List of products by manufacturer SIBA

Fuse 24kV 63,5x360 general purpose without striker 12A

Reference 3031291.12.0 - Manufacturer SIBA
Class HH G P
Rated current In (A) 12
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 24
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 460
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 5100
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2450
Price List €973.18/pc
Quantity

Fuse 24kV 63,5x360 general purpose without striker 10A

Reference 3031291.10.0 - Manufacturer SIBA
Class HH G P
Rated current In (A) 10
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 21
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 250
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 3200
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2450
Price List €971.38/pc
Quantity

Fuse 24kV 63,5x360 M8 oiltight with striker 10A 50N

Reference 3031215.10.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 10
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 54
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 70
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 400
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2529
Price List €869.37/pc
Quantity

Fuse 24kV 63,5x360 M8-G1/8” oiltight with striker 80A 50N

Reference 3031216.80.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 80
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 176
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 15500
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 150000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2000
Product available on request Ask for more information

Fuse 24kV 63,5x360 M8-G1/8” oiltight with striker 63A 50N

Reference 3031216.63.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 63
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 114
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 8700
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 87000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2000
Product available on request Ask for more information

Fuse 24kV 63,5x360 M8-G1/8” oiltight with striker 6,3A 50N

Reference 3031216.6,3.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 6,3
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 30
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 30
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 160
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2590
Product available on request Ask for more information

Fuse 24kV 63,5x360 M8-G1/8” oiltight with striker 40A 50N

Reference 3031216.40.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 40
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 94
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 2200
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 22000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2000
Product available on request Ask for more information

Fuse 24kV 63,5x360 M8-G1/8” oiltight with striker 31,5A 50N

Reference 3031216.31,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 31,5
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 76
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 1400
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 14000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2000
Product available on request Ask for more information

Fuse 24kV 63,5x360 M8-G1/8” oiltight with striker 25A 50N

Reference 3031216.25.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 25
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 58
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 920
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 9200
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2000
Product available on request Ask for more information

Fuse 24kV 63,5x360 M8-G1/8” oiltight with striker 20A 50N

Reference 3031216.20.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 20
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 28
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 550
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 5500
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2000
Product available on request Ask for more information

Fuse 24kV 63,5x360 M8-G1/8” oiltight with striker 16A 50N

Reference 3031216.16.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 16
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 61
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 120
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 1200
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2000
Price List €791.64/pc
Quantity

Fuse 24kV 63,5x360 M8-G1/8” oiltight with striker 10A 50N

Reference 3031216.10.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 10
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 54
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 70
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 400
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2590
Product available on request Ask for more information

Fuse 24kV 63,5x360 M8 oiltight with striker 80A 50N

Reference 3031215.80.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 80
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 176
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 15500
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 150000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2519
Price List €153.43/pc
Quantity

Fuse 24kV 63,5x360 M8 oiltight with striker 63A 50N

Reference 3031215.63.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 63
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 144
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 8700
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 87000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2519
Price List €150.12/pc
Quantity

Fuse 24kV 63,5x360 M8 oiltight with striker 6,3A 50N

Reference 3031215.6,3.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 6,3
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 30
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 30
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 160
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2590
Price List €868.78/pc
Quantity

Fuse 24kV 63,5x360 M8 oiltight with striker 50A 50N

Reference 3031215.50.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 50
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 108
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 4700
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 47000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2519
Product available on request Ask for more information

Fuse 24kV 63,5x360 M8 oiltight with striker 40A 50N

Reference 3031215.40.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 40
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 94
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 2200
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 22000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2519
Price List €193.66/pc
Quantity

Fuse 24kV 63,5x360 M8 oiltight with striker 31,5A 50N

Reference 3031215.31,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 31,5
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 76
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 1400
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 14000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2519
Price List €962.77/pc
Quantity

Fuse 24kV 63,5x360 M8 oiltight with striker 25A 50N

Reference 3031215.25.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 25
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 58
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 920
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 9200
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2519
Price List €181.50/pc
Quantity

Fuse 24kV 63,5x360 M8 oiltight with striker 20A 50N

Reference 3031215.20.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 20
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 28
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 550
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 5500
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2519
Price List €872.31/pc
Quantity

Fuse 24kV 63,5x360 M8-G1/8” oiltight with striker 50A 50N

Reference 3031216.50.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 50
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 108
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 4700
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 47000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2000
Product available on request Ask for more information

Fuse 213x27 3000V DC 16A

Reference 3030801.16.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 16
Power loss (W) 9,4
Rated Voltage Un DC (V) 3000
Time costant L/R (ms) 10
Rated breaking capacity I1 DC (kA) 50000
Fuse Dimension (mm) 27x213
Melting I²t value (A²s) 185
Fuse Connection/Terminal type Cylindrical
Weight (gr) 480
Price List €549.18/pc
Quantity

Fuse 213x27 3000V DC 10A

Reference 3030801.10.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 10
Power loss (W) 10
Rated Voltage Un DC (V) 3000
Time costant L/R (ms) 10
Rated breaking capacity I1 DC (kA) 50000
Fuse Dimension (mm) 27x213
Melting I²t value (A²s) 68
Fuse Connection/Terminal type Cylindrical
Weight (gr) 480
Price List €548.09/pc
Quantity

Fuse 27x178 3000V DC 6,3A

Reference 3030701.6,3.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 6,3
Power loss (W) 10
Rated Voltage Un DC (V) 3000
Rated breaking capacity I1 DC (kA) 30000
Fuse Dimension (mm) 178x27
Melting I²t value (A²s) 75
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 3000
Total clearing I²t @Un AC (A²s) 190
Weight (gr) 190
Price List €524.93/pc
Quantity

Fuse 27x178 3000V DC 3,15A

Reference 3030701.3,15.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 3,15
Power loss (W) 4,7
Rated Voltage Un DC (V) 3000
Rated breaking capacity I1 DC (kA) 30000
Fuse Dimension (mm) 178x27
Melting I²t value (A²s) 16
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 3000
Total clearing I²t @Un AC (A²s) 40
Weight (gr) 254
Price List €288.14/pc
Quantity

Fuse 27x178 3000V DC 2A

Reference 3030701.2.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 2
Power loss (W) 3,9
Rated Voltage Un DC (V) 3000
Rated breaking capacity I1 DC (kA) 30000
Fuse Dimension (mm) 178x27
Melting I²t value (A²s) 2,5
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 3000
Total clearing I²t @Un AC (A²s) 6,5
Weight (gr) 190
Price List €116.27/pc
Quantity

Fuse 27x178 3000V DC 10A

Reference 3030701.10.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 10
Rated Voltage Un DC (V) 3000
Rated breaking capacity I1 DC (kA) 50000
Fuse Dimension (mm) 178x27
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15
Weight (gr) 190
Price List €525.02/pc
Quantity

Fuse 27x178 3000V DC 1A

Reference 3030701.1.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 1
Power loss (W) 2,5
Rated Voltage Un DC (V) 3000
Rated breaking capacity I1 DC (kA) 30000
Fuse Dimension (mm) 178x27
Melting I²t value (A²s) 0,64
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 3000
Total clearing I²t @Un AC (A²s) 1,6
Weight (gr) 190
Price List €63.56/pc
Quantity

Fuse 27x178 3000V DC 0,5A

Reference 3030701.0,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 0,5
Power loss (W) 2
Rated Voltage Un DC (V) 3000
Rated breaking capacity I1 DC (kA) 30000
Fuse Dimension (mm) 178x27
Melting I²t value (A²s) 0,13
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 3000
Total clearing I²t @Un AC (A²s) 0,4
Weight (gr) 190
Price List €63.83/pc
Quantity

Fuse 213x27 2400VDC 25A

Reference 3030601.25.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 25
Power loss (W) 10
Rated Voltage Un DC (V) 2400
Rated breaking capacity I1 DC (kA) 50000
Fuse Dimension (mm) 27x213
Melting I²t value (A²s) 650
Fuse Connection/Terminal type Cylindrical
Weight (gr) 310
Price List €519.34/pc
Quantity

Fuse 27x178 2400VDC 6,3A

Reference 3030501.6,3.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 6,3
Power loss (W) 5,2
Rated Voltage Un DC (V) 2400
Rated breaking capacity I1 DC (kA) 50000
Fuse Dimension (mm) 178x27
Melting I²t value (A²s) 28
Fuse Connection/Terminal type Cylindrical
Weight (gr) 190
Product available on request Ask for more information

Fuse 27x178 2400VDC 16A

Reference 3030501.16.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 16
Power loss (W) 7,5
Rated Voltage Un DC (V) 2400
Rated breaking capacity I1 DC (kA) 50000
Fuse Dimension (mm) 178x27
Melting I²t value (A²s) 185
Fuse Connection/Terminal type Cylindrical
Weight (gr) 190
Price List €470.85/pc
Quantity

Fuse 27x178 2400VDC 10A

Reference 3030501.10.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 10
Power loss (W) 8.5
Rated Voltage Un DC (V) 2400
Rated breaking capacity I1 DC (kA) 50000
Fuse Dimension (mm) 178x27
Melting I²t value (A²s) 68
Fuse Connection/Terminal type Cylindrical
Weight (gr) 190
Product available on request Ask for more information

Fuse 27x138 2400VDC 6,3A

Reference 3030401.6,3.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 6,3
Power loss (W) 2,5
Rated Voltage Un DC (V) 2400
Rated breaking capacity I1 DC (kA) 50000
Fuse Dimension (mm) 138x27
Melting I²t value (A²s) 28
Fuse Connection/Terminal type Cylindrical
Weight (gr) 190
Price List €406.36/pc
Quantity

Fuse 27x138 1500VDC 6,3A

Reference 3030101.6,3.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 6,3
Power loss (W) 2,5
Rated Voltage Un DC (V) 1500
Rated breaking capacity I1 DC (kA) 50000
Fuse Dimension (mm) 138x27
Melting I²t value (A²s) 28
Fuse Connection/Terminal type Cylindrical
Weight (gr) 190
Price List €376.77/pc
Quantity

Fuse 27x138 1500VDC 4A

Reference 3030101.4.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 4
Power loss (W) 2
Rated Voltage Un DC (V) 1500
Rated breaking capacity I1 DC (kA) 50000
Fuse Dimension (mm) 138x27
Melting I²t value (A²s) 7,5
Fuse Connection/Terminal type Cylindrical
Weight (gr) 190
Product available on request Ask for more information
Product added to compare.
Product added to wishlist