Fuses

Fuse BS 000 70mm aR 690V w/o indicator 400A

Reference 2055921.400.0 - Manufacturer SIBA
Class aR
Rated current In (A) 400
Rated Voltage Un AC (V) 690
Dimension 000
Applicable standards IEC, UL
Power loss (W) 70
Melting I²t value (A²s) 32100
Fuse Connection/Terminal type BS
Fixing connection centres (mm) 70
Voltage of total clearing I2t test 660
Total clearing I²t @Un AC (A²s) 106000
Rated breaking capacity I1 AC (kA) 200000
Product available on request Ask for more information

Fuse BS 000 70mm aR 690V w/o indicator 50A

Reference 2055921.50.0 - Manufacturer SIBA
Class aR
Rated current In (A) 50
Rated Voltage Un AC (V) 690
Dimension 000
Applicable standards IEC, UL
Power loss (W) 12
Melting I²t value (A²s) 140
Fuse Connection/Terminal type BS
Fixing connection centres (mm) 70
Voltage of total clearing I2t test 660
Total clearing I²t @Un AC (A²s) 770
Rated breaking capacity I1 AC (kA) 200000
Product available on request Ask for more information

Fuse BS 000 70mm aR 690V w/o indicator 63A

Reference 2055921.63.0 - Manufacturer SIBA
Class aR
Rated current In (A) 63
Rated Voltage Un AC (V) 690
Dimension 000
Applicable standards IEC, UL
Power loss (W) 14
Melting I²t value (A²s) 250
Fuse Connection/Terminal type BS
Fixing connection centres (mm) 70
Voltage of total clearing I2t test 660
Total clearing I²t @Un AC (A²s) 1400
Rated breaking capacity I1 AC (kA) 200000
Product available on request Ask for more information

Fuse BS 000 70mm aR 690V w/o indicator 80A

Reference 2055921.80.0 - Manufacturer SIBA
Class aR
Rated current In (A) 80
Rated Voltage Un AC (V) 690
Dimension 000
Applicable standards IEC, UL
Power loss (W) 18
Melting I²t value (A²s) 470
Fuse Connection/Terminal type BS
Fixing connection centres (mm) 70
Voltage of total clearing I2t test 660
Total clearing I²t @Un AC (A²s) 2600
Rated breaking capacity I1 AC (kA) 200000
Product available on request Ask for more information

Fuse 400V NH2 gG insulated cover plate 100A

Reference 2045113.100.0 - Manufacturer SIBA
Class gG
Rated current In (A) 100
Rated Voltage Un AC (V) 400
Dimension NH2
Applicable standards IEC
Power loss (W) 7,4
Melting I²t value (A²s) 24500
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 94000
Rated breaking capacity I1 AC (kA) 120000
Price List €51.14/pc
Quantity

Fuse 400V NH2 gG insulated cover plate 125A

Reference 2045113.125.0 - Manufacturer SIBA
Class gG
Rated current In (A) 125
Rated Voltage Un AC (V) 400
Dimension NH2
Applicable standards IEC
Power loss (W) 9,6
Melting I²t value (A²s) 43000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 150000
Rated breaking capacity I1 AC (kA) 120000
Price List €51.14/pc
Quantity

Fuse 400V NH2 gG insulated cover plate 16A

Reference 2045113.16.0 - Manufacturer SIBA
Class gG
Rated current In (A) 16
Rated Voltage Un AC (V) 400
Dimension NH2
Applicable standards IEC
Melting I²t value (A²s) 410
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 810
Rated breaking capacity I1 AC (kA) 120000
Product available on request Ask for more information

Fuse 400V NH2 gG insulated cover plate 160A

Reference 2045113.160.0 - Manufacturer SIBA
Class gG
Rated current In (A) 160
Rated Voltage Un AC (V) 400
Dimension NH2
Applicable standards IEC
Power loss (W) 11,6
Melting I²t value (A²s) 68500
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 250000
Rated breaking capacity I1 AC (kA) 120000
Price List €51.14/pc
Quantity

Fuse 400V NH2 gG insulated cover plate 20A

Reference 2045113.20.0 - Manufacturer SIBA
Class gG
Rated current In (A) 20
Rated Voltage Un AC (V) 400
Dimension NH2
Applicable standards IEC
Melting I²t value (A²s) 690
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 1550
Rated breaking capacity I1 AC (kA) 120000
Product available on request Ask for more information

Fuse 400V NH2 gG insulated cover plate 200A

Reference 2045113.200.0 - Manufacturer SIBA
Class gG
Rated current In (A) 200
Rated Voltage Un AC (V) 400
Dimension NH2
Applicable standards IEC
Power loss (W) 9,6
Melting I²t value (A²s) 125000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 425000
Rated breaking capacity I1 AC (kA) 120000
Price List €57.23/pc
Quantity

Fuse 400V NH2 gG insulated cover plate 224A

Reference 2045113.224.0 - Manufacturer SIBA
Class gG
Rated current In (A) 224
Rated Voltage Un AC (V) 400
Dimension NH2
Applicable standards IEC
Power loss (W) 14
Melting I²t value (A²s) 185000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 585000
Rated breaking capacity I1 AC (kA) 120000
Price List €57.23/pc
Quantity

Fuse 400V NH2 gG insulated cover plate 25A

Reference 2045113.25.0 - Manufacturer SIBA
Class gG
Rated current In (A) 25
Rated Voltage Un AC (V) 400
Dimension NH2
Applicable standards IEC
Melting I²t value (A²s) 1400
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 3000
Rated breaking capacity I1 AC (kA) 120000
Price List €51.14/pc
Quantity

Fuse 400V NH2 gG insulated cover plate 250A

Reference 2045113.250.0 - Manufacturer SIBA
Class gG
Rated current In (A) 250
Rated Voltage Un AC (V) 400
Dimension NH2
Applicable standards IEC
Power loss (W) 17
Melting I²t value (A²s) 245000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 785000
Rated breaking capacity I1 AC (kA) 120000
Price List €57.23/pc
Quantity

Fuse 400V NH2 gG insulated cover plate 315A

Reference 2045113.315.0 - Manufacturer SIBA
Class gG
Rated current In (A) 315
Rated Voltage Un AC (V) 400
Dimension NH2
Applicable standards IEC
Power loss (W) 22
Melting I²t value (A²s) 380000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 1350000
Rated breaking capacity I1 AC (kA) 120000
Price List €64.62/pc
Quantity

Fuse 400V NH2 gG insulated cover plate 32A

Reference 2045113.32.0 - Manufacturer SIBA
Class gG
Rated current In (A) 32
Rated Voltage Un AC (V) 400
Dimension NH2
Applicable standards IEC
Melting I²t value (A²s) 2950
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 5800
Rated breaking capacity I1 AC (kA) 120000
Product available on request Ask for more information

Fuse 400V NH2 gG insulated cover plate 35A

Reference 2045113.35.0 - Manufacturer SIBA
Class gG
Rated current In (A) 35
Rated Voltage Un AC (V) 400
Dimension NH2
Applicable standards IEC
Power loss (W) 3,9
Melting I²t value (A²s) 3450
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 7750
Rated breaking capacity I1 AC (kA) 120000
Price List €51.14/pc
Quantity

Fuse 400V NH2 gG insulated cover plate 355A

Reference 2045113.355.0 - Manufacturer SIBA
Class gG
Rated current In (A) 355
Rated Voltage Un AC (V) 400
Dimension NH2
Applicable standards IEC
Power loss (W) 24
Melting I²t value (A²s) 550000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 2100000
Rated breaking capacity I1 AC (kA) 120000
Price List €64.62/pc
Quantity

Fuse 400V NH2 gG insulated cover plate 40A

Reference 2045113.40.0 - Manufacturer SIBA
Class gG
Rated current In (A) 40
Rated Voltage Un AC (V) 400
Dimension NH2
Applicable standards IEC
Power loss (W) 4,3
Melting I²t value (A²s) 5600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 11500
Rated breaking capacity I1 AC (kA) 120000
Price List €51.13/pc
Quantity

Fuse 400V NH2 gG insulated cover plate 400A

Reference 2045113.400.0 - Manufacturer SIBA
Class gG
Rated current In (A) 400
Rated Voltage Un AC (V) 400
Dimension NH2
Applicable standards IEC
Power loss (W) 28
Melting I²t value (A²s) 645000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 2250000
Rated breaking capacity I1 AC (kA) 120000
Price List €64.62/pc
Quantity

Fuse 400V NH2 gG insulated cover plate 50A

Reference 2045113.50.0 - Manufacturer SIBA
Class gG
Rated current In (A) 50
Rated Voltage Un AC (V) 400
Dimension NH2
Applicable standards IEC
Power loss (W) 5,1
Melting I²t value (A²s) 6450
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 18000
Rated breaking capacity I1 AC (kA) 120000
Price List €51.14/pc
Quantity

Fuse 400V NH2 gG insulated cover plate 63A

Reference 2045113.63.0 - Manufacturer SIBA
Class gG
Rated current In (A) 63
Rated Voltage Un AC (V) 400
Dimension NH2
Applicable standards IEC
Power loss (W) 5,5
Melting I²t value (A²s) 9950
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 32000
Rated breaking capacity I1 AC (kA) 120000
Price List €51.14/pc
Quantity

Fuse 400V NH2 gG insulated cover plate 80A

Reference 2045113.80.0 - Manufacturer SIBA
Class gG
Rated current In (A) 80
Rated Voltage Un AC (V) 400
Dimension NH2
Applicable standards IEC
Power loss (W) 6,7
Melting I²t value (A²s) 15500
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 47500
Rated breaking capacity I1 AC (kA) 120000
Price List €51.14/pc
Quantity

Fuse NH00 AC 690 V aM 120 kA 125A insulated cover

Reference 2045308.125.0 - Manufacturer SIBA
Class aM
Rated current In (A) 125
Rated Voltage Un AC (V) 690
Dimension NH00
Applicable standards IEC
Power loss (W) 6,6
Melting I²t value (A²s) 46700
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 178000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 130
Product available on request Ask for more information

Fuse NH00 AC 690 V aM 120 kA 160A insulated cover

Reference 2045308.160.0 - Manufacturer SIBA
Class aM
Rated current In (A) 160
Rated Voltage Un AC (V) 690
Dimension NH00
Applicable standards IEC
Power loss (W) 9
Melting I²t value (A²s) 74600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 285000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 130
Product available on request Ask for more information
Filter by
Manufacturer
Series name
Fuse size
Class
Fuse Connection/Terminal type
Rated current In (A)
Rated Voltage Un AC (V)
Rated Voltage Un DC (V)
Applicable standards
Product added to compare.
Product added to wishlist