All Products

20PV27 - Fuse 2000VDC gPV 27x85mm inline copper 2AWG 125A

Reference 882.278.42.0.0 - Manufacturer FAULTRAP
Class gPV
Rated current In (A) 125
Applicable standards IEC
Power loss (W) 23.4
Rated Voltage Un DC (V) 2000
Time costant L/R (ms) 1-3
Series name 20PV27
Rated breaking capacity I1 DC (kA) 50
Fuse Dimension (mm) 27x85
Melting I²t value (A²s) 11220
Fuse Connection/Terminal type In-line for copper cable
Product available on request Ask for more information

B050 - Fuse 1000VDC aBat 450A - 118,85mm - Tin Plated

Reference 886.009.48.0.0 - Manufacturer FAULTRAP
Class aBat, aR
Rated current In (A) 450
Applicable standards IEC, UL
Power loss (W) 60
Rated Voltage Un DC (V) 1000
Time costant L/R (ms) 2
Series name B050
Rated breaking capacity I1 DC (kA) 100
Fuse Dimension (mm) 50x141
Melting I²t value (A²s) 62000
Minimum breaking current (A) 4500
Fuse Connection/Terminal type Screw fixing
Fixing connection centres (mm) 118
Total clearing I²t @Un DC (A²s) 162000
Product available on request Ask for more information

B100 - Fuse 1000VDC aBat 700A - 152,7mm - Tin Plated

Reference 886.466.75.0.0 - Manufacturer FAULTRAP
Class aBat
Rated current In (A) 700
Applicable standards IEC, UL
Power loss (W) 128
Rated Voltage Un DC (V) 1000
Time costant L/R (ms) 2
Series name B100
Rated breaking capacity I1 DC (kA) 100000
Fuse Dimension (mm) 63,5x130,5
Melting I²t value (A²s) 143600
Minimum breaking current (A) 7000
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 1000
Total clearing I²t @Un AC (A²s) 431000
Product available on request Ask for more information

T500 - Fuse 500VDC aBat d:38mm axial 80mm 250A

Reference 886.506.55.0.0 - Manufacturer FAULTRAP
Class aBat
Rated current In (A) 250
Applicable standards IEC, UL
Power loss (W) 25
Rated Voltage Un DC (V) 500
Time costant L/R (ms) 2
Series name T500
Rated breaking capacity I1 DC (kA) 100000
Fuse Dimension (mm) 38x80
Melting I²t value (A²s) 15500
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 23000
Product available on request Ask for more information

NR2B - Fuse DIN00 80mm aR 700VDC/690VAC with ind. lug 32A

Reference 886.723.70.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 32
Rated Voltage Un AC (V) 690
Dimension 000
Applicable standards IEC, UL
Power loss (W) 7
Rated Voltage Un DC (V) 700
Time costant L/R (ms) 2
Series name NR2B
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 80
Fuse Connection/Terminal type Screw fixing
Fixing connection centres (mm) 80
Voltage of total clearing I2t test 700
Total clearing I²t @Un AC (A²s) 300
Rated breaking capacity I1 AC (kA) 200000
Product available on request Ask for more information

BP22 -Fuse 22x65mm cylindrical 40A

Reference 889.666.78.0.0 - Manufacturer FAULTRAP
Class gBat, gR
Rated current In (A) 40
Applicable standards IEC, UL
Power loss (W) 6,5
Rated Voltage Un DC (V) 1000
Series name BP22
Rated breaking capacity I1 DC (kA) 100000
Fuse Dimension (mm) 22x65
Fuse Connection/Terminal type Cylindrical
Total clearing I²t @Un AC (A²s) 415
Product available on request Ask for more information
Filter by
Manufacturer
Series name
Class
Rated Voltage Un AC (V)
Rated Voltage Un DC (V)
Rated insultaion voltage AC (V)
Rated insulated voltage DC (V)
Applicable standards
Product added to compare.