Home

Fuse NH2 500V gB 160A

Reference 2000403.160.0 - Manufacturer SIBA
Class gB
Rated current In (A) 160
Rated Voltage Un AC (V) 500
Dimension NH2
Power loss (W) 21
Melting I²t value (A²s) 9000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 36000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 610
Price List €127.44/pc
Quantity

Fuse NH2 500V gB 125A

Reference 2000403.125.0 - Manufacturer SIBA
Class gB
Rated current In (A) 125
Rated Voltage Un AC (V) 500
Dimension NH2
Power loss (W) 16
Melting I²t value (A²s) 5600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 22000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 610
Price List €124.61/pc
Quantity

Fuse NH2 500V Ty with top indicator 160A

Reference 2000412.160.0 - Manufacturer SIBA
Class Ty
Rated current In (A) 160
Rated Voltage Un AC (V) 500
Dimension NH2
Power loss (W) 16
Melting I²t value (A²s) 62000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 280000
Rated breaking capacity I1 AC (kA) 100000
Weight (gr) 610
Price List €68.74/pc
Quantity

Fuse NH1 TY-gG 500V 80A

Reference 2000316.80.0 - Manufacturer SIBA
Class aM
Rated current In (A) 80
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 7,4
Melting I²t value (A²s) 13900
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 318
Total clearing I²t @Un AC (A²s) 23800
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 290
Product available on request Ask for more information

Fuse NH2 500V Ty with top indicator 200A

Reference 2000412.200.0 - Manufacturer SIBA
Class Ty
Rated current In (A) 200
Rated Voltage Un AC (V) 500
Dimension NH2
Power loss (W) 19
Melting I²t value (A²s) 140000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 560000
Rated breaking capacity I1 AC (kA) 100000
Weight (gr) 610
Price List €68.75/pc
Quantity

Fuse NH2 500V Ty with top indicator 224A

Reference 2000412.224.0 - Manufacturer SIBA
Class Ty
Rated current In (A) 224
Rated Voltage Un AC (V) 500
Dimension NH2
Power loss (W) 21
Melting I²t value (A²s) 180000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 790000
Rated breaking capacity I1 AC (kA) 100000
Weight (gr) 610
Price List €75.37/pc
Quantity

Fuse NH1 TY-gG 500V 63A

Reference 2000316.63.0 - Manufacturer SIBA
Class aM
Rated current In (A) 63
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 6,5
Melting I²t value (A²s) 9200
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 318
Total clearing I²t @Un AC (A²s) 15700
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 290
Product available on request Ask for more information

Fuse NH1 TY-gG 500V 250A

Reference 2000316.250.0 - Manufacturer SIBA
Class aM
Rated current In (A) 250
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 21
Melting I²t value (A²s) 177000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 318
Total clearing I²t @Un AC (A²s) 302000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 290
Product available on request Ask for more information

Fuse NH1 TY-gG 500V 50A

Reference 2000316.50.0 - Manufacturer SIBA
Class aM
Rated current In (A) 50
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 4,8
Melting I²t value (A²s) 6600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 318
Total clearing I²t @Un AC (A²s) 11300
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 290
Product available on request Ask for more information

Fuse NH1 TY-gG 500V 35A

Reference 2000316.35.0 - Manufacturer SIBA
Class aM
Rated current In (A) 35
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 3,9
Melting I²t value (A²s) 3400
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 318
Total clearing I²t @Un AC (A²s) 5900
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 290
Product available on request Ask for more information

Fuse NH0 gG 500V double indicator 20A

Reference 2000213.20.0 - Manufacturer SIBA
Class aM
Rated current In (A) 20
Rated Voltage Un AC (V) 500
Dimension NH0
Applicable standards IEC
Power loss (W) 2,7
Melting I²t value (A²s) 760
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 1480
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 240
Price List €14.88/pc
Quantity

Fuse NH0 gG 500V double indicator 160A

Reference 2000213.160.0 - Manufacturer SIBA
Class aM
Rated current In (A) 160
Rated Voltage Un AC (V) 500
Dimension NH0
Applicable standards IEC
Power loss (W) 12,8
Melting I²t value (A²s) 78500
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 226600
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 267
Price List €9.49/pc
Quantity
Product added to compare.
Product added to wishlist