Home

Fuse NH2 TY-gG 500V 160A

Reference 2000416.160.0 - Manufacturer SIBA
Class aM
Rated current In (A) 160
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC
Power loss (W) 14
Melting I²t value (A²s) 63900
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 318
Total clearing I²t @Un AC (A²s) 110000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 330
Product available on request Ask for more information

Fuse NH2 TY-gG 500V 125A

Reference 2000416.125.0 - Manufacturer SIBA
Class aM
Rated current In (A) 125
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC
Power loss (W) 11
Melting I²t value (A²s) 36200
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 318
Total clearing I²t @Un AC (A²s) 62000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 330
Price List €197.44/pc
Quantity

Fuse NH2 TY-gG 500V 100A

Reference 2000416.100.0 - Manufacturer SIBA
Class aM
Rated current In (A) 100
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC
Power loss (W) 8,6
Melting I²t value (A²s) 26000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 318
Total clearing I²t @Un AC (A²s) 44600
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 330
Price List €197.43/pc
Quantity

Fuse NH2 gTr 400V top indicator 361A

Reference 2000415.361.0 - Manufacturer SIBA
Class gTr
Rated current In (A) 361
Rated Voltage Un AC (V) 400
Dimension NH2
Power loss (W) 27
Melting I²t value (A²s) 415400
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 400
Total clearing I²t @Un AC (A²s) 970000
Rated breaking capacity I1 AC (kA) 100000
Weight (gr) 630
Price List €117.72/pc
Quantity

Fuse NH2 gTr 400V top indicator 108A

Reference 2000415.108.0 - Manufacturer SIBA
Class gTr
Rated current In (A) 108
Rated Voltage Un AC (V) 400
Dimension NH2
Power loss (W) 11
Melting I²t value (A²s) 18900
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 400
Total clearing I²t @Un AC (A²s) 44000
Rated breaking capacity I1 AC (kA) 100000
Weight (gr) 650
Price List €99.38/pc
Quantity

Fuse NH2 gTr 400V top indicator 180A

Reference 2000415.180.0 - Manufacturer SIBA
Class gTr
Rated current In (A) 180
Rated Voltage Un AC (V) 400
Dimension NH2
Power loss (W) 15
Melting I²t value (A²s) 76000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 400
Total clearing I²t @Un AC (A²s) 173000
Rated breaking capacity I1 AC (kA) 100000
Weight (gr) 650
Price List €99.40/pc
Quantity

Fuse NH2 gTr 400V top indicator 231A

Reference 2000415.231.0 - Manufacturer SIBA
Class gTr
Rated current In (A) 231
Rated Voltage Un AC (V) 400
Dimension NH2
Power loss (W) 18
Melting I²t value (A²s) 139600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 400
Total clearing I²t @Un AC (A²s) 326000
Rated breaking capacity I1 AC (kA) 100000
Weight (gr) 650
Price List €100.66/pc
Quantity

Fuse NH2 gTr 400V top indicator 72A

Reference 2000415.72.0 - Manufacturer SIBA
Class gTr
Rated current In (A) 72
Rated Voltage Un AC (V) 400
Dimension NH2
Power loss (W) 8.5
Melting I²t value (A²s) 6950
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 400
Total clearing I²t @Un AC (A²s) 15800
Rated breaking capacity I1 AC (kA) 100000
Weight (gr) 610
Price List €99.38/pc
Quantity

Fuse NH2 gTr 400V top indicator 289A

Reference 2000415.289.0 - Manufacturer SIBA
Class gTr
Rated current In (A) 289
Rated Voltage Un AC (V) 400
Dimension NH2
Power loss (W) 22
Melting I²t value (A²s) 226600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 400
Total clearing I²t @Un AC (A²s) 514000
Rated breaking capacity I1 AC (kA) 100000
Weight (gr) 610
Price List €109.60/pc
Quantity

Fuse NH1 gG 500V double indicator 16A

Reference 2000313.16.0 - Manufacturer SIBA
Class aM
Rated current In (A) 16
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 4,2
Melting I²t value (A²s) 420
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 810
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 260
Price List €15.81/pc
Quantity

Fuse NH1 gG 500V double indicator 160A

Reference 2000313.160.0 - Manufacturer SIBA
Class aM
Rated current In (A) 160
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 12,8
Melting I²t value (A²s) 78500
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 226600
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 287
Price List €9.61/pc
Quantity

Fuse NH1 gG 500V double indicator 20A

Reference 2000313.20.0 - Manufacturer SIBA
Class aM
Rated current In (A) 20
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 2,7
Melting I²t value (A²s) 760
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 1480
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 260
Price List €15.80/pc
Quantity
Product added to compare.
Product added to wishlist