) 63,5x106,5
Fixing dimensions M12
Melting I²t value (A²s) 108000
Minimum breaking current (A) 6300
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 1000
Total clearing I²t @Un AC (A²s) 324000
Product available on request Ask for more information

ZVJM - Fuse holder 10x38 690VAC-1000VDC 1P

Reference 832.456.76.0.0 - Manufacturer FAULTRAP
Rated current In (A) 32
Rated Voltage Un AC (V) 690
Applicable standards IEC
Rated Voltage Un DC (V) 1000
Series name ZVJM
Fuse Dimension (mm) 10x38
Fuse Connection/Terminal type Cylindrical
Rated Power Acceptance 4
Number of poles 1
Weight (gr) 62
Price List €3.19/pc
Quantity

UR22 - Fuse 690V AC 22x58 fixing on pcb 20A

Reference 832.525.27.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 20
Rated Voltage Un AC (V) 690
Applicable standards IEC
Power loss (W) 6,1
Series name UR22
Melting I²t value (A²s) 21
Fuse Connection/Terminal type PCB Mount Terminals
Total clearing I²t @Un AC (A²s) 96
Rated breaking capacity I1 AC (kA) 200
Product available on request Ask for more information

P103 - Fuse 550V DC EV with pins 20 AMP

Reference 833.004.58.0.0 - Manufacturer FAULTRAP
Rated current In (A) 20
Applicable standards IEC
Power loss (W) 3,9
Rated Voltage Un DC (V) 550
Time costant L/R (ms) 2
Series name P103
Rated breaking capacity I1 DC (kA) 20000
Fuse Dimension (mm) 10x38
Melting I²t value (A²s) 33
Voltage of total clearing I2t test 550
Total clearing I²t @Un AC (A²s) 140
Product available on request Ask for more information

20PV22 - Fuse 2000VDC gPV 22x85 12A

Reference 833.361.58.0.0 - Manufacturer FAULTRAP
Class gPV
Rated current In (A) 12
Applicable standards IEC
Power loss (W) 4
Rated Voltage Un DC (V) 2000
Time costant L/R (ms) 1-3
Series name 20PV22
Rated breaking capacity I1 DC (kA) 50
Fuse Dimension (mm) 22x85
Melting I²t value (A²s) 23
Fuse Connection/Terminal type Cylindrical
Product available on request Ask for more information

NR2A-Fuse 000/80 aR 700VDC/690VAC with ind. w/o lug 315A

Reference 834.560.26.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 315
Rated Voltage Un AC (V) 690
Dimension 000
Applicable standards IEC
Power loss (W) 70
Rated Voltage Un DC (V) 700
Time costant L/R (ms) 2
Series name NR2A
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 16450
Fuse Connection/Terminal type Screw fixing
Fixing connection centres (mm) 80
Voltage of total clearing I2t test 700
Total clearing I²t @Un AC (A²s) 60000
Rated breaking capacity I1 AC (kA) 200000
Price List €27.32/pc
Quantity

A145 - Fuse 14x51 690VAC aR 25A

Reference 836.007.31.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 25
Rated Voltage Un AC (V) 690
Applicable standards IEC
Power loss (W) 8.5
Series name A145
Fuse Dimension (mm) 14x51
Melting I²t value (A²s) 36
Fuse Connection/Terminal type Cylindrical
Total clearing I²t @Un AC (A²s) 355
Rated breaking capacity I1 AC (kA) 200
Price List €4.16/pc
Quantity

ZLIY - Fuse base metal/ceramic NH3L 1500V

Reference 837.607.45.0.0 - Manufacturer FAULTRAP
Rated current In (A) 630
Rated Voltage Un AC (V) 1000
Dimension NH3L
Applicable standards IEC
Rated Voltage Un DC (V) 1500
Series name ZLIY
Fuse Connection/Terminal type NH knife
Rated Power Acceptance 60
Number of poles 1
Weight (gr) 1018
Price List €152.66/pc
Quantity

UR22 - Fuse 690V AC 22x58 cylindrical 20A

Reference 838.770.26.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 20
Rated Voltage Un AC (V) 550
Applicable standards IEC, UL
Power loss (W) 6,1
Series name UR22
Melting I²t value (A²s) 21
Fuse Connection/Terminal type Cylindrical
Total clearing I²t @Un AC (A²s) 96
Rated breaking capacity I1 AC (kA) 200
Product available on request Ask for more information
Filter by
Manufacturer
Series name
Class
Rated Voltage Un AC (V)
Rated Voltage Un DC (V)
Rated insultaion voltage AC (V)
Rated insulated voltage DC (V)
Applicable standards
Product added to compare.
Product added to wishlist