List of products by manufacturer NIKDIM

Fuse NH2 690V gG 300A

Reference 3002300.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 300
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 22
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 585
Product available on request Ask for more information

Fuse NH2 690V gG 315A

Reference 3002315.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 315
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 25
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 585
Product available on request Ask for more information

Fuse NH2 690V gG 355A

Reference 3002355.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 355
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 27,5
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 585
Product available on request Ask for more information

Fuse NH2 690V gG 400A

Reference 3002400.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 400
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 30
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 585
Product available on request Ask for more information

Fuse NH2C 690V gG 35A

Reference 3002C035.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 35
Rated Voltage Un AC (V) 690
Dimension NH2C
Applicable standards IEC
Power loss (W) 3,9
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 410
Product available on request Ask for more information

Fuse NH2C 690V gG 50A

Reference 3002C050.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 50
Rated Voltage Un AC (V) 690
Dimension NH2C
Applicable standards IEC
Power loss (W) 5,9
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 410
Product available on request Ask for more information

Fuse NH2C 690V gG 63A

Reference 3002C063.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 63
Rated Voltage Un AC (V) 690
Dimension NH2C
Applicable standards IEC
Power loss (W) 5,9
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 410
Product available on request Ask for more information

Fuse NH2C 690V gG 80A

Reference 3002C080.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 80
Rated Voltage Un AC (V) 690
Dimension NH2C
Applicable standards IEC
Power loss (W) 6,7
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 410
Product available on request Ask for more information

Fuse NH2C 690V gG 100A

Reference 3002C100.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 100
Rated Voltage Un AC (V) 690
Dimension NH2C
Applicable standards IEC
Power loss (W) 8.2
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 410
Product available on request Ask for more information

Fuse NH2C 690V gG 125A

Reference 3002C125.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 125
Rated Voltage Un AC (V) 690
Dimension NH2C
Applicable standards IEC
Power loss (W) 9,3
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 410
Product available on request Ask for more information

Fuse NH2C 690V gG 160A

Reference 3002C160.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 160
Rated Voltage Un AC (V) 690
Dimension NH2C
Applicable standards IEC
Power loss (W) 12.5
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 410
Product available on request Ask for more information

Fuse NH2C 690V gG 200A

Reference 3002C200.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 200
Rated Voltage Un AC (V) 690
Dimension NH2C
Applicable standards IEC
Power loss (W) 15,9
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 410
Product available on request Ask for more information

Fuse NH2C 690V gG 224A

Reference 3002C224.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 224
Rated Voltage Un AC (V) 690
Dimension NH2C
Applicable standards IEC
Power loss (W) 18,4
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 410
Product available on request Ask for more information

Fuse NH2C 690V gG 250A

Reference 3002C250.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 250
Rated Voltage Un AC (V) 690
Dimension NH2C
Applicable standards IEC
Power loss (W) 20,4
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 410
Product available on request Ask for more information

Fuse NH1 690V gG 16A

Reference 3001016.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 16
Rated Voltage Un AC (V) 690
Dimension NH1
Applicable standards IEC
Power loss (W) 3,3
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 380
Product available on request Ask for more information

Fuse NH1 690V gG 20A

Reference 3001020.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 20
Rated Voltage Un AC (V) 690
Dimension NH1
Applicable standards IEC
Power loss (W) 3,6
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 380
Product available on request Ask for more information

Fuse NH1 690V gG 25A

Reference 3001025.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 25
Rated Voltage Un AC (V) 690
Dimension NH1
Applicable standards IEC
Power loss (W) 3,7
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 380
Product available on request Ask for more information

Fuse NH1 690V gG 35A

Reference 3001035.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 35
Rated Voltage Un AC (V) 690
Dimension NH1
Applicable standards IEC
Power loss (W) 4,1
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 380
Product available on request Ask for more information

Fuse NH1 690V gG 40A

Reference 3001040.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 40
Rated Voltage Un AC (V) 690
Dimension NH1
Applicable standards IEC
Power loss (W) 4,4
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 380
Product available on request Ask for more information

Fuse NH1 690V gG 50A

Reference 3001050.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 50
Rated Voltage Un AC (V) 690
Dimension NH1
Applicable standards IEC
Power loss (W) 4,5
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 380
Product available on request Ask for more information

Fuse NH1 690V gG 63A

Reference 3001063.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 63
Rated Voltage Un AC (V) 690
Dimension NH1
Applicable standards IEC
Power loss (W) 6,1
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 380
Product available on request Ask for more information

Fuse NH1 690V gG 80A

Reference 3001080.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 80
Rated Voltage Un AC (V) 690
Dimension NH1
Applicable standards IEC
Power loss (W) 6,9
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 380
Product available on request Ask for more information

Fuse NH1 690V gG 100A

Reference 3001100.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 100
Rated Voltage Un AC (V) 690
Dimension NH1
Applicable standards IEC
Power loss (W) 8.5
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 380
Product available on request Ask for more information

Fuse NH1 690V gG 125A

Reference 3001125.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 125
Rated Voltage Un AC (V) 690
Dimension NH1
Applicable standards IEC
Power loss (W) 9,6
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 380
Product available on request Ask for more information

Fuse NH1 690V gG 160A

Reference 3001160.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 160
Rated Voltage Un AC (V) 690
Dimension NH1
Applicable standards IEC
Power loss (W) 11,8
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 380
Product available on request Ask for more information

Fuse NH1 690V gG 200A

Reference 3001200.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 200
Rated Voltage Un AC (V) 690
Dimension NH1
Applicable standards IEC
Power loss (W) 13,9
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 380
Product available on request Ask for more information

Fuse NH1 690V gG 224A

Reference 3001224.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 224
Rated Voltage Un AC (V) 690
Dimension NH1
Applicable standards IEC
Power loss (W) 14,4
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 380
Product available on request Ask for more information

Fuse NH1 690V gG 250A

Reference 3001250.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 250
Rated Voltage Un AC (V) 690
Dimension NH1
Applicable standards IEC
Power loss (W) 15
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 380
Product available on request Ask for more information

Fuse NH1C 690V gG 16A

Reference 3001C016.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 16
Rated Voltage Un AC (V) 690
Dimension NH1C
Applicable standards IEC
Power loss (W) 3,3
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 270
Product available on request Ask for more information

Fuse NH1C 690V gG 20A

Reference 3001C020.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 20
Rated Voltage Un AC (V) 690
Dimension NH1C
Applicable standards IEC
Power loss (W) 3,6
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 270
Product available on request Ask for more information

Fuse NH1C 690V gG 25A

Reference 3001C025.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 25
Rated Voltage Un AC (V) 690
Dimension NH1C
Applicable standards IEC
Power loss (W) 3,7
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 270
Product available on request Ask for more information

Fuse NH1C 690V gG 35A

Reference 3001C035.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 35
Rated Voltage Un AC (V) 690
Dimension NH1C
Applicable standards IEC
Power loss (W) 4,1
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 270
Product available on request Ask for more information
Product added to compare.
Product added to wishlist