List of products by manufacturer SIBA

Fuse 24kV 67x292 back-up with striker 40A 80N

Reference 3022513.40.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 40
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 115
Resistance (ohm) 0,043
Fuse Dimension (mm) 67x292
Melting I²t value (A²s) 2600
Minimum breaking current (A) 160
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 20880
Total clearing I²t @Un AC (A²s) 19000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2580
Price List €283.09/pc
Quantity

Fuse 24kV 67x292 back-up with striker 50ARC45 80N

Reference 3022513.50.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 50
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 108
Resistance (ohm) 0,032
Fuse Dimension (mm) 67x292
Melting I²t value (A²s) 4900
Minimum breaking current (A) 215
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 20880
Total clearing I²t @Un AC (A²s) 34000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2550
Price List €355.98/pc
Quantity

Fuse 17,5kV 85x292 back-up with striker 160ARC100 80N

Reference 3022213.160.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 160
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 115
Resistance (ohm) 0,0071
Fuse Dimension (mm) 85x292
Melting I²t value (A²s) 42000
Minimum breaking current (A) 600
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 375000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 3900
Price List €382.77/pc
Quantity

Fuse 24kV 53x292 back-up with striker 3,15A

Reference 3018013.3,15.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 3,15
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 18
Resistance (ohm) 1,3
Fuse Dimension (mm) 53x292
Melting I²t value (A²s) 17
Minimum breaking current (A) 24
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 20880
Total clearing I²t @Un AC (A²s) 48
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 1640
Price List €84.29/pc
Quantity

Fuse 24kV 53x292 back-up with striker 4A

Reference 3018013.4.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 4
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 22
Resistance (ohm) 0,95
Fuse Dimension (mm) 53x292
Melting I²t value (A²s) 31
Minimum breaking current (A) 32
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 20880
Total clearing I²t @Un AC (A²s) 90
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 1640
Price List €84.09/pc
Quantity

Fuse 24kV 53x292 back-up with striker 5A

Reference 3018013.5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 5
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 15
Resistance (ohm) 0,806
Fuse Dimension (mm) 53x292
Melting I²t value (A²s) 40
Minimum breaking current (A) 40
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 20880
Total clearing I²t @Un AC (A²s) 125
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 1640
Price List €133.00/pc
Quantity

Fuse 24kV 53x292 back-up with striker 6,3A 80N

Reference 3018013.6,3.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 6,3
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 29
Resistance (ohm) 0,554
Fuse Dimension (mm) 53x292
Melting I²t value (A²s) 27
Minimum breaking current (A) 22
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 20880
Total clearing I²t @Un AC (A²s) 530
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 1640
Price List €130.21/pc
Quantity

Fuse 36kV 53x442 back-up without striker 2,5A

Reference 3018111.2,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 2,5
Rated Voltage Un AC (V) 36000
Applicable standards IEC
Power loss (W) 22
Resistance (ohm) 2,6
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 7,2
Minimum breaking current (A) 20
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 31320
Total clearing I²t @Un AC (A²s) 23
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 1600
Price List €517.71/pc
Quantity

Fuse 36kV 53x442 back-up without striker 3,15A

Reference 3018111.3,15.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 3,15
Rated Voltage Un AC (V) 36000
Applicable standards IEC
Power loss (W) 26
Resistance (ohm) 1,9
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 17
Minimum breaking current (A) 24
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 31320
Total clearing I²t @Un AC (A²s) 48
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 1600
Price List €518.58/pc
Quantity

Fuse 36kV 53x442 back-up without striker 2A

Reference 3018111.2.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 2
Rated Voltage Un AC (V) 36000
Applicable standards IEC
Power loss (W) 23
Resistance (ohm) 4,26
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 3,2
Minimum breaking current (A) 16
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 31320
Total clearing I²t @Un AC (A²s) 9,8
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 1600
Price List €110.66/pc
Quantity

Fuse 36kV 53x442 back-up no striker 0,5A

Reference 3018111.0,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 0,5
Rated Voltage Un AC (V) 36000
Applicable standards IEC
Power loss (W) 17
Resistance (ohm) 60,8
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 1,6
Minimum breaking current (A) 5
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 31320
Total clearing I²t @Un AC (A²s) 5,9
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 1600
Price List €87.05/pc
Quantity

Fuse 36kV 53x442 back-up no striker 1A

Reference 3018111.1.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 1
Rated Voltage Un AC (V) 36000
Applicable standards IEC
Power loss (W) 13
Resistance (ohm) 9,57
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 0,63
Minimum breaking current (A) 8
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 31320
Total clearing I²t @Un AC (A²s) 2,8
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 2300
Price List €87.06/pc
Quantity
Product added to compare.
Product added to wishlist