List of products by manufacturer SIBA

Fuse NH1 gG 500V insulated cover double indicator 63A

Reference 2044113.63.0 - Manufacturer SIBA
Class gG
Rated current In (A) 63
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 5,8
Melting I²t value (A²s) 10300
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 26400
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 290
Price List €10.45/pc
Quantity

Fuse NH1 gG 500V insulated cover double indicator 80A

Reference 2044113.80.0 - Manufacturer SIBA
Class gG
Rated current In (A) 80
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 6,5
Melting I²t value (A²s) 17300
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 45500
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 300
Price List €10.45/pc
Quantity

Fuse NH2 gG 500V insulated cover double indicator 100A

Reference 2044213.100.0 - Manufacturer SIBA
Class gG
Rated current In (A) 100
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC
Power loss (W) 7,8
Melting I²t value (A²s) 28900
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 88600
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 20
Price List €15.78/pc
Quantity

Fuse NH2 gG 500V insulated cover double indicator 125A

Reference 2044213.125.0 - Manufacturer SIBA
Class gG
Rated current In (A) 125
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC
Power loss (W) 10
Melting I²t value (A²s) 44400
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 127500
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 314
Price List €14.92/pc
Quantity

Fuse NH000/NH00C gG 500V insulated cover double ind 80A

Reference 2043813.80.0 - Manufacturer SIBA
Class gG
Rated current In (A) 80
Rated Voltage Un AC (V) 500
Dimension NH00C
Applicable standards IEC
Power loss (W) 5,4
Melting I²t value (A²s) 17300
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 45500
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 124
Price List €6.32/pc
Quantity

Fuse NH000/NH00C gG 500V insulated cover double ind 20A

Reference 2043813.20.0 - Manufacturer SIBA
Class gG
Rated current In (A) 20
Rated Voltage Un AC (V) 500
Dimension NH00C
Applicable standards IEC
Power loss (W) 2,4
Melting I²t value (A²s) 760
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 1480
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 130
Price List €6.25/pc
Quantity

Fuse NH2 gG 500V insulated cover double indicator 250A

Reference 2044213.250.0 - Manufacturer SIBA
Class gG
Rated current In (A) 250
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC
Power loss (W) 18
Melting I²t value (A²s) 240800
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 616000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 453
Price List €17.74/pc
Quantity

Fuse NH000/NH00C gG 500V insulated cover double ind 25A

Reference 2043813.25.0 - Manufacturer SIBA
Class gG
Rated current In (A) 25
Rated Voltage Un AC (V) 500
Dimension NH00C
Applicable standards IEC
Power loss (W) 2,3
Melting I²t value (A²s) 1440
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 2890
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 128
Price List €6.25/pc
Quantity

Fuse NH2 gG 500V insulated cover double indicator 200A

Reference 2044213.200.0 - Manufacturer SIBA
Class gG
Rated current In (A) 200
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC
Power loss (W) 15.5
Melting I²t value (A²s) 157600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 390900
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 447
Price List €17.72/pc
Quantity

Fuse NH2 gG 500V insulated cover double indicator 160A

Reference 2044213.160.0 - Manufacturer SIBA
Class gG
Rated current In (A) 160
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC
Power loss (W) 12,8
Melting I²t value (A²s) 78500
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 226600
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 320
Price List €14.94/pc
Quantity
Product added to compare.
Product added to wishlist