Home

Fuse 36kV TV 22x360 0,1A

Reference 3044511.0,1.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 0,1
Rated Voltage Un AC (V) 36000
Applicable standards IEC
Power loss (W) 7
Melting I²t value (A²s) 0,14
Voltage of total clearing I2t test 36000
Total clearing I²t @Un AC (A²s) 0,15
Rated breaking capacity I1 AC (kA) 40000
Price List $273.84/pc
Quantity

Fuse 36kV TV 22x360 1A

Reference 3044511.1.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 1
Rated Voltage Un AC (V) 36000
Applicable standards IEC
Power loss (W) 6.3
Melting I²t value (A²s) 1,8
Voltage of total clearing I2t test 36000
Total clearing I²t @Un AC (A²s) 13
Rated breaking capacity I1 AC (kA) 40000
Product available on request Ask for more information

Fuse 36kV TV 22x360 2A

Reference 3044511.2.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 2
Rated Voltage Un AC (V) 36000
Applicable standards IEC
Power loss (W) 24
Melting I²t value (A²s) 2,9
Voltage of total clearing I2t test 36000
Total clearing I²t @Un AC (A²s) 21
Rated breaking capacity I1 AC (kA) 40000
Price List $342.30/pc
Quantity

Fuse BR Motors 7,2kV 403mm 230A

Reference 3045955.12R.0 - Manufacturer SIBA
Class HH Motors
Rated current In (A) 230
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Power loss (W) 105
Fuse Dimension (mm) 76x403
Melting I²t value (A²s) 170000
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 6300
Total clearing I²t @Un AC (A²s) 930000
Rated breaking capacity I1 AC (kA) 50000
Product available on request Ask for more information

Fuse BR Motors 7,2kV 403mm 70A

Reference 3045955.2R.0 - Manufacturer SIBA
Class HH Motors
Rated current In (A) 70
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Power loss (W) 55
Fuse Dimension (mm) 76x403
Melting I²t value (A²s) 6300
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 6300
Total clearing I²t @Un AC (A²s) 37500
Rated breaking capacity I1 AC (kA) 50000
Product available on request Ask for more information

Fuse BR Motors 7,2kV 403mm 100A

Reference 3045955.3R.0 - Manufacturer SIBA
Class HH Motors
Rated current In (A) 100
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Power loss (W) 81
Fuse Dimension (mm) 76x403
Melting I²t value (A²s) 9000
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 6300
Total clearing I²t @Un AC (A²s) 47000
Rated breaking capacity I1 AC (kA) 50000
Product available on request Ask for more information

Fuse BR Motors 7,2kV 403mm 130A

Reference 3045955.4R.0 - Manufacturer SIBA
Class HH Motors
Rated current In (A) 130
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Power loss (W) 93
Fuse Dimension (mm) 76x403
Melting I²t value (A²s) 20400
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 6300
Total clearing I²t @Un AC (A²s) 122000
Rated breaking capacity I1 AC (kA) 50000
Product available on request Ask for more information

Fuse BR Motors 7,2kV 403mm 150A

Reference 3045955.5R.0 - Manufacturer SIBA
Class HH Motors
Rated current In (A) 150
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Power loss (W) 96
Fuse Dimension (mm) 76x403
Melting I²t value (A²s) 37600
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 6300
Total clearing I²t @Un AC (A²s) 215000
Rated breaking capacity I1 AC (kA) 50000
Product available on request Ask for more information

Fuse BR Motors 7,2kV 403mm 170A

Reference 3045955.6R.0 - Manufacturer SIBA
Class HH Motors
Rated current In (A) 170
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Power loss (W) 105
Fuse Dimension (mm) 76x403
Melting I²t value (A²s) 49000
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 6300
Total clearing I²t @Un AC (A²s) 269000
Rated breaking capacity I1 AC (kA) 50000
Product available on request Ask for more information

Fuse BR Motors 7,2kV 403mm 200A

Reference 3045955.9R.0 - Manufacturer SIBA
Class HH Motors
Rated current In (A) 200
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Power loss (W) 102
Fuse Dimension (mm) 76x403
Melting I²t value (A²s) 100400
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 6300
Total clearing I²t @Un AC (A²s) 562000
Rated breaking capacity I1 AC (kA) 50000
Product available on request Ask for more information

Fuse BR Motors 7,2kV 403mm 390A

Reference 3046055.18R.0 - Manufacturer SIBA
Class HH Motors
Rated current In (A) 390
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Power loss (W) 190
Fuse Dimension (mm) 76x403
Melting I²t value (A²s) 485000
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 6300
Total clearing I²t @Un AC (A²s) 2450000
Rated breaking capacity I1 AC (kA) 50000
Weight (gr) 8720
Product available on request Ask for more information

Fuse BR Motors 7,2kV 403mm 650A

Reference 3046155.36R.0 - Manufacturer SIBA
Class HH Motors
Rated current In (A) 650
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Power loss (W) 284
Fuse Dimension (mm) 76x403
Melting I²t value (A²s) 1527000
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 6300
Total clearing I²t @Un AC (A²s) 7635000
Rated breaking capacity I1 AC (kA) 50000
Weight (gr) 8720
Product available on request Ask for more information

Fuse 24kV 67x442 back-up oil applications +striker 50A 80N

Reference 3046513.50.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 50
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 108
Rated breaking capacity I1 DC (kA) 63000
Fuse Dimension (mm) 67x442
Melting I²t value (A²s) 5700
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 33000
Weight (gr) 3720
Product available on request Ask for more information

Fuse 36kV 53x442 back-up oil applications +striker 6,3A 80N

Reference 3046613.6,3.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 6,3
Rated Voltage Un AC (V) 36000
Applicable standards IEC
Power loss (W) 44
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 45
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 36000
Total clearing I²t @Un AC (A²s) 360
Rated breaking capacity I1 AC (kA) 40000
Product available on request Ask for more information

Fuse 40,5kV 254x63,5 back-up BV 0,5A

Reference 3050311.0,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 0,5
Rated Voltage Un AC (V) 40500
Applicable standards IEC
Power loss (W) 7
Fuse Dimension (mm) 254x63,5
Melting I²t value (A²s) 0,225
Fuse Connection/Terminal type Cylindrical
Weight (gr) 1940
Product available on request Ask for more information
Product added to compare.
Product added to wishlist