All Products

Fuse 10kV 8x150 2A 7004110.2

Reference 187000.2.0 - Manufacturer SIBA
Class F
Rated current In (A) 2
Rated Voltage Un AC (V) 10000
Voltage drop (mV) 1400
Fuse Dimension (mm) 8x150
Melting I²t value (A²s) 1,5
Fuse Connection/Terminal type Cylindrical
Rated breaking capacity I1 AC (kA) 35
Weight (gr) 16
Price List €34.03/pc
Quantity

Fuse 6,3x32 F 250V glass 0,05A 7005960.0,05

Reference 189000.0,05.0 - Manufacturer SIBA
Class F
Rated current In (A) 0,05
Rated Voltage Un AC (V) 250
Applicable standards IEC
Power loss (W) 0,7
Voltage drop (mV) 9600
Fuse Dimension (mm) 6,3x32
Melting I²t value (A²s) 0,0003
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 250
Rated breaking capacity I1 AC (kA) 35
Weight (gr) 2
Price List €5.12/pc
Quantity

Fuse 6,3x32 F 250V glass 0,063A 7005960.0,063

Reference 189000.0,063.0 - Manufacturer SIBA
Class F
Rated current In (A) 0,063
Rated Voltage Un AC (V) 250
Applicable standards IEC
Power loss (W) 0,5
Voltage drop (mV) 6000
Fuse Dimension (mm) 6,3x32
Melting I²t value (A²s) 0,0005
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 250
Rated breaking capacity I1 AC (kA) 35
Weight (gr) 2
Price List €5.12/pc
Quantity

Fuse 6,3x32 F 250V glass 0,315A 7005960.0,315

Reference 189000.0,315.0 - Manufacturer SIBA
Class F
Rated current In (A) 0,315
Rated Voltage Un AC (V) 250
Applicable standards IEC
Power loss (W) 0,3
Voltage drop (mV) 600
Fuse Dimension (mm) 6,3x32
Melting I²t value (A²s) 0,08
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 250
Rated breaking capacity I1 AC (kA) 35
Weight (gr) 2
Price List €0.26/pc
Quantity

Fuse 6,3x32 F 250V glass 1,25A 7005960.1,25

Reference 189000.1,25.0 - Manufacturer SIBA
Class F
Rated current In (A) 1,25
Rated Voltage Un AC (V) 250
Applicable standards IEC
Power loss (W) 0,6
Voltage drop (mV) 300
Fuse Dimension (mm) 6,3x32
Melting I²t value (A²s) 2
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 250
Rated breaking capacity I1 AC (kA) 35
Weight (gr) 2
Price List €0.26/pc
Quantity

Fuse 6,3x32 F 250V glass 1,6A 7005960.1,6

Reference 189000.1,6.0 - Manufacturer SIBA
Class F
Rated current In (A) 1,6
Rated Voltage Un AC (V) 250
Applicable standards IEC
Power loss (W) 0,7
Voltage drop (mV) 300
Fuse Dimension (mm) 6,3x32
Melting I²t value (A²s) 3,3
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 250
Rated breaking capacity I1 AC (kA) 35
Weight (gr) 2
Price List €0.26/pc
Quantity

Fuse 6,3x32 F 250V glass 10A 7005960.10

Reference 189000.10.0 - Manufacturer SIBA
Class F
Rated current In (A) 10
Rated Voltage Un AC (V) 250
Applicable standards IEC
Power loss (W) 2,3
Voltage drop (mV) 150
Fuse Dimension (mm) 6,3x32
Melting I²t value (A²s) 500
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 250
Rated breaking capacity I1 AC (kA) 100
Weight (gr) 3
Price List €0.28/pc
Quantity

Fuse 6,3x32 F 500V UL ceramic 1,6A 7006563.1,6

Reference 189020.1,6.0 - Manufacturer SIBA
Class F
Rated current In (A) 1,6
Rated Voltage Un AC (V) 500
Applicable standards UL
Power loss (W) 1,4
Voltage drop (mV) 140
Fuse Dimension (mm) 6,3x32
Melting I²t value (A²s) 1,5
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 300
Rated breaking capacity I1 AC (kA) 50000
Weight (gr) 3
Price List €0.88/pc
Quantity

Fuse 6,3x32 F 440V ceramic 25A 7006563.25

Reference 189020.25.0 - Manufacturer SIBA
Class F
Rated current In (A) 25
Rated Voltage Un AC (V) 500
Applicable standards UL
Power loss (W) 11
Voltage drop (mV) 110
Fuse Dimension (mm) 6,3x32
Melting I²t value (A²s) 3100
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 500
Rated breaking capacity I1 AC (kA) 50000
Weight (gr) 3
Price List €0.88/pc
Quantity

Fuse 6,3x32 F 500V ceramic 3A 7006563.3

Reference 189020.3.0 - Manufacturer SIBA
Class F
Rated current In (A) 3
Rated Voltage Un AC (V) 500
Applicable standards IEC
Power loss (W) 2,9
Voltage drop (mV) 280
Fuse Dimension (mm) 6,3x32
Melting I²t value (A²s) 6,6
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 500
Rated breaking capacity I1 AC (kA) 50000
Weight (gr) 3
Price List €0.88/pc
Quantity

Fuse 6,3x32 F 500V UL ceramic 4A 7006563.4

Reference 189020.4.0 - Manufacturer SIBA
Class F
Rated current In (A) 4
Rated Voltage Un AC (V) 500
Applicable standards UL
Power loss (W) 2,6
Voltage drop (mV) 220
Fuse Dimension (mm) 6,3x32
Melting I²t value (A²s) 18
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 500
Rated breaking capacity I1 AC (kA) 50000
Weight (gr) 3
Price List €0.88/pc
Quantity

Fuse 6,3x32 F 500V UL ceramic 5A 7006563.5

Reference 189020.5.0 - Manufacturer SIBA
Class F
Rated current In (A) 5
Rated Voltage Un AC (V) 500
Applicable standards UL
Power loss (W) 2,9
Voltage drop (mV) 190
Fuse Dimension (mm) 6,3x32
Melting I²t value (A²s) 40
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 500
Rated breaking capacity I1 AC (kA) 50000
Weight (gr) 3
Price List €0.88/pc
Quantity

Fuse 6,3x32 F 500V ceramic 7A 7006563.7

Reference 189020.7.0 - Manufacturer SIBA
Class F
Rated current In (A) 7
Rated Voltage Un AC (V) 500
Applicable standards IEC
Power loss (W) 3,8
Voltage drop (mV) 150
Fuse Dimension (mm) 6,3x32
Melting I²t value (A²s) 100
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 500
Rated breaking capacity I1 AC (kA) 50000
Weight (gr) 3
Price List €0.88/pc
Quantity

Fuse 6,3x32 T 250V glass 10A 7005961.10

Reference 189100.10.0 - Manufacturer SIBA
Class T
Rated current In (A) 10
Rated Voltage Un AC (V) 250
Power loss (W) 2,3
Voltage drop (mV) 150
Fuse Dimension (mm) 6,3x32
Melting I²t value (A²s) 630
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 250
Rated breaking capacity I1 AC (kA) 35
Weight (gr) 3
Price List €0.42/pc
Quantity

Fuse 6,3x32 T 250V glass 12,5A 7005961.12,5

Reference 189100.12,5.0 - Manufacturer SIBA
Class T
Rated current In (A) 12,5
Rated Voltage Un AC (V) 250
Power loss (W) 2,8
Voltage drop (mV) 150
Fuse Dimension (mm) 6,3x32
Melting I²t value (A²s) 820
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 250
Rated breaking capacity I1 AC (kA) 35
Weight (gr) 3
Price List €0.42/pc
Quantity

Fuse 6,3x32 T 250V glass 16A 7005961.16

Reference 189100.16.0 - Manufacturer SIBA
Class T
Rated current In (A) 16
Rated Voltage Un AC (V) 250
Power loss (W) 3
Voltage drop (mV) 150
Fuse Dimension (mm) 6,3x32
Melting I²t value (A²s) 1200
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 250
Rated breaking capacity I1 AC (kA) 35
Weight (gr) 3
Price List €0.29/pc
Quantity

Fuse 6,3x32 T 250V glass 2,5A 7005961.2,5

Reference 189100.2,5.0 - Manufacturer SIBA
Class T
Rated current In (A) 2,5
Rated Voltage Un AC (V) 250
Power loss (W) 0,7
Voltage drop (mV) 200
Fuse Dimension (mm) 6,3x32
Melting I²t value (A²s) 24
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 250
Rated breaking capacity I1 AC (kA) 35
Weight (gr) 3
Price List €0.53/pc
Quantity

Fuse 6,3x32 T 250V glass 2A 7005961.2

Reference 189100.2.0 - Manufacturer SIBA
Class T
Rated current In (A) 2
Rated Voltage Un AC (V) 250
Power loss (W) 0,6
Voltage drop (mV) 200
Fuse Dimension (mm) 6,3x32
Melting I²t value (A²s) 16
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 250
Rated breaking capacity I1 AC (kA) 35
Weight (gr) 3
Price List €0.84/pc
Quantity

Fuse 6,3x32 T 250V glass 20A 7005961.20

Reference 189100.20.0 - Manufacturer SIBA
Class T
Rated current In (A) 20
Rated Voltage Un AC (V) 250
Power loss (W) 4
Voltage drop (mV) 150
Fuse Dimension (mm) 6,3x32
Melting I²t value (A²s) 1600
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 250
Rated breaking capacity I1 AC (kA) 35
Weight (gr) 3
Price List €0.65/pc
Quantity

Fuse 6,3x32 T 500V UL ceramic 0,1A 7006565.0,1

Reference 189140.0,1.0 - Manufacturer SIBA
Class T
Rated current In (A) 0,1
Rated Voltage Un AC (V) 500
Applicable standards UL
Power loss (W) 1,3
Voltage drop (mV) 3600
Fuse Dimension (mm) 6,3x32
Melting I²t value (A²s) 0,04
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 500
Rated breaking capacity I1 AC (kA) 1500
Weight (gr) 3
Price List €1.79/pc
Quantity

Fuse 6,3x32 T 500V UL ceramic 0,16A 7006565.0,16

Reference 189140.0,16.0 - Manufacturer SIBA
Class T
Rated current In (A) 0,16
Rated Voltage Un AC (V) 500
Applicable standards UL
Power loss (W) 1,5
Voltage drop (mV) 3000
Fuse Dimension (mm) 6,3x32
Melting I²t value (A²s) 0,1
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 500
Rated breaking capacity I1 AC (kA) 1500
Weight (gr) 3
Price List €1.43/pc
Quantity

Fuse 6,3x32 T 500V UL ceramic 0,25A 7006565.0,25

Reference 189140.0,25.0 - Manufacturer SIBA
Class T
Rated current In (A) 0,25
Rated Voltage Un AC (V) 500
Applicable standards UL
Power loss (W) 1,7
Voltage drop (mV) 2000
Fuse Dimension (mm) 6,3x32
Melting I²t value (A²s) 0,25
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 500
Rated breaking capacity I1 AC (kA) 1500
Weight (gr) 3
Price List €1.43/pc
Quantity

Fuse 6,3x32 T 500V ceramic 0,315A 7006565.0,315

Reference 189140.0,315.0 - Manufacturer SIBA
Class T
Rated current In (A) 0,315
Rated Voltage Un AC (V) 500
Applicable standards UL
Power loss (W) 1,8
Voltage drop (mV) 1800
Fuse Dimension (mm) 6,3x32
Melting I²t value (A²s) 0,45
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 500
Rated breaking capacity I1 AC (kA) 1500
Weight (gr) 3
Price List €1.43/pc
Quantity

Fuse 6,3x32 T 500V UL ceramic 0,4A 7006565.0,4

Reference 189140.0,4.0 - Manufacturer SIBA
Class T
Rated current In (A) 0,4
Rated Voltage Un AC (V) 500
Applicable standards UL
Power loss (W) 2
Voltage drop (mV) 1600
Fuse Dimension (mm) 6,3x32
Melting I²t value (A²s) 0,45
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 500
Rated breaking capacity I1 AC (kA) 1500
Weight (gr) 3
Price List €1.43/pc
Quantity
Filter by
Manufacturer
Series name
Class
Rated Voltage Un AC (V)
Rated Voltage Un DC (V)
Rated insultaion voltage AC (V)
Rated insulated voltage DC (V)
Applicable standards
Product added to compare.
Product added to wishlist