List of products by manufacturer DF

Fuse NH2 aM 690V with striker 160A

Reference 398345.0.0 - Manufacturer DF
Class aM
Rated current In (A) 160
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 9,9
Melting I²t value (A²s) 82000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 244255
Rated breaking capacity I1 AC (kA) 80000
Weight (gr) 635
Price List €31.07/pc
Quantity

Fuse NH2 aM 690V with striker 200A

Reference 398350.0.0 - Manufacturer DF
Class aM
Rated current In (A) 200
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 13,7
Melting I²t value (A²s) 167000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 497447
Rated breaking capacity I1 AC (kA) 80000
Weight (gr) 635
Price List €31.33/pc
Quantity

Fuse NH2 aM 690V with striker 250A

Reference 398360.0.0 - Manufacturer DF
Class aM
Rated current In (A) 250
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 16,5
Melting I²t value (A²s) 291000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 866809
Rated breaking capacity I1 AC (kA) 80000
Weight (gr) 635
Price List €33.70/pc
Quantity

Fuse NH4 aM 690V with striker 400A

Reference 398510.0.0 - Manufacturer DF
Class aM
Rated current In (A) 400
Rated Voltage Un AC (V) 690
Dimension NH4
Applicable standards IEC
Power loss (W) 23,5
Melting I²t value (A²s) 502000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 1882500
Rated breaking capacity I1 AC (kA) 80000
Weight (gr) 2090
Price List €138.72/pc
Quantity

Fuse NH0S aM 690V with striker 50A

Reference 398150.0.0 - Manufacturer DF
Class aM
Rated current In (A) 50
Rated Voltage Un AC (V) 690
Dimension NH0S
Applicable standards IEC
Melting I²t value (A²s) 9000
Fuse Connection/Terminal type NH knife
Total clearing I²t @Un AC (A²s) 32130
Rated breaking capacity I1 AC (kA) 80000
Weight (gr) 325
Price List €17.37/pc
Quantity

Fuse NH4 aM 690V with striker 800A

Reference 398525.0.0 - Manufacturer DF
Class aM
Rated current In (A) 800
Rated Voltage Un AC (V) 690
Dimension NH4
Applicable standards IEC
Power loss (W) 52
Melting I²t value (A²s) 1880000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 6400000
Rated breaking capacity I1 AC (kA) 80000
Weight (gr) 2090
Price List €142.90/pc
Quantity

Fuse NH4 aM 690V with striker 630A

Reference 398520.0.0 - Manufacturer DF
Class aM
Rated current In (A) 630
Rated Voltage Un AC (V) 690
Dimension NH4
Applicable standards IEC
Power loss (W) 49
Melting I²t value (A²s) 1423000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 5336250
Rated breaking capacity I1 AC (kA) 80000
Weight (gr) 2090
Price List €140.76/pc
Quantity

Fuse NH4 aM 690V with striker 500A

Reference 398515.0.0 - Manufacturer DF
Class aM
Rated current In (A) 500
Rated Voltage Un AC (V) 690
Dimension NH4
Applicable standards IEC
Power loss (W) 34
Melting I²t value (A²s) 760000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 2850000
Rated breaking capacity I1 AC (kA) 80000
Weight (gr) 2090
Price List €139.88/pc
Quantity

Fuse NH3 aM 690V with striker 425A

Reference 398460.0.0 - Manufacturer DF
Class aM
Rated current In (A) 425
Rated Voltage Un AC (V) 690
Dimension NH3
Applicable standards IEC
Power loss (W) 28,5
Melting I²t value (A²s) 582000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 2182500
Rated breaking capacity I1 AC (kA) 80000
Weight (gr) 1060
Price List €48.94/pc
Quantity

Fuse NH2 aM 690V with striker 355A

Reference 398375.0.0 - Manufacturer DF
Class aM
Rated current In (A) 355
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 27,3
Melting I²t value (A²s) 470000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 1400000
Rated breaking capacity I1 AC (kA) 80000
Weight (gr) 635
Price List €36.38/pc
Quantity

Fuse NH3 aM 690V with striker 400A

Reference 398455.0.0 - Manufacturer DF
Class aM
Rated current In (A) 400
Rated Voltage Un AC (V) 690
Dimension NH3
Applicable standards IEC
Power loss (W) 25.5
Melting I²t value (A²s) 502000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 1882500
Rated breaking capacity I1 AC (kA) 80000
Weight (gr) 1060
Price List €48.68/pc
Quantity

Fuse NH0S aM 690V with striker 160A

Reference 398175.0.0 - Manufacturer DF
Class aM
Rated current In (A) 160
Rated Voltage Un AC (V) 690
Dimension NH0S
Applicable standards IEC
Melting I²t value (A²s) 82000
Fuse Connection/Terminal type NH knife
Total clearing I²t @Un AC (A²s) 244255
Rated breaking capacity I1 AC (kA) 80000
Weight (gr) 325
Price List €19.02/pc
Quantity
Product added to compare.
Product added to wishlist