List of products by manufacturer SIBA

Fuse 12kV 67x537 back-up with striker 80A 80N

Reference 3034513.80.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 80
Rated Voltage Un AC (V) 6000
Applicable standards IEC
Power loss (W) 73
Resistance (ohm) 0,0083
Fuse Dimension (mm) 63x537
Melting I²t value (A²s) 17500
Minimum breaking current (A) 280
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 5220
Total clearing I²t @Un AC (A²s) 240000
Rated breaking capacity I1 AC (kA) 63000
Price List €341.43/pc
Quantity

Fuse 36kV 63,5x440 M8/M8 oiltight 40A

Reference 3032411.40.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 40
Rated Voltage Un AC (V) 36000
Applicable standards IEC
Power loss (W) 155
Fuse Dimension (mm) 63,5x440
Melting I²t value (A²s) 2640
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 36000
Total clearing I²t @Un AC (A²s) 31700
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 3633
Price List €1,203.00/pc
Quantity

Fuse 24kV 63,5x360 general purpose with striker 10A 50N

Reference 3031296.10.0 - Manufacturer SIBA
Class HH G P
Rated current In (A) 10
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 21
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 250
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 3200
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2540
Product available on request Ask for more information

Fuse 24kV 63,5x360 general purpose with striker 12A 50N

Reference 3031296.12.0 - Manufacturer SIBA
Class HH G P
Rated current In (A) 12
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 24
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 460
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 5000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2540
Price List €1,097.95/pc
Quantity

Fuse 24kV 63,5x360 general purpose with striker 16A 50N

Reference 3031296.16.0 - Manufacturer SIBA
Class HH G P
Rated current In (A) 16
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 31
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 830
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 8300
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2540
Price List €1,099.15/pc
Quantity

Fuse 24kV 63,5x360 general purpose with striker 20A 50N

Reference 3031296.20.0 - Manufacturer SIBA
Class HH G P
Rated current In (A) 20
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 21
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 1730
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 17300
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2540
Price List €1,101.72/pc
Quantity

Fuse 24kV 63,5x360 general purpose with striker 6,3A 50N

Reference 3031296.6,3.0 - Manufacturer SIBA
Class HH G P
Rated current In (A) 6,3
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 13
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 110
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 1200
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2540
Product available on request Ask for more information

Fuse 24kV 63,5x360 general purpose with striker 8A 50N

Reference 3031296.8.0 - Manufacturer SIBA
Class HH G P
Rated current In (A) 8
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 17
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 172
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 1900
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2540
Product available on request Ask for more information

Fuse 24kV 63,5x440 general purpose without striker 25A

Reference 3031391.25.0 - Manufacturer SIBA
Class HH G P
Rated current In (A) 25
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 40
Fuse Dimension (mm) 63,5x440
Melting I²t value (A²s) 1150
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 10500
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2540
Product available on request Ask for more information

Fuse 24kV 63,5x440 general purpose without striker 31,5A

Reference 3031391.31,5.0 - Manufacturer SIBA
Class HH G P
Rated current In (A) 31,5
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 55
Fuse Dimension (mm) 63,5x440
Melting I²t value (A²s) 2100
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 16500
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2540
Product available on request Ask for more information

Fuse 24kV 63,5x440 general purpose without striker 40A

Reference 3031391.40.0 - Manufacturer SIBA
Class HH G P
Rated current In (A) 40
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 71
Fuse Dimension (mm) 63,5x440
Melting I²t value (A²s) 2850
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 19500
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2540
Product available on request Ask for more information

Fuse 24kV 63,5x440 general purpose with striker 25A 50N

Reference 3031396.25.0 - Manufacturer SIBA
Class HH G P
Rated current In (A) 25
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 40
Fuse Dimension (mm) 63,5x440
Melting I²t value (A²s) 1150
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 10500
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2000
Price List €1,303.74/pc
Quantity

Fuse 24kV 63,5x440 general purpose with striker 31,5A 50N

Reference 3031396.31,5.0 - Manufacturer SIBA
Class HH G P
Rated current In (A) 31,5
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 55
Fuse Dimension (mm) 63,5x440
Melting I²t value (A²s) 2100
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 16500
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2000
Product available on request Ask for more information

Fuse 24kV 63,5x440 general purpose with striker 40A 50N

Reference 3031396.40.0 - Manufacturer SIBA
Class HH G P
Rated current In (A) 40
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 71
Fuse Dimension (mm) 63,5x440
Melting I²t value (A²s) 2850
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 19500
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2000
Price List €1,308.57/pc
Quantity

Fuse 24kV 63,5x293mm general purpose without striker 10A

Reference 3031591.10.0 - Manufacturer SIBA
Class HH G P
Rated current In (A) 10
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 22
Fuse Dimension (mm) 63,5x293
Melting I²t value (A²s) 250
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 3200
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2800
Product available on request Ask for more information

Fuse 24kV 63,5x293mm general purpose without striker 8A

Reference 3031591.8.0 - Manufacturer SIBA
Class HH G P
Rated current In (A) 8
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 18
Fuse Dimension (mm) 63,5x293
Melting I²t value (A²s) 172
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 1900
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2800
Price List €765.44/pc
Quantity

Fuse 24kV 63,5x293mm general purpose without striker 10A

Reference 3031596.10.0 - Manufacturer SIBA
Class HH G P
Rated current In (A) 10
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 22
Fuse Dimension (mm) 63,5x293
Melting I²t value (A²s) 250
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 3200
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2160
Price List €1,043.56/pc
Quantity

Fuse 24kV 63,5x293mm general purpose without striker 8A

Reference 3031596.8.0 - Manufacturer SIBA
Class HH G P
Rated current In (A) 8
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 18
Fuse Dimension (mm) 63,5x293
Melting I²t value (A²s) 172
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 1900
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2160
Price List €888.93/pc
Quantity

Fuse 36kV 63,5x360 M8/M8 oiltight 10A

Reference 3032311.10.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 10
Rated Voltage Un AC (V) 36000
Applicable standards IEC
Power loss (W) 85
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 70
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 36000
Total clearing I²t @Un AC (A²s) 1100
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 2580
Price List €180.76/pc
Quantity

Fuse 36kV 63,5x360 M8/M8 oiltight 16A

Reference 3032311.16.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 16
Rated Voltage Un AC (V) 36000
Applicable standards IEC
Power loss (W) 50
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 160
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 36000
Total clearing I²t @Un AC (A²s) 1900
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 2580
Price List €1,032.46/pc
Quantity

Fuse 36kV 63,5x360 M8/M8 oiltight 20A

Reference 3032311.20.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 20
Rated Voltage Un AC (V) 36000
Applicable standards IEC
Power loss (W) 73
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 550
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 36000
Total clearing I²t @Un AC (A²s) 6600
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 2580
Price List €1,036.34/pc
Quantity

Fuse 36kV 63,5x360 M8/M8 oiltight 25A

Reference 3032311.25.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 25
Rated Voltage Un AC (V) 36000
Applicable standards IEC
Power loss (W) 88
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 920
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 36000
Total clearing I²t @Un AC (A²s) 11000
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 2580
Price List €216.74/pc
Quantity

Fuse 36kV 63,5x360 M8/M8 oiltight 3,15A

Reference 3032311.3,15.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 3,15
Rated Voltage Un AC (V) 36000
Applicable standards IEC
Power loss (W) 26
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 14
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 36000
Total clearing I²t @Un AC (A²s) 91
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 2677
Price List €187.09/pc
Quantity

Fuse 36kV 63,5x360 M8/M8 oiltight 4A

Reference 3032311.4.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 4
Rated Voltage Un AC (V) 36000
Applicable standards IEC
Power loss (W) 33
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 29
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 36000
Total clearing I²t @Un AC (A²s) 190
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 2677
Product available on request Ask for more information

Fuse 36kV 63,5x360 M8/M8 oiltight 5A

Reference 3032311.5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 5
Rated Voltage Un AC (V) 36000
Applicable standards IEC
Power loss (W) 40
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 44
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 36000
Total clearing I²t @Un AC (A²s) 285
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 2500
Price List €186.98/pc
Quantity

Fuse 36kV 63,5x360 M8/M8 oiltight 6,3A

Reference 3032311.6,3.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 6,3
Rated Voltage Un AC (V) 36000
Applicable standards IEC
Power loss (W) 49
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 45
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 36000
Total clearing I²t @Un AC (A²s) 360
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 2580
Price List €190.68/pc
Quantity

Fuse 36kV 63,5x360 M8/G1/8 oiltight with striker 10A 50N

Reference 3032316.10.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 10
Rated Voltage Un AC (V) 36000
Applicable standards IEC
Power loss (W) 85
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 70
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 36000
Total clearing I²t @Un AC (A²s) 1100
Rated breaking capacity I1 AC (kA) 40000
Product available on request Ask for more information

Fuse 36kV 63,5x360 M8/G1/8 oiltight with striker 16A 50N

Reference 3032316.16.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 16
Rated Voltage Un AC (V) 36000
Applicable standards IEC
Power loss (W) 50
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 160
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 36000
Total clearing I²t @Un AC (A²s) 1900
Rated breaking capacity I1 AC (kA) 40000
Product available on request Ask for more information

Fuse 36kV 63,5x360 M8/G1/8 oiltight with striker 20A 50N

Reference 3032316.20.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 20
Rated Voltage Un AC (V) 36000
Applicable standards IEC
Power loss (W) 73
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 550
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 36000
Total clearing I²t @Un AC (A²s) 6600
Rated breaking capacity I1 AC (kA) 40000
Product available on request Ask for more information

Fuse 36kV 63,5x360 M8/G1/8 oiltight with striker 25A 50N

Reference 3032316.25.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 25
Rated Voltage Un AC (V) 36000
Applicable standards IEC
Power loss (W) 88
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 920
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 36000
Total clearing I²t @Un AC (A²s) 11000
Rated breaking capacity I1 AC (kA) 40000
Product available on request Ask for more information

Fuse 36kV 63,5x360 M8/G1/8 oiltight with striker 3,15A 50N

Reference 3032316.3,15.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 3,15
Rated Voltage Un AC (V) 36000
Applicable standards IEC
Power loss (W) 26
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 14
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 36000
Total clearing I²t @Un AC (A²s) 91
Rated breaking capacity I1 AC (kA) 40000
Product available on request Ask for more information

Fuse 36kV 63,5x360 M8/G1/8 oiltight with striker 4A 50N

Reference 3032316.4.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 4
Rated Voltage Un AC (V) 36000
Applicable standards IEC
Power loss (W) 33
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 29
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 36000
Total clearing I²t @Un AC (A²s) 190
Rated breaking capacity I1 AC (kA) 40000
Product available on request Ask for more information

Fuse 36kV 63,5x360 M8/G1/8 oiltight with striker 5A 50N

Reference 3032316.5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 5
Rated Voltage Un AC (V) 36000
Applicable standards IEC
Power loss (W) 40
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 44
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 3600
Total clearing I²t @Un AC (A²s) 285
Rated breaking capacity I1 AC (kA) 40000
Product available on request Ask for more information

Fuse 38,5kV TV DIN 53x537 without striker 5A

Reference 3033711.5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 5
Rated Voltage Un AC (V) 38500
Applicable standards IEC
Power loss (W) 26
Resistance (ohm) 0,748
Fuse Dimension (mm) 53x537
Melting I²t value (A²s) 40
Minimum breaking current (A) 40
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 33495
Total clearing I²t @Un AC (A²s) 125
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 2760
Product available on request Ask for more information

Fuse 38,5kV TV DIN 53x537 without striker 4A

Reference 3033711.4.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 4
Rated Voltage Un AC (V) 38500
Applicable standards IEC
Power loss (W) 38
Resistance (ohm) 1,64
Fuse Dimension (mm) 53x537
Melting I²t value (A²s) 31
Minimum breaking current (A) 32
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 33495
Total clearing I²t @Un AC (A²s) 90
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 2760
Product available on request Ask for more information

Fuse 38,5kV TV DIN 53x537 without striker 3,15A

Reference 3033711.3,15.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 3,15
Rated Voltage Un AC (V) 38500
Applicable standards IEC
Power loss (W) 29
Resistance (ohm) 2,2
Fuse Dimension (mm) 53x537
Melting I²t value (A²s) 17
Minimum breaking current (A) 24
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 33495
Total clearing I²t @Un AC (A²s) 48
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 2760
Product available on request Ask for more information