All Products

Fuse 24kV 67x442 back-up oil applications +striker 50A 80N

Reference 3046513.50.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 50
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 108
Rated breaking capacity I1 DC (kA) 63000
Fuse Dimension (mm) 67x442
Melting I²t value (A²s) 5700
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 33000
Weight (gr) 3720
Product available on request Ask for more information

Fuse 24kV 67x442 back-up oil applications +striker 63A 80N

Reference 3046513.63.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 63
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 132
Rated breaking capacity I1 DC (kA) 63000
Fuse Dimension (mm) 67x442
Melting I²t value (A²s) 10700
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 66000
Weight (gr) 3720
Price List €271.20/pc
Quantity

Fuse 36kV 53x442 back-up oil applications +striker 10A 80N

Reference 3046613.10.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 10
Rated Voltage Un AC (V) 36000
Applicable standards IEC
Power loss (W) 78
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 75
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 36000
Total clearing I²t @Un AC (A²s) 560
Rated breaking capacity I1 AC (kA) 40000
Price List €233.06/pc
Quantity

Fuse 36kV 53x442 back-up oil applications +striker 16A 80N

Reference 3046613.16.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 16
Rated Voltage Un AC (V) 36000
Applicable standards IEC
Power loss (W) 74
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 250
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 36000
Total clearing I²t @Un AC (A²s) 3000
Rated breaking capacity I1 AC (kA) 40000
Price List €233.59/pc
Quantity

Fuse 36kV 53x442 back-up oil applications +striker 6,3A 80N

Reference 3046613.6,3.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 6,3
Rated Voltage Un AC (V) 36000
Applicable standards IEC
Power loss (W) 44
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 45
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 36000
Total clearing I²t @Un AC (A²s) 360
Rated breaking capacity I1 AC (kA) 40000
Product available on request Ask for more information

Fuse 13,2kV 85x442 back-up 125A with striker 80N

Reference 3046913.125.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 125
Rated Voltage Un AC (V) 13200
Applicable standards IEC
Power loss (W) 130
Resistance (ohm) 5,6
Fuse Dimension (mm) 85x442
Melting I²t value (A²s) 47000
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 13200
Total clearing I²t @Un AC (A²s) 390000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 5596
Price List €300.48/pc
Quantity

B200 - Fuse 38x73mm 1000VDC aBat Axial 300A

Reference 305.921.98.0.0 - Manufacturer FAULTRAP
Class aBat
Rated current In (A) 300
Applicable standards IEC
Power loss (W) 43
Rated Voltage Un DC (V) 1000
Time costant L/R (ms) 2
Series name B200
Rated breaking capacity I1 DC (kA) 50000
Fuse Dimension (mm) 38x73
Melting I²t value (A²s) 37500
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 1000
Total clearing I²t @Un AC (A²s) 145000
Product available on request Ask for more information

Fuse 40,5kV 254x63,5 back-up BV 0,5A

Reference 3050311.0,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 0,5
Rated Voltage Un AC (V) 40500
Applicable standards IEC
Power loss (W) 7
Fuse Dimension (mm) 254x63,5
Melting I²t value (A²s) 0,225
Fuse Connection/Terminal type Cylindrical
Weight (gr) 1940
Product available on request Ask for more information

Fuse 40,5kV 254x63,5 back-up BV 0,5A

Reference 3050411.0,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 0,5
Rated Voltage Un AC (V) 40500
Applicable standards IEC
Power loss (W) 6,5
Fuse Dimension (mm) 254x63,5
Melting I²t value (A²s) 0,225
Fuse Connection/Terminal type Cylindrical
Weight (gr) 1940
Product available on request Ask for more information

Fuse 40,5kV 254x63,5 back-up BV 1A

Reference 3050411.1.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 1
Rated Voltage Un AC (V) 40500
Applicable standards IEC
Power loss (W) 9,2
Fuse Dimension (mm) 254x63,5
Melting I²t value (A²s) 1,1
Fuse Connection/Terminal type Cylindrical
Weight (gr) 1940
Product available on request Ask for more information

Fuse 15,5kV 63,5x254 screw M12 capacitor protection 10A

Reference 3041726.10.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 10
Rated Voltage Un AC (V) 15500
Applicable standards IEC
Power loss (W) 38
Fuse Dimension (mm) 63,5x254
Fixing dimensions M12
Melting I²t value (A²s) 75
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15500
Total clearing I²t @Un AC (A²s) 500
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2111
Product available on request Ask for more information

Fuse 15,5kV 63,5x254 screw M12 capacitor protection 16A

Reference 3041726.16.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 16
Rated Voltage Un AC (V) 15500
Applicable standards IEC
Power loss (W) 37
Fuse Dimension (mm) 63,5x254
Fixing dimensions M12
Melting I²t value (A²s) 250
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15500
Total clearing I²t @Un AC (A²s) 1800
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2111
Product available on request Ask for more information

Fuse 15,5kV 63,5x254 screw M12 capacitor protection 20A

Reference 3041726.20.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 20
Rated Voltage Un AC (V) 15500
Applicable standards IEC
Power loss (W) 40
Fuse Dimension (mm) 63,5x254
Fixing dimensions M12
Melting I²t value (A²s) 640
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15500
Total clearing I²t @Un AC (A²s) 4300
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2111
Product available on request Ask for more information

Fuse 15,5kV 63,5x254 screw M12 capacitor protection 25A

Reference 3041726.25.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 25
Rated Voltage Un AC (V) 15500
Applicable standards IEC
Power loss (W) 56
Fuse Dimension (mm) 63,5x254
Fixing dimensions M12
Melting I²t value (A²s) 1050
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15500
Total clearing I²t @Un AC (A²s) 6700
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2111
Price List €461.16/pc
Quantity

Fuse 15,5kV 63,5x254 screw M12 capacitor protection 31,5A

Reference 3041726.31,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 31,5
Rated Voltage Un AC (V) 15500
Applicable standards IEC
Power loss (W) 65
Fuse Dimension (mm) 63,5x254
Fixing dimensions M12
Melting I²t value (A²s) 1700
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15500
Total clearing I²t @Un AC (A²s) 10800
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2111
Price List €469.79/pc
Quantity

Fuse 15,5kV 63,5x254 screw M12 capacitor protection 40A

Reference 3041726.40.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 40
Rated Voltage Un AC (V) 15500
Applicable standards IEC
Power loss (W) 84
Fuse Dimension (mm) 63,5x254
Fixing dimensions M12
Melting I²t value (A²s) 2900
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15500
Total clearing I²t @Un AC (A²s) 17100
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2111
Price List €479.60/pc
Quantity

Fuse 15,5kV 63,5x254 screw M12 capacitor protection 6,3A

Reference 3041726.6,3.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 6,3
Rated Voltage Un AC (V) 15500
Applicable standards IEC
Power loss (W) 21
Fuse Dimension (mm) 63,5x254
Fixing dimensions M12
Melting I²t value (A²s) 45
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15500
Total clearing I²t @Un AC (A²s) 330
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2111
Product available on request Ask for more information

Fuse 15,5kV 63,5x359 screw M12 capacitor protection 50A

Reference 3041826.50.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 50
Rated Voltage Un AC (V) 15500
Applicable standards IEC
Power loss (W) 101
Fuse Dimension (mm) 63,5x254
Fixing dimensions M12
Melting I²t value (A²s) 5700
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15500
Total clearing I²t @Un AC (A²s) 29700
Rated breaking capacity I1 AC (kA) 63000
Product available on request Ask for more information

Fuse 15,5kV 63,5x359 screw M12 capacitor protection 63A

Reference 3041826.63.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 63
Rated Voltage Un AC (V) 15500
Applicable standards IEC
Power loss (W) 106
Fuse Dimension (mm) 63,5x254
Fixing dimensions M12
Melting I²t value (A²s) 10700
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15500
Total clearing I²t @Un AC (A²s) 59400
Rated breaking capacity I1 AC (kA) 63000
Product available on request Ask for more information
Filter by
Manufacturer
Series name
Class
Rated Voltage Un AC (V)
Rated Voltage Un DC (V)
Rated insultaion voltage AC (V)
Rated insulated voltage DC (V)
Applicable standards
Product added to compare.
Product added to wishlist