List of products by manufacturer SIBA

Fuse NH000/NH00C AC 690V aM 120 kA 16A insulated cover

Reference 2045208.16.0 - Manufacturer SIBA
Class aM
Rated current In (A) 16
Rated Voltage Un AC (V) 690
Dimension NH00C
Applicable standards IEC
Power loss (W) 0,8
Melting I²t value (A²s) 476
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 1800
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 130
Price List €22.74/pc
Quantity

Fuse NH000/NH00C AC 690V aM 120 kA 10A insulated cover

Reference 2045208.10.0 - Manufacturer SIBA
Class aM
Rated current In (A) 10
Rated Voltage Un AC (V) 690
Dimension NH00C
Applicable standards IEC
Power loss (W) 0,5
Melting I²t value (A²s) 490
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 1900
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 130
Price List €22.74/pc
Quantity

Fuse NH1 gG 500V insulated cover double indicator 100A

Reference 2044113.100.0 - Manufacturer SIBA
Class gG
Rated current In (A) 100
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 7,8
Melting I²t value (A²s) 28900
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 88600
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 280
Price List €12.54/pc
Quantity

Fuse NH1 gG 500V insulated cover double indicator 125A

Reference 2044113.125.0 - Manufacturer SIBA
Class gG
Rated current In (A) 125
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 10
Melting I²t value (A²s) 44400
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 127500
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 297
Price List €12.55/pc
Quantity

Fuse NH1 gG 500V insulated cover double indicator 250A

Reference 2044113.250.0 - Manufacturer SIBA
Class gG
Rated current In (A) 250
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 17,9
Melting I²t value (A²s) 240800
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 616000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 333
Price List €16.55/pc
Quantity

Fuse NH1 gG 500V insulated cover double indicator 63A

Reference 2044113.63.0 - Manufacturer SIBA
Class gG
Rated current In (A) 63
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 5,8
Melting I²t value (A²s) 10300
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 26400
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 290
Price List €10.45/pc
Quantity

Fuse NH1 gG 500V insulated cover double indicator 50A

Reference 2044113.50.0 - Manufacturer SIBA
Class gG
Rated current In (A) 50
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 5,1
Melting I²t value (A²s) 5900
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 13600
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 300
Price List €10.44/pc
Quantity

Fuse NH1 gG 500V insulated cover double indicator 35A

Reference 2044113.35.0 - Manufacturer SIBA
Class gG
Rated current In (A) 35
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 3,9
Melting I²t value (A²s) 3100
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 7610
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 310
Price List €17.23/pc
Quantity

Fuse NH1 gG 500V insulated cover double indicator 200A

Reference 2044113.200.0 - Manufacturer SIBA
Class gG
Rated current In (A) 200
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 15
Melting I²t value (A²s) 157600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 390900
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 420
Price List €14.81/pc
Quantity

Fuse NH1 gG 500V insulated cover double indicator 160A

Reference 2044113.160.0 - Manufacturer SIBA
Class gG
Rated current In (A) 160
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 12,8
Melting I²t value (A²s) 78500
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 226600
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 309
Price List €12.55/pc
Quantity

Fuse NH000/NH00C AC 690V aM 120 kA 25A insulated cover

Reference 2045208.25.0 - Manufacturer SIBA
Class aM
Rated current In (A) 25
Rated Voltage Un AC (V) 690
Dimension NH00C
Applicable standards IEC
Power loss (W) 1,4
Melting I²t value (A²s) 1441
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 5500
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 130
Price List €22.74/pc
Quantity
Product added to compare.
Product added to wishlist