List of products by manufacturer SIBA

Fuse 7,2kV 76x359 back-up FA2 125A

Reference 3013736.125.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 125
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Fuse Dimension (mm) 76x359
Melting I²t value (A²s) 81000
Fuse Connection/Terminal type BS
Voltage of total clearing I2t test 7200
Total clearing I²t @Un AC (A²s) 241000
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 2000
Product available on request Ask for more information

Fuse 7,2kV 76x359 back-up FA2 100A

Reference 3013736.100.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 100
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Fuse Dimension (mm) 76x359
Melting I²t value (A²s) 52900
Fuse Connection/Terminal type BS
Voltage of total clearing I2t test 7200
Total clearing I²t @Un AC (A²s) 158000
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 2000
Price List €378.16/pc
Quantity

Fuse 7,2kV 76x359 back-up FA2 140A

Reference 3013736.140.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 140
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Fuse Dimension (mm) 76x359
Melting I²t value (A²s) 100000
Fuse Connection/Terminal type BS
Voltage of total clearing I2t test 7200
Total clearing I²t @Un AC (A²s) 300000
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 2000
Product available on request Ask for more information

Fuse DIN Motors 12kV 87x442 striker no temp-limit 250A

Reference 3010354.250LM.0 - Manufacturer SIBA
Class HH Motors
Rated current In (A) 250
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 120
Fuse Dimension (mm) 87x442
Melting I²t value (A²s) 307000
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 12000
Total clearing I²t @Un AC (A²s) 1900000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 5671
Price List €666.88/pc
Quantity

Fuse DIN Motors 12kV 85x442 +striker no temp-limit 200A

Reference 3010354.200.0 - Manufacturer SIBA
Class HH Motors
Rated current In (A) 200
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 134
Fuse Dimension (mm) 85x442
Melting I²t value (A²s) 121000
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 12000
Total clearing I²t @Un AC (A²s) 789000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 5671
Price List €489.02/pc
Quantity

Fuse DIN Motors 12kV 85x442 with striker 160A 80N

Reference 3010353.160.0 - Manufacturer SIBA
Class HH Motors
Rated current In (A) 160
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 126
Fuse Dimension (mm) 85x442
Melting I²t value (A²s) 64000
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 12000
Total clearing I²t @Un AC (A²s) 417000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 5600
Price List €389.78/pc
Quantity

Fuse 12kV 85x442 SSK with striker 160A 80N

Reference 3010343.160.0 - Manufacturer SIBA
Class HH SSK
Rated current In (A) 160
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 125
Resistance (ohm) 4,5
Fuse Dimension (mm) 85x442
Melting I²t value (A²s) 50000
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 12000
Total clearing I²t @Un AC (A²s) 405000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 5720
Price List €305.98/pc
Quantity

Fuse 12kV 85x442 back-up striker no temp.lim200ARC180

Reference 3010314.200.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 200
Rated Voltage Un AC (V) 6000
Applicable standards IEC
Power loss (W) 134
Resistance (ohm) 0,0027
Fuse Dimension (mm) 85x442
Melting I²t value (A²s) 227800
Minimum breaking current (A) 870
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 5220
Total clearing I²t @Un AC (A²s) 1300000
Rated breaking capacity I1 AC (kA) 80000
Weight (gr) 5700
Price List €347.52/pc
Quantity

Fuse 12kV 87x442 full range with striker 125A 80N

Reference 3010303.125.0 - Manufacturer SIBA
Class HHD full
Rated current In (A) 125
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 122
Resistance (ohm) 4,8
Fuse Dimension (mm) 87x442
Melting I²t value (A²s) 39200
Fuse Connection/Terminal type Cylindrical
Total clearing I²t @Un AC (A²s) 141000
Rated breaking capacity I1 AC (kA) 80000
Price List €1,535.95/pc
Quantity

Fuse 12kV 85x442 back-up with striker 160ARC140 80N

Reference 3010313.160.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 160
Rated Voltage Un AC (V) 6000
Applicable standards IEC
Power loss (W) 117
Resistance (ohm) 0,004
Fuse Dimension (mm) 85x442
Melting I²t value (A²s) 78000
Minimum breaking current (A) 600
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 5220
Total clearing I²t @Un AC (A²s) 650000
Rated breaking capacity I1 AC (kA) 80000
Weight (gr) 5730
Price List €263.01/pc
Quantity

Fuse 12kV 85x442 SSK with striker 125A 80N

Reference 3010343.125.0 - Manufacturer SIBA
Class HH SSK
Rated current In (A) 125
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 128
Resistance (ohm) 4,8
Fuse Dimension (mm) 85x442
Melting I²t value (A²s) 39000
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 12000
Total clearing I²t @Un AC (A²s) 323000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 5720
Price List €544.45/pc
Quantity

Fuse 12kV 87x442 back-up striker no temp.lim250ARC200

Reference 3010314.250LM.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 250
Rated Voltage Un AC (V) 6000
Applicable standards IEC
Power loss (W) 148
Resistance (ohm) 0,0024
Fuse Dimension (mm) 85x442
Melting I²t value (A²s) 265700
Minimum breaking current (A) 1000
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 5220
Total clearing I²t @Un AC (A²s) 1800000
Rated breaking capacity I1 AC (kA) 80000
Price List €606.83/pc
Quantity
Product added to compare.
Product added to wishlist