Home

NRAB - Fuse 690V AC aR NH00 with indicator 25A

Reference 458.370.74.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 25
Rated Voltage Un AC (V) 690
Dimension NH00
Applicable standards IEC
Power loss (W) 4,6
Series name NRAB
Melting I²t value (A²s) 55
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 770
Total clearing I²t @Un AC (A²s) 265
Rated breaking capacity I1 AC (kA) 200000
Product available on request Ask for more information

B100 - Fuse 1000VDC aBat 1000A - 132,7mm - Tin Plated

Reference 459.971.59.0.0 - Manufacturer FAULTRAP
Class aBat
Rated current In (A) 1000
Applicable standards IEC, UL
Power loss (W) 175
Rated Voltage Un DC (V) 1000
Time costant L/R (ms) 2
Series name B100
Rated breaking capacity I1 DC (kA) 100000
Fuse Dimension (mm) 63,5x167
Melting I²t value (A²s) 373500
Minimum breaking current (A) 10000
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 1000
Total clearing I²t @Un AC (A²s) 1095000
Product available on request Ask for more information

B025 - Fuse 1000VDC aBat 300A - 100,3mm - Silver Plated

Reference 460.577.02.0.0 - Manufacturer FAULTRAP
Class aBat, aR
Rated current In (A) 300
Applicable standards IEC, UL
Power loss (W) 47
Rated Voltage Un DC (V) 1000
Time costant L/R (ms) 2
Series name B025
Rated breaking capacity I1 DC (kA) 100
Fuse Dimension (mm) 38x129
Melting I²t value (A²s) 23300
Minimum breaking current (A) 2400
Fuse Connection/Terminal type Screw fixing
Fixing connection centres (mm) 100
Total clearing I²t @Un AC (A²s) 51000
Product available on request Ask for more information

10TD - Fuse 10x38 500VAC aM/aR 6A

Reference 476.305.98.0.0 - Manufacturer FAULTRAP
Class aM, aR
Rated current In (A) 6
Rated Voltage Un AC (V) 500
Applicable standards IEC, UL
Series name 10TD
Fuse Dimension (mm) 10x38
Melting I²t value (A²s) 125
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 295
Rated breaking capacity I1 AC (kA) 50000
Product available on request Ask for more information

ZRDU - Fuse holder 10x85 1500VDC IEC/UL 3P

Reference 474.281.28.0.0 - Manufacturer FAULTRAP
Rated current In (A) 32
Rated Voltage Un AC (V) 1000
Applicable standards IEC, UL
Rated Voltage Un DC (V) 1500
Series name ZRDU
Fuse Dimension (mm) 10x85
Fuse Connection/Terminal type Cylindrical
Rated Power Acceptance 8.5
Number of poles 3
Weight (gr) 308
Price List €12.19/pc
Quantity

NR2A-Fuse 000/80 aR 700VDC/690VAC with ind. w/o lug 25A

Reference 474.918.90.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 25
Rated Voltage Un AC (V) 690
Dimension 000
Applicable standards IEC
Power loss (W) 4,6
Rated Voltage Un DC (V) 700
Time costant L/R (ms) 2
Series name NR2A
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 55
Fuse Connection/Terminal type Screw fixing
Fixing connection centres (mm) 80
Voltage of total clearing I2t test 700
Total clearing I²t @Un AC (A²s) 200
Rated breaking capacity I1 AC (kA) 200000
Product available on request Ask for more information

20PV27 - Fuse 2000VDC gPV 27x85mm inline copper 4AWG 125A

Reference 476.045.27.0.0 - Manufacturer FAULTRAP
Class gPV
Rated current In (A) 125
Applicable standards IEC
Power loss (W) 23.4
Rated Voltage Un DC (V) 2000
Time costant L/R (ms) 1-3
Series name 20PV27
Rated breaking capacity I1 DC (kA) 50
Fuse Dimension (mm) 27x85
Melting I²t value (A²s) 11220
Fuse Connection/Terminal type In-line for copper cable
Product available on request Ask for more information

G103 - Fuse 500V 10x38 gG 25A

Reference 480.450.20.0.0 - Manufacturer FAULTRAP
Class gG
Rated current In (A) 25
Rated Voltage Un AC (V) 500
Applicable standards IEC
Power loss (W) 2,4
Fuse Dimension (mm) 10x38
Melting I²t value (A²s) 56,5
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 360
Rated breaking capacity I1 AC (kA) 100000
Product available on request Ask for more information

NR2A-Fuse 000/80 aR 700VDC/690VAC with ind. w/o lug 200A

Reference 480.504.71.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 200
Rated Voltage Un AC (V) 690
Dimension 000
Applicable standards IEC
Power loss (W) 48.5
Rated Voltage Un DC (V) 700
Time costant L/R (ms) 2
Series name NR2A
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 5370
Fuse Connection/Terminal type Screw fixing
Fixing connection centres (mm) 80
Voltage of total clearing I2t test 700
Total clearing I²t @Un AC (A²s) 19600
Rated breaking capacity I1 AC (kA) 200000
Price List €17.66/pc
Quantity

G103 - Fuse 500V 10x38 gG 3A

Reference 472.927.63.0.0 - Manufacturer FAULTRAP
Class gG
Rated current In (A) 3
Rated Voltage Un AC (V) 500
Applicable standards IEC
Power loss (W) 0,7
Fuse Dimension (mm) 10x38
Melting I²t value (A²s) 3
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 19
Rated breaking capacity I1 AC (kA) 100000
Product available on request Ask for more information
Product added to compare.
Product added to wishlist