Home

Fuse NH2 gG 500V double indicator 315A

Reference 2000413.315.0 - Manufacturer SIBA
Class aM
Rated current In (A) 315
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC
Power loss (W) 23
Melting I²t value (A²s) 513000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 1164000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 620
Price List €19.34/pc
Quantity

Fuse NH2 gG 500V double indicator 35A

Reference 2000413.35.0 - Manufacturer SIBA
Class aM
Rated current In (A) 35
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC
Power loss (W) 3,9
Melting I²t value (A²s) 3100
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 7610
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 290
Price List €16.47/pc
Quantity

Fuse NH2 gG 500V double indicator 355A

Reference 2000413.355.0 - Manufacturer SIBA
Class aM
Rated current In (A) 355
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC
Power loss (W) 30
Melting I²t value (A²s) 616000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 1483000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 606
Price List €18.38/pc
Quantity

Fuse NH2 gG 500V double indicator 400A

Reference 2000413.400.0 - Manufacturer SIBA
Class aM
Rated current In (A) 400
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC
Power loss (W) 32
Melting I²t value (A²s) 859000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 2008000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 620
Price List €18.52/pc
Quantity

Fuse NH2 gG 500V double indicator 50A

Reference 2000413.50.0 - Manufacturer SIBA
Class aM
Rated current In (A) 50
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC
Power loss (W) 5,1
Melting I²t value (A²s) 5900
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 13600
Total clearing I²t @Un AC (A²s) 5900
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 290
Price List €10.21/pc
Quantity

Fuse NH2 gG 500V double indicator 63A

Reference 2000413.63.0 - Manufacturer SIBA
Class aM
Rated current In (A) 63
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC
Power loss (W) 5,8
Melting I²t value (A²s) 10300
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 26400
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 290
Price List €10.22/pc
Quantity

Fuse NH2 gG 500V double indicator 80A

Reference 2000413.80.0 - Manufacturer SIBA
Class aM
Rated current In (A) 80
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC
Power loss (W) 6,5
Melting I²t value (A²s) 17300
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 88600
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 302
Price List €13.05/pc
Quantity

Fuse NH2 TY-gG 500V 200A

Reference 2000416.200.0 - Manufacturer SIBA
Class aM
Rated current In (A) 200
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC
Power loss (W) 19
Melting I²t value (A²s) 116000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 318
Total clearing I²t @Un AC (A²s) 193000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 330
Price List €306.38/pc
Quantity

Fuse NH2 TY-gG 500V 100A

Reference 2000416.100.0 - Manufacturer SIBA
Class aM
Rated current In (A) 100
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC
Power loss (W) 8,6
Melting I²t value (A²s) 26000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 318
Total clearing I²t @Un AC (A²s) 44600
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 330
Price List €197.43/pc
Quantity

Fuse NH2 TY-gG 500V 125A

Reference 2000416.125.0 - Manufacturer SIBA
Class aM
Rated current In (A) 125
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC
Power loss (W) 11
Melting I²t value (A²s) 36200
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 318
Total clearing I²t @Un AC (A²s) 62000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 330
Price List €197.44/pc
Quantity

Fuse NH2 TY-gG 500V 160A

Reference 2000416.160.0 - Manufacturer SIBA
Class aM
Rated current In (A) 160
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC
Power loss (W) 14
Melting I²t value (A²s) 63900
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 318
Total clearing I²t @Un AC (A²s) 110000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 330
Product available on request Ask for more information

Fuse NH2 TY-gG 500V 315A

Reference 2000416.315.0 - Manufacturer SIBA
Class aM
Rated current In (A) 315
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC
Power loss (W) 25
Melting I²t value (A²s) 331000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 318
Total clearing I²t @Un AC (A²s) 620000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 620
Price List €352.94/pc
Quantity