Home

Fuse 10x38 gG 500V 0,5A

Reference 5006308.0,5.0 - Manufacturer SIBA
Class gG
Rated current In (A) 0,5
Rated Voltage Un AC (V) 500
Applicable standards IEC
Power loss (W) 1,6
Fuse Dimension (mm) 10x38
Melting I²t value (A²s) 0,08
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 0,35
Rated breaking capacity I1 AC (kA) 100000
Weight (gr) 10
Price List €2.21/pc
Quantity

Fuse 10x38 aM 500V 8A

Reference 5006307.8.0 - Manufacturer SIBA
Class aM
Rated current In (A) 8
Rated Voltage Un AC (V) 500
Applicable standards IEC
Fuse Dimension (mm) 10x38
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 500
Rated breaking capacity I1 AC (kA) 100000
Weight (gr) 10
Price List €1.60/pc
Quantity

Fuse 10x38 aM 500V 6A

Reference 5006307.6.0 - Manufacturer SIBA
Class aM
Rated current In (A) 6
Rated Voltage Un AC (V) 500
Applicable standards IEC
Power loss (W) 0,7
Fuse Dimension (mm) 10x38
Melting I²t value (A²s) 200
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 740
Rated breaking capacity I1 AC (kA) 100000
Weight (gr) 10
Price List €1.60/pc
Quantity

Fuse 10x38 aM 500V 4A

Reference 5006307.4.0 - Manufacturer SIBA
Class aM
Rated current In (A) 4
Rated Voltage Un AC (V) 500
Applicable standards IEC
Power loss (W) 0,4
Fuse Dimension (mm) 10x38
Melting I²t value (A²s) 100
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 370
Rated breaking capacity I1 AC (kA) 100000
Weight (gr) 10
Price List €1.54/pc
Quantity

Fuse 10x38 aM 400V 32A

Reference 5006307.32.0 - Manufacturer SIBA
Class aM
Rated current In (A) 32
Rated Voltage Un AC (V) 500
Applicable standards IEC
Power loss (W) 1,4
Fuse Dimension (mm) 10x38
Melting I²t value (A²s) 3600
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 400
Total clearing I²t @Un AC (A²s) 11200
Rated breaking capacity I1 AC (kA) 100000
Weight (gr) 9
Price List €1.63/pc
Quantity

Fuse 10x38 aM 500V 20A

Reference 5006307.20.0 - Manufacturer SIBA
Class aM
Rated current In (A) 20
Rated Voltage Un AC (V) 500
Applicable standards IEC
Power loss (W) 1,1
Fuse Dimension (mm) 10x38
Melting I²t value (A²s) 1100
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 4100
Rated breaking capacity I1 AC (kA) 100000
Weight (gr) 10
Price List €1.63/pc
Quantity

Fuse 22x58 aM 690V with striker 20A

Reference 5006107.20.0 - Manufacturer SIBA
Class aM
Rated current In (A) 20
Rated Voltage Un AC (V) 690
Applicable standards IEC
Power loss (W) 1,1
Fuse Dimension (mm) 22x58
Melting I²t value (A²s) 1100
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 6100
Rated breaking capacity I1 AC (kA) 100000
Weight (gr) 60
Price List €10.59/pc
Quantity

Fuse 22x58 aM 690V with striker 32A

Reference 5006107.32.0 - Manufacturer SIBA
Class aM
Rated current In (A) 32
Rated Voltage Un AC (V) 690
Applicable standards IEC
Power loss (W) 1,7
Fuse Dimension (mm) 22x58
Melting I²t value (A²s) 3600
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 12000
Rated breaking capacity I1 AC (kA) 100000
Weight (gr) 60
Price List €10.59/pc
Quantity

Fuse 22x58 aM 400V with striker 4A

Reference 5006107.4.0 - Manufacturer SIBA
Class aM
Rated current In (A) 4
Rated Voltage Un AC (V) 690
Applicable standards IEC
Power loss (W) 0,4
Fuse Dimension (mm) 22x58
Melting I²t value (A²s) 100
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 560
Rated breaking capacity I1 AC (kA) 100000
Weight (gr) 60
Price List €10.50/pc
Quantity

Fuse 22x58 aM 690V with striker 40A

Reference 5006107.40.0 - Manufacturer SIBA
Class aM
Rated current In (A) 40
Rated Voltage Un AC (V) 690
Applicable standards IEC
Power loss (W) 2,2
Fuse Dimension (mm) 22x58
Melting I²t value (A²s) 6400
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 24000
Rated breaking capacity I1 AC (kA) 100000
Weight (gr) 60
Price List €12.26/pc
Quantity

Fuse 22x58 aM 690V with striker 50A

Reference 5006107.50.0 - Manufacturer SIBA
Class aM
Rated current In (A) 50
Rated Voltage Un AC (V) 690
Applicable standards IEC
Power loss (W) 3
Fuse Dimension (mm) 22x58
Melting I²t value (A²s) 10600
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 58000
Rated breaking capacity I1 AC (kA) 100000
Weight (gr) 60
Price List €12.93/pc
Quantity

Fuse 22x58 aM 690V with striker 6A

Reference 5006107.6.0 - Manufacturer SIBA
Class aM
Rated current In (A) 6
Rated Voltage Un AC (V) 690
Applicable standards IEC
Power loss (W) 0,6
Fuse Dimension (mm) 22x58
Melting I²t value (A²s) 200
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 1200
Rated breaking capacity I1 AC (kA) 100000
Weight (gr) 60
Price List €10.50/pc
Quantity

Fuse 22x58 aM 690V with striker 63A

Reference 5006107.63.0 - Manufacturer SIBA
Class aM
Rated current In (A) 63
Rated Voltage Un AC (V) 690
Applicable standards IEC
Power loss (W) 3,2
Fuse Dimension (mm) 22x58
Melting I²t value (A²s) 19500
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 110000
Rated breaking capacity I1 AC (kA) 100000
Weight (gr) 60
Price List €14.42/pc
Quantity

Fuse 22x58 aM 690V with striker 80A

Reference 5006107.80.0 - Manufacturer SIBA
Class aM
Rated current In (A) 80
Rated Voltage Un AC (V) 690
Applicable standards IEC
Power loss (W) 3,9
Fuse Dimension (mm) 22x58
Melting I²t value (A²s) 34600
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 190000
Rated breaking capacity I1 AC (kA) 100000
Weight (gr) 60
Price List €14.42/pc
Quantity

Fuse 22x58 gG 690V with striker 10A

Reference 5006108.10.0 - Manufacturer SIBA
Class gG
Rated current In (A) 10
Rated Voltage Un AC (V) 690
Applicable standards IEC
Power loss (W) 1,5
Fuse Dimension (mm) 22x58
Melting I²t value (A²s) 380
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 570
Rated breaking capacity I1 AC (kA) 100000
Weight (gr) 60
Price List €10.23/pc
Quantity

Fuse 22x58 gG 500V with striker 100A

Reference 5006108.100.0 - Manufacturer SIBA
Class gG
Rated current In (A) 100
Rated Voltage Un AC (V) 500
Applicable standards IEC
Power loss (W) 9,2
Fuse Dimension (mm) 22x58
Melting I²t value (A²s) 44000
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 56000
Rated breaking capacity I1 AC (kA) 100000
Weight (gr) 60
Price List €14.19/pc
Quantity

Fuse 22x58 gG 690V with striker 2A

Reference 5006108.2.0 - Manufacturer SIBA
Class gG
Rated current In (A) 2
Rated Voltage Un AC (V) 690
Applicable standards IEC
Power loss (W) 1
Fuse Dimension (mm) 22x58
Melting I²t value (A²s) 1,5
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 14
Rated breaking capacity I1 AC (kA) 100000
Weight (gr) 60
Price List €10.23/pc
Quantity

Fuse 22x58 gG 690V with striker 32A

Reference 5006108.32.0 - Manufacturer SIBA
Class gG
Rated current In (A) 32
Rated Voltage Un AC (V) 690
Applicable standards IEC
Power loss (W) 3,8
Fuse Dimension (mm) 22x58
Melting I²t value (A²s) 2100
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 3400
Rated breaking capacity I1 AC (kA) 100000
Weight (gr) 60
Price List €10.73/pc
Quantity

Fuse 10x38 aM 500V 16A

Reference 5006307.16.0 - Manufacturer SIBA
Class aM
Rated current In (A) 16
Rated Voltage Un AC (V) 500
Applicable standards IEC
Power loss (W) 0,9
Fuse Dimension (mm) 10x38
Melting I²t value (A²s) 620
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 2300
Rated breaking capacity I1 AC (kA) 100000
Weight (gr) 9
Price List €1.60/pc
Quantity

Fuse 10x38 aM 500V 1A

Reference 5006307.1.0 - Manufacturer SIBA
Class aM
Rated current In (A) 1
Rated Voltage Un AC (V) 500
Applicable standards IEC
Power loss (W) 0,1
Fuse Dimension (mm) 10x38
Melting I²t value (A²s) 6,8
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 21
Rated breaking capacity I1 AC (kA) 100000
Weight (gr) 10
Price List €1.54/pc
Quantity

Fuse 10x38 aM 500V 10A

Reference 5006307.10.0 - Manufacturer SIBA
Class aM
Rated current In (A) 10
Rated Voltage Un AC (V) 500
Applicable standards IEC
Power loss (W) 0,55
Fuse Dimension (mm) 10x38
Melting I²t value (A²s) 380
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 1400
Rated breaking capacity I1 AC (kA) 100000
Weight (gr) 10
Price List €1.60/pc
Quantity

Fuse 10x38 aM 500V 12A

Reference 5006307.12.0 - Manufacturer SIBA
Class aM
Rated current In (A) 12
Rated Voltage Un AC (V) 500
Applicable standards IEC
Power loss (W) 0,65
Fuse Dimension (mm) 10x38
Melting I²t value (A²s) 580
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 2100
Rated breaking capacity I1 AC (kA) 100000
Weight (gr) 10
Price List €1.60/pc
Quantity

Fuse 22x58 gG 690V with striker 50A

Reference 5006108.50.0 - Manufacturer SIBA
Class gG
Rated current In (A) 50
Rated Voltage Un AC (V) 690
Applicable standards IEC
Power loss (W) 5,9
Fuse Dimension (mm) 22x58
Melting I²t value (A²s) 7100
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 11500
Rated breaking capacity I1 AC (kA) 100000
Weight (gr) 70
Price List €11.37/pc
Quantity

Fuse 10x38 aM 500V 2A

Reference 5006307.2.0 - Manufacturer SIBA
Class aM
Rated current In (A) 2
Rated Voltage Un AC (V) 500
Applicable standards IEC
Power loss (W) 0,15
Fuse Dimension (mm) 10x38
Melting I²t value (A²s) 40
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 90
Rated breaking capacity I1 AC (kA) 100000
Weight (gr) 10
Price List €1.54/pc
Quantity
Product added to compare.
Product added to wishlist