List of products by manufacturer SIBA

Fuse SQB2 gR 1800/2000VDC with indicator 250A

Reference 9020121.250.0 - Manufacturer SIBA
Class gR
Rated current In (A) 250
Dimension SQB2
Applicable standards IEC
Power loss (W) 124
Rated Voltage Un DC (V) 1800
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 16000
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 2000
Total clearing I²t @Un AC (A²s) 87300
Weight (gr) 2367
Price List €465.92/pc
Quantity

Fuse SQB2 gR 1800/2000VDC without indicator 250A

Reference 9020120.250.0 - Manufacturer SIBA
Class gR
Rated current In (A) 250
Dimension SQB2
Applicable standards IEC
Power loss (W) 124
Rated Voltage Un DC (V) 1800
Time costant L/R (ms) 15
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 16000
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 2000
Total clearing I²t @Un AC (A²s) 87300
Weight (gr) 2367
Product available on request Ask for more information

Fuse SQB2 aR 3600V/4200VDC with indicator 160A

Reference 9020026.160.0 - Manufacturer SIBA
Class aR
Rated current In (A) 160
Dimension SQB2
Applicable standards IEC
Power loss (W) 120
Rated Voltage Un DC (V) 3600
Time costant L/R (ms) 15
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 6600
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 4200
Total clearing I²t @Un AC (A²s) 55300
Weight (gr) 3540
Price List €1,223.04/pc
Quantity

Fuse SQB2 aR 3600V/4200VDC without indicator 315A

Reference 9020025.315.0 - Manufacturer SIBA
Class aR
Rated current In (A) 315
Dimension SQB2
Applicable standards IEC
Power loss (W) 220
Rated Voltage Un DC (V) 3600
Time costant L/R (ms) 15
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 33000
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 4200
Total clearing I²t @Un AC (A²s) 273000
Weight (gr) 3900
Price List €1,550.73/pc
Quantity

Fuse SQB2 aR 3600V/4200VDC without indicator 200A

Reference 9020025.200.0 - Manufacturer SIBA
Class aR
Rated current In (A) 200
Dimension SQB2
Applicable standards IEC
Power loss (W) 145
Rated Voltage Un DC (V) 3600
Time costant L/R (ms) 15
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 11800
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 4200
Total clearing I²t @Un AC (A²s) 98000
Weight (gr) 3920
Price List €1,182.06/pc
Quantity

Fuse SQB2 gR 3600V/4000VDC 200A

Reference 9020020.200.0 - Manufacturer SIBA
Class gR
Rated current In (A) 200
Dimension SQB2
Applicable standards IEC
Power loss (W) 143
Rated Voltage Un DC (V) 4000
Time costant L/R (ms) 15
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 4600
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 4000
Total clearing I²t @Un AC (A²s) 38200
Weight (gr) 3880
Product available on request Ask for more information

Fuse railway application 40x254 3000V DC without pin 6,3A

Reference 9010110.6,3.0 - Manufacturer SIBA
Class gR
Rated current In (A) 6,3
Applicable standards IEC
Power loss (W) 22
Rated Voltage Un DC (V) 3600
Time costant L/R (ms) 15
Rated breaking capacity I1 DC (kA) 3200
Fuse Dimension (mm) 39,6x254
Melting I²t value (A²s) 24
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 4000
Total clearing I²t @Un AC (A²s) 41
Weight (gr) 780
Product available on request Ask for more information

Fuse railway application 40x254 3000V DC without pin 3,15A

Reference 9010110.3,15.0 - Manufacturer SIBA
Class gR
Rated current In (A) 3,15
Applicable standards IEC
Power loss (W) 13
Rated Voltage Un DC (V) 3600
Time costant L/R (ms) 15
Rated breaking capacity I1 DC (kA) 3200
Fuse Dimension (mm) 39,6x254
Melting I²t value (A²s) 4
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 4000
Total clearing I²t @Un AC (A²s) 8
Weight (gr) 780
Product available on request Ask for more information

Fuse railway application 39,6x254 gR 4000VDC 6,3A

Reference 9010010.6,3.0 - Manufacturer SIBA
Class gR
Rated current In (A) 6,3
Applicable standards IEC
Power loss (W) 22
Rated Voltage Un DC (V) 3600
Time costant L/R (ms) 15
Rated breaking capacity I1 DC (kA) 3200
Fuse Dimension (mm) 39,6x254
Melting I²t value (A²s) 24
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 4000
Total clearing I²t @Un AC (A²s) 41
Weight (gr) 800
Price List €302.81/pc
Quantity

Fuse railway application 39,6x254 gR 4000VDC 31,5A

Reference 9010010.31,5.0 - Manufacturer SIBA
Class gR
Rated current In (A) 31,5
Applicable standards IEC
Power loss (W) 40
Rated Voltage Un DC (V) 3600
Time costant L/R (ms) 15
Rated breaking capacity I1 DC (kA) 3200
Fuse Dimension (mm) 39,6x254
Melting I²t value (A²s) 410
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 4000
Total clearing I²t @Un AC (A²s) 1300
Weight (gr) 800
Price List €81.82/pc
Quantity

Fuse railway application 39,6x254 gR 4000VDC 3,15A

Reference 9010010.3,15.0 - Manufacturer SIBA
Class gR
Rated current In (A) 3,15
Applicable standards IEC
Power loss (W) 13
Rated Voltage Un DC (V) 3600
Time costant L/R (ms) 15
Rated breaking capacity I1 DC (kA) 3200
Fuse Dimension (mm) 39,6x254
Melting I²t value (A²s) 4
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 4000
Total clearing I²t @Un AC (A²s) 8
Weight (gr) 780
Price List €302.00/pc
Quantity

Fuse railway application 39,6x254 gR 4000VDC 12,5A

Reference 9010010.12,5.0 - Manufacturer SIBA
Class gR
Rated current In (A) 12,5
Applicable standards IEC
Power loss (W) 40
Rated Voltage Un DC (V) 3600
Time costant L/R (ms) 15
Rated breaking capacity I1 DC (kA) 3200
Fuse Dimension (mm) 39,6x254
Melting I²t value (A²s) 68
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 4000
Total clearing I²t @Un AC (A²s) 220
Weight (gr) 780
Price List €304.90/pc
Quantity
Product added to compare.
Product added to wishlist