Home

Fuse 24kV 520x55 standard NCF with striker 50A 80N

Reference 3025813.50.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 50
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 101
Fuse Dimension (mm) 55x520
Melting I²t value (A²s) 6300
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2580
Price List €206.86/pc
Quantity

Fuse 24kV 520x55 standard NCF with striker 43A 80N

Reference 3025813.43.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 43
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 96
Fuse Dimension (mm) 55x520
Melting I²t value (A²s) 4900
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2580
Price List €198.37/pc
Quantity

Fuse 24kV 520x55 standard NCF with striker 32A 80N

Reference 3025813.32.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 32
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 69
Fuse Dimension (mm) 55x520
Melting I²t value (A²s) 2200
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2580
Price List €184.89/pc
Quantity

Fuse 24kV 520x55 standard NCF with striker 25A 80N

Reference 3025813.25.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 25
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 43
Fuse Dimension (mm) 55x520
Melting I²t value (A²s) 1400
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2550
Price List €839.39/pc
Quantity

Fuse BS Motors 3,6kV 305mm 100A

Reference 3026956.100.0 - Manufacturer SIBA
Class HH Motors
Rated current In (A) 100
Rated Voltage Un AC (V) 3600
Applicable standards IEC
Power loss (W) 39
Melting I²t value (A²s) 14000
Fuse Connection/Terminal type BS
Fixing connection centres (mm) 305
Total clearing I²t @Un AC (A²s) 65000
Rated breaking capacity I1 AC (kA) 50000
Weight (gr) 2820
Price List €350.05/pc
Quantity

Fuse 24kV 520x55 standard NCF with striker 20A 80N

Reference 3025813.20.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 20
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 43
Fuse Dimension (mm) 55x520
Melting I²t value (A²s) 920
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2550
Price List €173.98/pc
Quantity

Fuse 17,5kV 85x442 back-up with striker 50A 80N

Reference 3023213.50.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 50
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 74
Resistance (ohm) 0,021
Fuse Dimension (mm) 67x442
Melting I²t value (A²s) 4700
Minimum breaking current (A) 170
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 33000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 3710
Price List €616.27/pc
Quantity

Fuse 17,5kV 67x442 back-up with striker 6,3A 80N

Reference 3023113.6,3.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 6,3
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 21
Resistance (ohm) 0,402
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 27
Minimum breaking current (A) 22
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 520
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2280
Price List €209.74/pc
Quantity

Fuse 17,5kV 67x442 back-up with striker 40A 80N

Reference 3023113.40.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 40
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 65
Resistance (ohm) 0,029
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 2500
Minimum breaking current (A) 140
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 17500
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2360
Price List €534.81/pc
Quantity

Fuse 17,5kV 67x442 back-up with striker 31,5A 80N

Reference 3023113.31,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 31,5
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 53
Resistance (ohm) 0,039
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 1400
Minimum breaking current (A) 110
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 9800
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2600
Price List €513.79/pc
Quantity

Fuse 17,5kV 67x442 back-up with striker 3,15A 80N

Reference 3023113.3,15.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 3,15
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 13
Resistance (ohm) 0,92
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 17
Minimum breaking current (A) 24
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 48
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2340
Price List €133.53/pc
Quantity

Fuse 17,5kV 85x442 back-up with striker 160ARC125 80N

Reference 3023313.160.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 160
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 138
Resistance (ohm) 0,0059
Fuse Dimension (mm) 85x442
Melting I²t value (A²s) 62000
Minimum breaking current (A) 600
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 437000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 5620
Price List €599.36/pc
Quantity

Fuse 17,5kV 67x442 back-up with striker 25A 80N

Reference 3023113.25.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 25
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 41
Resistance (ohm) 0,048
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 920
Minimum breaking current (A) 90
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 5400
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2280
Price List €507.17/pc
Quantity

Fuse 17,5kV 67x442 back-up with striker 20A 80N

Reference 3023113.20.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 20
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 34
Resistance (ohm) 0,062
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 545
Minimum breaking current (A) 70
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 4400
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2280
Price List €503.11/pc
Quantity

Fuse 17,5kV 67x442 back-up with striker 2A 80N

Reference 3023113.2.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 2
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 11
Resistance (ohm) 2,06
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 3,2
Minimum breaking current (A) 16
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 9,8
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2340
Price List €413.94/pc
Quantity

Fuse 17,5kV 67x442 back-up with striker 16A 80N

Reference 3023113.16.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 16
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 43
Resistance (ohm) 0,123
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 140
Minimum breaking current (A) 56
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 2400
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2280
Price List €659.35/pc
Quantity

Fuse 17,5kV 67x442 back-up with striker 10A 80N

Reference 3023113.10.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 10
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 35
Resistance (ohm) 0,256
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 68
Minimum breaking current (A) 34
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 680
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2280
Price List €496.60/pc
Quantity

Fuse 24kV 67x292 back-up with striker 63ARC50 80N

Reference 3022513.63.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 63
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 115
Resistance (ohm) 0,024
Fuse Dimension (mm) 67x292
Melting I²t value (A²s) 8700
Minimum breaking current (A) 285
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 20880
Total clearing I²t @Un AC (A²s) 61000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2590
Price List €381.92/pc
Quantity

Fuse 24kV 67x292 back-up with striker 6,3A 80N

Reference 3022513.6,3.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 6,3
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Fuse Dimension (mm) 67x292
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 20880
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2550
Price List €155.45/pc
Quantity

Fuse 24kV 67x292 back-up with striker 50ARC45 80N

Reference 3022513.50.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 50
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 108
Resistance (ohm) 0,032
Fuse Dimension (mm) 67x292
Melting I²t value (A²s) 4900
Minimum breaking current (A) 215
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 20880
Total clearing I²t @Un AC (A²s) 34000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2550
Price List €355.99/pc
Quantity

Fuse 24kV 67x292 back-up with striker 40A 80N

Reference 3022513.40.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 40
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 115
Resistance (ohm) 0,043
Fuse Dimension (mm) 67x292
Melting I²t value (A²s) 2600
Minimum breaking current (A) 160
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 20880
Total clearing I²t @Un AC (A²s) 19000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2580
Price List €283.09/pc
Quantity

Fuse 10/17,5kV 31,5A

Reference 3022114.31,5.0 - Manufacturer SIBA
Price List €167.60/pc
Quantity

Fuse 17,5kV 67x292 back-up without striker 2A

Reference 3022111.2.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 2
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Fuse Dimension (mm) 67x292
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 63000
Rated breaking capacity I1 AC (kA) 17500
Weight (gr) 2540
Price List €117.45/pc
Quantity

Fuse 17,5kV 67x292 back-up with striker 20A 80N

Reference 3022113.20.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 20
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 36
Resistance (ohm) 0,062
Fuse Dimension (mm) 67x292
Melting I²t value (A²s) 545
Minimum breaking current (A) 70
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 4400
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2540
Price List €281.18/pc
Quantity

Fuse 17,5kV 67x292 back-up with striker 25A 80N

Reference 3022113.25.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 25
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 43
Resistance (ohm) 0,048
Fuse Dimension (mm) 67x292
Melting I²t value (A²s) 920
Minimum breaking current (A) 90
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 5400
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2540
Price List €287.51/pc
Quantity

Fuse 17,5kV 67x292 back-up with striker 31,5A 80N

Reference 3022113.31,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 31,5
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 56
Resistance (ohm) 0,039
Fuse Dimension (mm) 67x292
Melting I²t value (A²s) 1400
Minimum breaking current (A) 110
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 9800
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2550
Price List €294.09/pc
Quantity

Fuse 17,5kV 67x292 back-up with striker 40A 80N

Reference 3022113.40.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 40
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 71
Resistance (ohm) 0,029
Fuse Dimension (mm) 67x292
Melting I²t value (A²s) 2500
Minimum breaking current (A) 140
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 17500
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2550
Price List €297.22/pc
Quantity

Fuse 17,5kV 67x292 back-up with striker 50A 80N

Reference 3022113.50.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 50
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 81
Resistance (ohm) 0,021
Fuse Dimension (mm) 67x292
Melting I²t value (A²s) 4700
Minimum breaking current (A) 170
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 33000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2550
Price List €304.62/pc
Quantity

Fuse 17,5kV 67x292 back-up with striker 63ARC56 80N

Reference 3022113.63.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 63
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 71
Resistance (ohm) 0,016
Fuse Dimension (mm) 67x292
Melting I²t value (A²s) 8700
Minimum breaking current (A) 210
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 61400
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2550
Price List €312.55/pc
Quantity

Fuse 17,5kV 85x292 back-up with striker 160ARC100 80N

Reference 3022213.160.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 160
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 115
Resistance (ohm) 0,0071
Fuse Dimension (mm) 85x292
Melting I²t value (A²s) 42000
Minimum breaking current (A) 600
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 375000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 3900
Price List €382.82/pc
Quantity

Fuse 24kV 67x292 back-up with striker 25A 80N

Reference 3022513.25.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 25
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 56
Resistance (ohm) 0,066
Fuse Dimension (mm) 67x292
Melting I²t value (A²s) 920
Minimum breaking current (A) 90
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 20880
Total clearing I²t @Un AC (A²s) 11000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2550
Price List €262.04/pc
Quantity

Fuse 24kV 67x292 back-up with striker 20A 80N

Reference 3022513.20.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 20
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 46
Resistance (ohm) 0,086
Fuse Dimension (mm) 67x292
Melting I²t value (A²s) 545
Minimum breaking current (A) 70
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 20880
Total clearing I²t @Un AC (A²s) 7000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2550
Price List €262.48/pc
Quantity

Fuse 17,5kV 85x292 back-up with striker 80ARC75 80N

Reference 3022213.80.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 80
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 93
Resistance (ohm) 0,011
Fuse Dimension (mm) 85x292
Melting I²t value (A²s) 17500
Minimum breaking current (A) 280
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 123300
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 3900
Price List €686.76/pc
Quantity

Fuse 24kV 67x292 back-up with striker 31,5A 80N

Reference 3022513.31,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 31,5
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 72
Resistance (ohm) 0,054
Fuse Dimension (mm) 67x292
Melting I²t value (A²s) 1400
Minimum breaking current (A) 110
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 20880
Total clearing I²t @Un AC (A²s) 16000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2550
Price List €269.36/pc
Quantity

Fuse 17,5kV 85x292 back-up with striker 125ARC95 80N

Reference 3022213.125.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 125
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 114
Resistance (ohm) 0,0079
Fuse Dimension (mm) 85x292
Melting I²t value (A²s) 35000
Minimum breaking current (A) 390
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 247000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 3900
Price List €333.20/pc
Quantity

Fuse 17,5kV 85x292 back-up with striker 100ARC90 80N

Reference 3022213.100.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 100
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 109
Resistance (ohm) 0,0087
Fuse Dimension (mm) 85x292
Melting I²t value (A²s) 28000
Minimum breaking current (A) 320
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 199000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 3900
Price List €316.44/pc
Quantity
Product added to compare.