List of products by manufacturer SIBA

Fuse NH1 gG 500V with striker 50A

Reference 2000913.50.0 - Manufacturer SIBA
Class aM
Rated current In (A) 50
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 5,1
Melting I²t value (A²s) 5900
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 13600
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 410
Price List €208.41/pc
Quantity

Fuse NH1 gG 500V with striker 63A

Reference 2000913.63.0 - Manufacturer SIBA
Class aM
Rated current In (A) 63
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 5,8
Melting I²t value (A²s) 10300
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 26400
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 410
Price List €209.55/pc
Quantity

Fuse NH1 gG 500V with striker 80A

Reference 2000913.80.0 - Manufacturer SIBA
Class aM
Rated current In (A) 80
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 6,5
Melting I²t value (A²s) 17300
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 45500
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 410
Price List €209.55/pc
Quantity

Fuse NH2 gR 500V with striker 100A

Reference 2001004.100.0 - Manufacturer SIBA
Class gR
Rated current In (A) 100
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC, UL
Power loss (W) 23
Melting I²t value (A²s) 920
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 7600
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 660
Product available on request Ask for more information

Fuse NH2 aR 500V with striker 125A

Reference 2001004.125.0 - Manufacturer SIBA
Class aR
Rated current In (A) 125
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC, UL
Power loss (W) 29
Melting I²t value (A²s) 1660
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 12300
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 660
Price List €397.10/pc
Quantity

Fuse NH2 aR 500V with striker 160A

Reference 2001004.160.0 - Manufacturer SIBA
Class aR
Rated current In (A) 160
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC, UL
Power loss (W) 40
Melting I²t value (A²s) 2400
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 19500
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 660
Product available on request Ask for more information

Fuse NH2 aR 500V with striker 200A

Reference 2001004.200.0 - Manufacturer SIBA
Class aR
Rated current In (A) 200
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC, UL
Power loss (W) 40
Melting I²t value (A²s) 5800
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 37000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 660
Price List €401.27/pc
Quantity

Fuse NH2 aR 500V with striker 224A

Reference 2001004.224.0 - Manufacturer SIBA
Class aR
Rated current In (A) 224
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC, UL
Power loss (W) 44
Melting I²t value (A²s) 7600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 39000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 660
Price List €414.22/pc
Quantity

Fuse NH2 aR 500V with striker 250A

Reference 2001004.250.0 - Manufacturer SIBA
Class aR
Rated current In (A) 250
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC, UL
Power loss (W) 51
Melting I²t value (A²s) 9600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 51000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 660
Price List €68.46/pc
Quantity

Fuse NH2 aR 500V with striker 315A

Reference 2001004.315.0 - Manufacturer SIBA
Class aR
Rated current In (A) 315
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC, UL
Power loss (W) 69
Melting I²t value (A²s) 14000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 84000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 660
Price List €71.09/pc
Quantity

Fuse NH2 gR 500V with striker 32A

Reference 2001004.32.0 - Manufacturer SIBA
Class gR
Rated current In (A) 32
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC, UL
Power loss (W) 7,4
Melting I²t value (A²s) 67
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 550
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 660
Product available on request Ask for more information

Fuse NH2 aR 500V with striker 355A

Reference 2001004.355.0 - Manufacturer SIBA
Class aR
Rated current In (A) 355
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC, UL
Power loss (W) 81
Melting I²t value (A²s) 20000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 125000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 660
Price List €468.77/pc
Quantity

Fuse NH2 gR 500V with striker 40A

Reference 2001004.40.0 - Manufacturer SIBA
Class gR
Rated current In (A) 40
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC, UL
Power loss (W) 9,2
Melting I²t value (A²s) 90
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 740
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 660
Product available on request Ask for more information

Fuse NH2 aR 500V with striker 400A

Reference 2001004.400.0 - Manufacturer SIBA
Class aR
Rated current In (A) 400
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC, UL
Power loss (W) 94
Melting I²t value (A²s) 27000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 155000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 660
Price List €75.37/pc
Quantity

Fuse NH2 gR 500V with striker 50A

Reference 2001004.50.0 - Manufacturer SIBA
Class gR
Rated current In (A) 50
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC, UL
Power loss (W) 11,5
Melting I²t value (A²s) 190
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 1560
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 660
Product available on request Ask for more information

Fuse NH2 gR 500V with striker 63A

Reference 2001004.63.0 - Manufacturer SIBA
Class gR
Rated current In (A) 63
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC, UL
Power loss (W) 14.5
Melting I²t value (A²s) 330
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 2700
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 660
Product available on request Ask for more information

Fuse NH2 gR 500V with striker 80A

Reference 2001004.80.0 - Manufacturer SIBA
Class gR
Rated current In (A) 80
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC, UL
Power loss (W) 18
Melting I²t value (A²s) 510
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 4200
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 660
Product available on request Ask for more information

Fuse NH2 gG 500V with striker 100A

Reference 2001013.100.0 - Manufacturer SIBA
Class aM
Rated current In (A) 100
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC
Power loss (W) 7,8
Melting I²t value (A²s) 28900
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 88600
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 650
Price List €28.87/pc
Quantity

Fuse NH2 gG 500V with striker 125A

Reference 2001013.125.0 - Manufacturer SIBA
Class aM
Rated current In (A) 125
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC
Power loss (W) 10
Melting I²t value (A²s) 44400
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 127500
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 650
Price List €256.22/pc
Quantity

Fuse NH2 gG 500V with striker 160A

Reference 2001013.160.0 - Manufacturer SIBA
Class aM
Rated current In (A) 160
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC
Power loss (W) 12,8
Melting I²t value (A²s) 78500
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 226600
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 650
Price List €259.44/pc
Quantity

Fuse NH2 gG 500V with striker 200A

Reference 2001013.200.0 - Manufacturer SIBA
Class aM
Rated current In (A) 200
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC
Power loss (W) 15.5
Melting I²t value (A²s) 157600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 390900
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 650
Price List €259.46/pc
Quantity

Fuse NH2 gG 500V with striker 224A

Reference 2001013.224.0 - Manufacturer SIBA
Class aM
Rated current In (A) 224
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC
Power loss (W) 16,4
Melting I²t value (A²s) 194800
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 483400
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 650
Price List €31.93/pc
Quantity

Fuse NH2 gG 500V with striker 250A

Reference 2001013.250.0 - Manufacturer SIBA
Class aM
Rated current In (A) 250
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC
Power loss (W) 18
Melting I²t value (A²s) 240800
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 616000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 650
Price List €275.27/pc
Quantity

Fuse NH2 gG 500V with striker 315A

Reference 2001013.315.0 - Manufacturer SIBA
Class aM
Rated current In (A) 315
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC
Power loss (W) 23
Melting I²t value (A²s) 513000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 1164000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 650
Price List €301.84/pc
Quantity
Product added to compare.
Product added to wishlist