All Products

Fuse DIN000 80mm aR 690V UL with indicator, w/o lug 225A

Reference 2028220.225.0 - Manufacturer SIBA
Class aR
Rated current In (A) 225
Rated Voltage Un AC (V) 690
Dimension 000
Applicable standards IEC, UL
Power loss (W) 44
Melting I²t value (A²s) 6600
Fuse Connection/Terminal type Screw fixing
Fixing connection centres (mm) 80
Voltage of total clearing I2t test 660
Total clearing I²t @Un AC (A²s) 37000
Rated breaking capacity I1 AC (kA) 200000
Weight (gr) 130
Price List €282.25/pc
Quantity

Fuse DIN000 80mm aR 690V UL with indicator, w/o lug 250A

Reference 2028220.250.0 - Manufacturer SIBA
Class aR
Rated current In (A) 250
Rated Voltage Un AC (V) 690
Dimension 000
Applicable standards IEC, UL
Power loss (W) 47
Melting I²t value (A²s) 8000
Fuse Connection/Terminal type Screw fixing
Fixing connection centres (mm) 80
Voltage of total clearing I2t test 660
Total clearing I²t @Un AC (A²s) 44000
Rated breaking capacity I1 AC (kA) 200000
Weight (gr) 130
Price List €77.45/pc
Quantity

Fuse DIN000 80mm aR 690V UL with indicator, w/o lug 315A

Reference 2028220.315.0 - Manufacturer SIBA
Class aR
Rated current In (A) 315
Rated Voltage Un AC (V) 690
Dimension 000
Applicable standards IEC, UL
Power loss (W) 58
Melting I²t value (A²s) 14000
Fuse Connection/Terminal type Screw fixing
Fixing connection centres (mm) 80
Voltage of total clearing I2t test 660
Total clearing I²t @Un AC (A²s) 77000
Rated breaking capacity I1 AC (kA) 200000
Weight (gr) 120
Price List €84.53/pc
Quantity

Fuse DIN000 80mm aR 690V with indicator, w/o lug 32A

Reference 2028220.32.0 - Manufacturer SIBA
Class aR
Rated current In (A) 32
Rated Voltage Un AC (V) 690
Dimension 000
Applicable standards IEC
Power loss (W) 8
Melting I²t value (A²s) 52
Fuse Connection/Terminal type Screw fixing
Fixing connection centres (mm) 80
Voltage of total clearing I2t test 660
Total clearing I²t @Un AC (A²s) 290
Rated breaking capacity I1 AC (kA) 200000
Weight (gr) 130
Price List €46.27/pc
Quantity

Fuse DIN000 80mm aR 690V UL with indicator, w/o lug 35A

Reference 2028220.35.0 - Manufacturer SIBA
Class aR
Rated current In (A) 35
Rated Voltage Un AC (V) 690
Dimension 000
Applicable standards IEC, UL
Power loss (W) 9
Melting I²t value (A²s) 66
Fuse Connection/Terminal type Screw fixing
Fixing connection centres (mm) 80
Voltage of total clearing I2t test 660
Total clearing I²t @Un AC (A²s) 360
Rated breaking capacity I1 AC (kA) 200000
Weight (gr) 130
Price List €48.02/pc
Quantity

Fuse 400V NH1 gG 50A

Reference 2026413.50.0 - Manufacturer SIBA
Class aM
Rated current In (A) 50
Rated Voltage Un AC (V) 400
Dimension NH1
Applicable standards IEC
Power loss (W) 5,1
Melting I²t value (A²s) 6450
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 18000
Rated breaking capacity I1 AC (kA) 120000
Price List €8.80/pc
Quantity

Fuse 400V NH1 gG 63A

Reference 2026413.63.0 - Manufacturer SIBA
Class aM
Rated current In (A) 63
Rated Voltage Un AC (V) 400
Dimension NH1
Applicable standards IEC
Power loss (W) 5,5
Melting I²t value (A²s) 9950
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 32000
Rated breaking capacity I1 AC (kA) 120000
Price List €8.80/pc
Quantity

Fuse 400V NH1 gG 80A

Reference 2026413.80.0 - Manufacturer SIBA
Class aM
Rated current In (A) 80
Rated Voltage Un AC (V) 400
Dimension NH1
Applicable standards IEC
Power loss (W) 6,1
Melting I²t value (A²s) 15500
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 47500
Rated breaking capacity I1 AC (kA) 120000
Price List €8.81/pc
Quantity

Fuse 400V NH2 gG 100A

Reference 2026513.100.0 - Manufacturer SIBA
Class aM
Rated current In (A) 100
Rated Voltage Un AC (V) 400
Dimension NH2
Applicable standards IEC
Power loss (W) 7,4
Melting I²t value (A²s) 24500
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 94000
Rated breaking capacity I1 AC (kA) 120000
Price List €9.30/pc
Quantity

Fuse 400V NH2 gG 125A

Reference 2026513.125.0 - Manufacturer SIBA
Class aM
Rated current In (A) 125
Rated Voltage Un AC (V) 400
Dimension NH2
Applicable standards IEC
Power loss (W) 9,6
Melting I²t value (A²s) 43000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 150000
Rated breaking capacity I1 AC (kA) 120000
Price List €9.31/pc
Quantity

Fuse 400V NH2 gG 160A

Reference 2026513.160.0 - Manufacturer SIBA
Class aM
Rated current In (A) 160
Rated Voltage Un AC (V) 400
Dimension NH2
Applicable standards IEC
Power loss (W) 11,6
Melting I²t value (A²s) 68500
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 250000
Rated breaking capacity I1 AC (kA) 120000
Price List €9.32/pc
Quantity

Fuse 400V NH2 gG 200A

Reference 2026513.200.0 - Manufacturer SIBA
Class aM
Rated current In (A) 200
Rated Voltage Un AC (V) 400
Dimension NH2
Applicable standards IEC
Power loss (W) 13,4
Melting I²t value (A²s) 125000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 425000
Rated breaking capacity I1 AC (kA) 120000
Price List €14.40/pc
Quantity
Filter by
Manufacturer
Series name
Class
Rated Voltage Un AC (V)
Rated Voltage Un DC (V)
Rated insultaion voltage AC (V)
Rated insulated voltage DC (V)
Applicable standards