All Products

Fuse NH2 AC 690V aM 120 kA 100A insulated cover

Reference 2045608.100.0 - Manufacturer SIBA
Class aM
Rated current In (A) 100
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 6,65
Melting I²t value (A²s) 29100
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 110000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 460
Price List €47.65/pc
Quantity

Fuse NH2 AC 690V aM 120 kA 125A insulated cover

Reference 2045608.125.0 - Manufacturer SIBA
Class aM
Rated current In (A) 125
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 8,54
Melting I²t value (A²s) 46700
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 178000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 460
Price List €47.65/pc
Quantity

Fuse NH2 AC 690V aM 120 kA 160A insulated cover

Reference 2045608.160.0 - Manufacturer SIBA
Class aM
Rated current In (A) 160
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 11
Melting I²t value (A²s) 74600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 285000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 460
Price List €47.67/pc
Quantity

Fuse NH2 AC 690V aM 120 kA 200A insulated cover

Reference 2045608.200.0 - Manufacturer SIBA
Class aM
Rated current In (A) 200
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 15
Melting I²t value (A²s) 111000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 420000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 460
Price List €47.68/pc
Quantity

Fuse NH2 AC 690V aM 120 kA 224A insulated cover

Reference 2045608.224.0 - Manufacturer SIBA
Class aM
Rated current In (A) 224
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 16
Melting I²t value (A²s) 132000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 500000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 460
Price List €47.70/pc
Quantity

Fuse NH2 AC 690V aM 120 kA 250A insulated cover

Reference 2045608.250.0 - Manufacturer SIBA
Class aM
Rated current In (A) 250
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 20
Melting I²t value (A²s) 167000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 640000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 460
Price List €48.65/pc
Quantity

Fuse NH2 AC 690V aM 120 kA 315A insulated cover

Reference 2045608.315.0 - Manufacturer SIBA
Class aM
Rated current In (A) 315
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 24
Melting I²t value (A²s) 298000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 1150000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 460
Price List €49.15/pc
Quantity

Fuse NH2 AC 690V aM 120 kA 35A insulated cover

Reference 2045608.35.0 - Manufacturer SIBA
Class aM
Rated current In (A) 35
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 2,29
Melting I²t value (A²s) 2820
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 11000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 460
Product available on request Ask for more information

Fuse NH2 AC 690V aM 120 kA 355A insulated cover

Reference 2045608.355.0 - Manufacturer SIBA
Class aM
Rated current In (A) 355
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 25
Melting I²t value (A²s) 446000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 1700000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 460
Price List €49.17/pc
Quantity

Fuse NH2 AC 690V aM 120 kA 40A insulated cover

Reference 2045608.40.0 - Manufacturer SIBA
Class aM
Rated current In (A) 40
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 2,65
Melting I²t value (A²s) 3680
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 14000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 460
Product available on request Ask for more information

Fuse NH2 AC 690V aM 120 kA 400A insulated cover

Reference 2045608.400.0 - Manufacturer SIBA
Class aM
Rated current In (A) 400
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 27
Melting I²t value (A²s) 623000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 2350000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 460
Product available on request Ask for more information

Fuse NH2 AC 690V aM 120 kA 50A insulated cover

Reference 2045608.50.0 - Manufacturer SIBA
Class aM
Rated current In (A) 50
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 3,04
Melting I²t value (A²s) 7290
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 28000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 460
Product available on request Ask for more information

Fuse NH2 AC 690V aM 120 kA 63A insulated cover

Reference 2045608.63.0 - Manufacturer SIBA
Class aM
Rated current In (A) 63
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 4,14
Melting I²t value (A²s) 10400
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 39000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 460
Product available on request Ask for more information

Fuse NH2 AC 690V aM 120 kA 80A insulated cover

Reference 2045608.80.0 - Manufacturer SIBA
Class aM
Rated current In (A) 80
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 5,28
Melting I²t value (A²s) 17800
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 68000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 460
Price List €47.65/pc
Quantity

Fuse NH2 gG 690V insulated cover double indicator 100A

Reference 2045613.100.0 - Manufacturer SIBA
Class gG
Rated current In (A) 100
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 8,6
Melting I²t value (A²s) 28900
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 75000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 440
Price List €39.14/pc
Quantity

Fuse NH2 gG 690V insulated cover double indicator 125A

Reference 2045613.125.0 - Manufacturer SIBA
Class gG
Rated current In (A) 125
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 11
Melting I²t value (A²s) 44400
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 120000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 450
Price List €41.42/pc
Quantity

Fuse NH2 gG 690V insulated cover double indicator 160A

Reference 2045613.160.0 - Manufacturer SIBA
Class gG
Rated current In (A) 160
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 14
Melting I²t value (A²s) 78500
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 240000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 450
Price List €41.43/pc
Quantity

Fuse NH2 gG 690V insulated cover double indicator 200A

Reference 2045613.200.0 - Manufacturer SIBA
Class gG
Rated current In (A) 200
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 16,5
Melting I²t value (A²s) 157600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 350000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 450
Price List €41.44/pc
Quantity

Fuse NH2 gG 500V double indicator 400A

Reference 2044613.400.0 - Manufacturer SIBA
Class gG
Rated current In (A) 400
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC
Power loss (W) 26
Melting I²t value (A²s) 645000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 2500000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 630
Price List €130.49/pc
Quantity

Fuse 400V NH000 gG insulated cover plate 10A

Reference 2044713.10.0 - Manufacturer SIBA
Class gG
Rated current In (A) 10
Rated Voltage Un AC (V) 400
Dimension NH000
Applicable standards IEC
Power loss (W) 2,4
Melting I²t value (A²s) 240
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 695
Rated breaking capacity I1 AC (kA) 120000
Price List €28.96/pc
Quantity

Fuse 400V NH000 gG insulated cover plate 100A

Reference 2044713.100.0 - Manufacturer SIBA
Class gG
Rated current In (A) 100
Rated Voltage Un AC (V) 400
Dimension NH000
Applicable standards IEC
Power loss (W) 6
Melting I²t value (A²s) 24500
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 94000
Rated breaking capacity I1 AC (kA) 120000
Price List €13.93/pc
Quantity

Fuse 400V NH000 gG insulated cover plate 16A

Reference 2044713.16.0 - Manufacturer SIBA
Class gG
Rated current In (A) 16
Rated Voltage Un AC (V) 400
Dimension NH000
Applicable standards IEC
Power loss (W) 3,5
Melting I²t value (A²s) 410
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 810
Rated breaking capacity I1 AC (kA) 120000
Price List €13.93/pc
Quantity

Fuse 400V NH000 gG insulated cover plate 20A

Reference 2044713.20.0 - Manufacturer SIBA
Class gG
Rated current In (A) 20
Rated Voltage Un AC (V) 400
Dimension NH000
Applicable standards IEC
Power loss (W) 2,2
Melting I²t value (A²s) 690
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 1550
Rated breaking capacity I1 AC (kA) 120000
Price List €13.93/pc
Quantity

Fuse 400V NH000 gG insulated cover plate 25A

Reference 2044713.25.0 - Manufacturer SIBA
Class gG
Rated current In (A) 25
Rated Voltage Un AC (V) 400
Dimension NH000
Applicable standards IEC
Power loss (W) 2,3
Melting I²t value (A²s) 1400
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 3000
Rated breaking capacity I1 AC (kA) 120000
Price List €13.93/pc
Quantity
Filter by
Manufacturer
Series name
Class
Rated Voltage Un AC (V)
Rated Voltage Un DC (V)
Rated insultaion voltage AC (V)
Rated insulated voltage DC (V)
Applicable standards
Product added to compare.
Product added to wishlist