Home

Fuse NH1 gG 500V double indicator 35A

Reference 2000313.35.0 - Manufacturer SIBA
Class aM
Rated current In (A) 35
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 3,9
Melting I²t value (A²s) 3100
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 7610
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 260
Price List €15.70/pc
Quantity

Fuse NH1 gG 500V double indicator 40A

Reference 2000313.40.0 - Manufacturer SIBA
Class aM
Rated current In (A) 40
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 4,3
Melting I²t value (A²s) 4700
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 11300
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 250
Price List €15.70/pc
Quantity

Fuse NH1 gG 500V double indicator 50A

Reference 2000313.50.0 - Manufacturer SIBA
Class aM
Rated current In (A) 50
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 5,1
Melting I²t value (A²s) 5900
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 13600
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 300
Price List €9.05/pc
Quantity

Fuse NH1 gG 500V double indicator 63A

Reference 2000313.63.0 - Manufacturer SIBA
Class aM
Rated current In (A) 63
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 5,8
Melting I²t value (A²s) 10300
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 26400
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 260
Price List €9.06/pc
Quantity

Fuse NH1 gG 500V double indicator 80A

Reference 2000313.80.0 - Manufacturer SIBA
Class aM
Rated current In (A) 80
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 6,5
Melting I²t value (A²s) 17300
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 45500
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 260
Price List €9.06/pc
Quantity

Fuse NH2 500V Ty with top indicator 355A

Reference 2000412.355.0 - Manufacturer SIBA
Class Ty
Rated current In (A) 355
Rated Voltage Un AC (V) 500
Dimension NH2
Power loss (W) 32
Melting I²t value (A²s) 490000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 2200000
Rated breaking capacity I1 AC (kA) 100000
Weight (gr) 610
Price List €100.42/pc
Quantity

Fuse NH2 500V Ty with top indicator 250A

Reference 2000412.250.0 - Manufacturer SIBA
Class Ty
Rated current In (A) 250
Rated Voltage Un AC (V) 500
Dimension NH2
Power loss (W) 24
Melting I²t value (A²s) 220000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 960000
Rated breaking capacity I1 AC (kA) 100000
Weight (gr) 610
Price List €75.37/pc
Quantity

Fuse NH1 TY-gG 500V 100A

Reference 2000316.100.0 - Manufacturer SIBA
Class aM
Rated current In (A) 100
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 8,6
Melting I²t value (A²s) 26000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 318
Total clearing I²t @Un AC (A²s) 44600
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 290
Product available on request Ask for more information

Fuse NH1 TY-gG 500V 125A

Reference 2000316.125.0 - Manufacturer SIBA
Class aM
Rated current In (A) 125
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 11
Melting I²t value (A²s) 36200
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 318
Total clearing I²t @Un AC (A²s) 62000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 290
Product available on request Ask for more information

Fuse NH1 TY-gG 500V 160A

Reference 2000316.160.0 - Manufacturer SIBA
Class aM
Rated current In (A) 160
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 14
Melting I²t value (A²s) 63900
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 318
Total clearing I²t @Un AC (A²s) 110000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 290
Product available on request Ask for more information

Fuse NH1 TY-gG 500V 80A

Reference 2000316.80.0 - Manufacturer SIBA
Class aM
Rated current In (A) 80
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 7,4
Melting I²t value (A²s) 13900
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 318
Total clearing I²t @Un AC (A²s) 23800
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 290
Product available on request Ask for more information

Fuse NH2 500V Ty with top indicator 160A

Reference 2000412.160.0 - Manufacturer SIBA
Class Ty
Rated current In (A) 160
Rated Voltage Un AC (V) 500
Dimension NH2
Power loss (W) 16
Melting I²t value (A²s) 62000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 280000
Rated breaking capacity I1 AC (kA) 100000
Weight (gr) 610
Price List €68.74/pc
Quantity