All Products

Fuse NH2 500V Ty with top indicator and insulated cover 160A

Reference 2044212.160.0 - Manufacturer SIBA
Class Ty
Rated current In (A) 160
Rated Voltage Un AC (V) 500
Dimension NH2
Power loss (W) 16
Melting I²t value (A²s) 62000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 280000
Rated breaking capacity I1 AC (kA) 100000
Product available on request Ask for more information

Fuse NH2 500V Ty with top indicator and insulated cover 200A

Reference 2044212.200.0 - Manufacturer SIBA
Class Ty
Rated current In (A) 200
Rated Voltage Un AC (V) 500
Dimension NH2
Power loss (W) 19
Melting I²t value (A²s) 140000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 560000
Rated breaking capacity I1 AC (kA) 100000
Product available on request Ask for more information

Fuse NH2 500V Ty with top indicator and insulated cover 224A

Reference 2044212.224.0 - Manufacturer SIBA
Class Ty
Rated current In (A) 224
Rated Voltage Un AC (V) 500
Dimension NH2
Power loss (W) 21
Melting I²t value (A²s) 180000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 790000
Rated breaking capacity I1 AC (kA) 100000
Product available on request Ask for more information

Fuse NH2 500V Ty with top indicator and insulated cover 250A

Reference 2044212.250.0 - Manufacturer SIBA
Class Ty
Rated current In (A) 250
Rated Voltage Un AC (V) 500
Dimension NH2
Power loss (W) 24
Melting I²t value (A²s) 220000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 960000
Rated breaking capacity I1 AC (kA) 100000
Product available on request Ask for more information

Fuse NH2 500V Ty with top indicator and insulated cover 315A

Reference 2044212.315.0 - Manufacturer SIBA
Class Ty
Rated current In (A) 315
Rated Voltage Un AC (V) 500
Dimension NH2
Power loss (W) 27
Melting I²t value (A²s) 380000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 1800000
Rated breaking capacity I1 AC (kA) 100000
Product available on request Ask for more information

Fuse NH2 500V Ty with top indicator and insulated cover 355A

Reference 2044212.355.0 - Manufacturer SIBA
Class Ty
Rated current In (A) 355
Rated Voltage Un AC (V) 500
Dimension NH2
Power loss (W) 32
Melting I²t value (A²s) 490000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 2200000
Rated breaking capacity I1 AC (kA) 100000
Product available on request Ask for more information

Fuse NH2 500V Ty with top indicator and insulated cover 63A

Reference 2044212.63.0 - Manufacturer SIBA
Class Ty
Rated current In (A) 63
Rated Voltage Un AC (V) 500
Dimension NH2
Power loss (W) 7,6
Melting I²t value (A²s) 7100
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 31000
Rated breaking capacity I1 AC (kA) 100000
Product available on request Ask for more information

Fuse NH2 500V Ty with top indicator and insulated cover 80A

Reference 2044212.80.0 - Manufacturer SIBA
Class Ty
Rated current In (A) 80
Rated Voltage Un AC (V) 500
Dimension NH2
Power loss (W) 9,1
Melting I²t value (A²s) 12000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 52000
Rated breaking capacity I1 AC (kA) 100000
Product available on request Ask for more information

Fuse NH2 gG 500V insulated cover double indicator 100A

Reference 2044213.100.0 - Manufacturer SIBA
Class gG
Rated current In (A) 100
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC
Power loss (W) 7,8
Melting I²t value (A²s) 28900
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 88600
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 20
Price List €15.78/pc
Quantity

Fuse NH2 gG 500V insulated cover double indicator 125A

Reference 2044213.125.0 - Manufacturer SIBA
Class gG
Rated current In (A) 125
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC
Power loss (W) 10
Melting I²t value (A²s) 44400
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 127500
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 314
Price List €14.92/pc
Quantity

Fuse NH2 gG 500V insulated cover double indicator 160A

Reference 2044213.160.0 - Manufacturer SIBA
Class gG
Rated current In (A) 160
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC
Power loss (W) 12,8
Melting I²t value (A²s) 78500
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 226600
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 320
Price List €14.94/pc
Quantity

Fuse NH2 gG 500V insulated cover double indicator 200A

Reference 2044213.200.0 - Manufacturer SIBA
Class gG
Rated current In (A) 200
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC
Power loss (W) 15.5
Melting I²t value (A²s) 157600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 390900
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 447
Price List €17.72/pc
Quantity

Fuse NH2 gG 500V insulated cover double indicator 224A

Reference 2044213.224.0 - Manufacturer SIBA
Class gG
Rated current In (A) 224
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC
Power loss (W) 16,4
Melting I²t value (A²s) 194800
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 483400
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 457
Price List €20.09/pc
Quantity

Fuse NH2 gG 500V insulated cover double indicator 250A

Reference 2044213.250.0 - Manufacturer SIBA
Class gG
Rated current In (A) 250
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC
Power loss (W) 18
Melting I²t value (A²s) 240800
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 616000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 453
Price List €17.74/pc
Quantity

Fuse NH2 gG 500V insulated cover double indicator 300A

Reference 2044213.300.0 - Manufacturer SIBA
Class gG
Rated current In (A) 300
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 610
Price List €21.95/pc
Quantity

Fuse NH2 gG 500V insulated cover double indicator 315A

Reference 2044213.315.0 - Manufacturer SIBA
Class gG
Rated current In (A) 315
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC
Power loss (W) 23
Melting I²t value (A²s) 513000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 1164000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 630
Price List €21.96/pc
Quantity

Fuse NH2 gG 500V insulated cover double indicator 355A

Reference 2044213.355.0 - Manufacturer SIBA
Class gG
Rated current In (A) 355
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC
Power loss (W) 30
Melting I²t value (A²s) 616000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 1483000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 650
Price List €21.97/pc
Quantity

Fuse NH2 gG 500V insulated cover double indicator 400A

Reference 2044213.400.0 - Manufacturer SIBA
Class gG
Rated current In (A) 400
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC
Power loss (W) 32
Melting I²t value (A²s) 859000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 2008000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 600
Price List €22.08/pc
Quantity

Fuse NH3 gG 500V insulated cover double indicator 400A

Reference 2044313.400.0 - Manufacturer SIBA
Class gG
Rated current In (A) 400
Rated Voltage Un AC (V) 500
Dimension NH3
Applicable standards IEC
Power loss (W) 32
Melting I²t value (A²s) 859000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 2008000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 990
Price List €39.77/pc
Quantity

Fuse NH3 gG 500V insulated cover double indicator 500A

Reference 2044313.500.0 - Manufacturer SIBA
Class gG
Rated current In (A) 500
Rated Voltage Un AC (V) 500
Dimension NH3
Applicable standards IEC
Power loss (W) 38
Melting I²t value (A²s) 1130000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 2800000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 974
Price List €45.28/pc
Quantity

Fuse NH3 gG 500V insulated cover double indicator 630A

Reference 2044313.630.0 - Manufacturer SIBA
Class gG
Rated current In (A) 630
Rated Voltage Un AC (V) 500
Dimension NH3
Applicable standards IEC
Power loss (W) 46
Melting I²t value (A²s) 1950000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 4840000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 973
Price List €49.63/pc
Quantity

Fuse NH00 gG 500V double indicator 100A

Reference 2044513.100.0 - Manufacturer SIBA
Class gG
Rated current In (A) 100
Rated Voltage Un AC (V) 500
Dimension NH00
Applicable standards IEC
Power loss (W) 6,8
Melting I²t value (A²s) 24500
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 94000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 211
Price List €29.65/pc
Quantity

Fuse NH00 gG 500V double indicator 25A

Reference 2044513.25.0 - Manufacturer SIBA
Class gG
Rated current In (A) 25
Rated Voltage Un AC (V) 500
Dimension NH00
Applicable standards IEC
Power loss (W) 2,3
Melting I²t value (A²s) 1400
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 3000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 205
Price List €48.31/pc
Quantity

Fuse NH00 gG 500V double indicator 32A

Reference 2044513.32.0 - Manufacturer SIBA
Class gG
Rated current In (A) 32
Rated Voltage Un AC (V) 500
Dimension NH00
Applicable standards IEC
Power loss (W) 3,1
Melting I²t value (A²s) 2950
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 5800
Rated breaking capacity I1 AC (kA) 120000
Product available on request Ask for more information
Filter by
Manufacturer
Series name
Class
Rated Voltage Un AC (V)
Rated Voltage Un DC (V)
Rated insultaion voltage AC (V)
Rated insulated voltage DC (V)
Applicable standards
Product added to compare.
Product added to wishlist