List of products by manufacturer NIKDIM

Fuse NH2 400V gG 800A

Reference 3104801.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 800
Rated Voltage Un AC (V) 400
Dimension NH4a
Power loss (W) 68
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 1950
Product available on request Ask for more information

Fuse NH2 400V gG 631A

Reference 3104631.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 630
Rated Voltage Un AC (V) 400
Dimension NH4a
Power loss (W) 44,4
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 1950
Product available on request Ask for more information

Fuse NH2 400V gG 1250A

Reference 3104126.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 1250
Rated Voltage Un AC (V) 400
Dimension NH4a
Power loss (W) 100,5
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 1950
Product available on request Ask for more information

Fuse NH2 400V gG 1000A

Reference 3104101.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 1000
Rated Voltage Un AC (V) 400
Dimension NH4a
Power loss (W) 72
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 1950
Product available on request Ask for more information

Fuse NH2 400V gG 400A

Reference 3103C400.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 400
Rated Voltage Un AC (V) 400
Dimension NH3C
Applicable standards IEC
Power loss (W) 25,6
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 655
Product available on request Ask for more information

Fuse NH2 400V gG 355A

Reference 3103C355.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 355
Rated Voltage Un AC (V) 400
Dimension NH3C
Applicable standards IEC
Power loss (W) 25
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 655
Product available on request Ask for more information

Fuse NH2 400V gG 315A

Reference 3103C315.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 315
Rated Voltage Un AC (V) 400
Dimension NH3C
Applicable standards IEC
Power loss (W) 23,9
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 655
Product available on request Ask for more information

Fuse NH2 400V gG 315A

Reference 3103315.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 315
Rated Voltage Un AC (V) 400
Dimension NH3
Applicable standards IEC
Power loss (W) 23,9
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 970
Product available on request Ask for more information
Product added to compare.
Product added to wishlist