Fuse 7,2kV 51x359 back-up 40A

Reference 3024236.40.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 40
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Fuse Dimension (mm) 51x359
Melting I²t value (A²s) 4900
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 7200
Total clearing I²t @Un AC (A²s) 14800
Rated breaking capacity I1 AC (kA) 40000
Product available on request Ask for more information

Fuse 7,2kV 51x359 back-up 50A

Reference 3024236.50.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 50
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Fuse Dimension (mm) 51x359
Melting I²t value (A²s) 8100
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 7200
Total clearing I²t @Un AC (A²s) 24000
Rated breaking capacity I1 AC (kA) 40000
Product available on request Ask for more information

Fuse 7,2kV 51x359 back-up 63A

Reference 3024236.63.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 63
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Fuse Dimension (mm) 51x359
Melting I²t value (A²s) 16200
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 7200
Total clearing I²t @Un AC (A²s) 48000
Rated breaking capacity I1 AC (kA) 40000
Product available on request Ask for more information

Fuse 7,2kV 51x359 back-up 6,3A

Reference 3024236.6,3.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 6,3
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Fuse Dimension (mm) 51x359
Melting I²t value (A²s) 50
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 7200
Total clearing I²t @Un AC (A²s) 150
Rated breaking capacity I1 AC (kA) 40000
Product available on request Ask for more information

Fuse 12kV 51x359 back-up FA1 25A

Reference 3024336.25.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 25
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Fuse Dimension (mm) 51x359
Melting I²t value (A²s) 1160
Fuse Connection/Terminal type BS
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 3500
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 2000
Product available on request Ask for more information

Fuse 12kV 51x359 back-up FA1 20A

Reference 3024336.20.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 20
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Fuse Dimension (mm) 51x359
Melting I²t value (A²s) 650
Fuse Connection/Terminal type BS
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 1950
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 2000
Price List €256.22/pc
Quantity

Fuse 12kV 51x359 back-up FA1 10A

Reference 3024336.10.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 10
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Fuse Dimension (mm) 51x359
Melting I²t value (A²s) 120
Fuse Connection/Terminal type BS
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 340
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 2000
Product available on request Ask for more information

Fuse 7,2kV 51x359 back-up 80A

Reference 3024236.80.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 80
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Fuse Dimension (mm) 51x359
Melting I²t value (A²s) 27200
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 7200
Total clearing I²t @Un AC (A²s) 81000
Rated breaking capacity I1 AC (kA) 40000
Product available on request Ask for more information

Fuse 12kV 51x359 back-up FA1 16A

Reference 3024336.16.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 16
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Fuse Dimension (mm) 51x359
Melting I²t value (A²s) 270
Fuse Connection/Terminal type BS
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 800
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 2000
Price List €254.64/pc
Quantity

Fuse 24kV 67x537 back-up with striker 63A 80N

Reference 3020413.63.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 63
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 126
Resistance (ohm) 0,022
Fuse Dimension (mm) 67x537
Melting I²t value (A²s) 8700
Minimum breaking current (A) 210
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 20880
Total clearing I²t @Un AC (A²s) 87000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 4290
Price List €590.03/pc
Quantity

Fuse 24kV 67x537 back-up with striker 80A 80N

Reference 3020413.80.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 80
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 170
Resistance (ohm) 0,017
Fuse Dimension (mm) 67x537
Melting I²t value (A²s) 17500
Minimum breaking current (A) 280
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 20880
Total clearing I²t @Un AC (A²s) 119000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 4290
Price List €643.31/pc
Quantity

Fuse DIN Motors 3,6kV 2x85x292 double body 355A striker120N

Reference 3020554.355.0 - Manufacturer SIBA
Class HH Motors
Rated current In (A) 355
Rated Voltage Un AC (V) 36000
Applicable standards IEC
Power loss (W) 82
Fuse Dimension (mm) 2x 85x292
Melting I²t value (A²s) 754000
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 36000
Total clearing I²t @Un AC (A²s) 2360000
Rated breaking capacity I1 AC (kA) 50000
Weight (gr) 7600
Price List €3,384.84/pc
Quantity
Product added to compare.