Home

Fuse 150V DC 35x59mm aBat BS 150A

Reference 5005438.150.0 - Manufacturer SIBA
Rated current In (A) 150
Applicable standards IEC, UL
Power loss (W) 28
Rated Voltage Un DC (V) 150
Rated breaking capacity I1 DC (kA) 40000
Fuse Dimension (mm) 35x59
Melting I²t value (A²s) 1000
Fuse Connection/Terminal type BS
Voltage of total clearing I2t test 150
Total clearing I²t @Un AC (A²s) 3800
Price List €400.26/pc
Quantity

Fuse 150V DC 35x59mm aBat BS 160A

Reference 5005438.160.0 - Manufacturer SIBA
Rated current In (A) 160
Applicable standards IEC, UL
Power loss (W) 29
Rated Voltage Un DC (V) 150
Rated breaking capacity I1 DC (kA) 40000
Fuse Dimension (mm) 35x59
Melting I²t value (A²s) 1300
Fuse Connection/Terminal type BS
Voltage of total clearing I2t test 150
Total clearing I²t @Un AC (A²s) 4900
Product available on request Ask for more information

Fuse aR 17,5x60,5 240V 180A

Reference 5005506.180.0 - Manufacturer SIBA
Class aR
Rated current In (A) 180
Rated Voltage Un AC (V) 240
Applicable standards IEC
Power loss (W) 24
Fuse Dimension (mm) 17,5x60,5
Melting I²t value (A²s) 2300
Fuse Connection/Terminal type BS
Voltage of total clearing I2t test 240
Total clearing I²t @Un AC (A²s) 15700
Rated breaking capacity I1 AC (kA) 100000
Weight (gr) 20
Product available on request Ask for more information

Fuse aR 17,5x60,5 240V 12A

Reference 5005506.12.0 - Manufacturer SIBA
Class aR
Rated current In (A) 12
Rated Voltage Un AC (V) 240
Applicable standards IEC
Power loss (W) 2
Fuse Dimension (mm) 17,5x60,5
Melting I²t value (A²s) 8
Fuse Connection/Terminal type BS
Voltage of total clearing I2t test 240
Total clearing I²t @Un AC (A²s) 41
Rated breaking capacity I1 AC (kA) 100000
Weight (gr) 20
Product available on request Ask for more information

Fuse aR 17,5x60,5 240V 125A

Reference 5005506.125.0 - Manufacturer SIBA
Class aR
Rated current In (A) 125
Rated Voltage Un AC (V) 240
Applicable standards IEC
Power loss (W) 16
Fuse Dimension (mm) 17,5x60,5
Melting I²t value (A²s) 1000
Fuse Connection/Terminal type BS
Voltage of total clearing I2t test 240
Total clearing I²t @Un AC (A²s) 6800
Rated breaking capacity I1 AC (kA) 100000
Weight (gr) 20
Product available on request Ask for more information

Fuse aR 17,5x60,5 240V 16A

Reference 5005506.16.0 - Manufacturer SIBA
Class aR
Rated current In (A) 16
Rated Voltage Un AC (V) 240
Applicable standards IEC
Power loss (W) 2,4
Fuse Dimension (mm) 17,5x60,5
Melting I²t value (A²s) 18
Fuse Connection/Terminal type BS
Voltage of total clearing I2t test 240
Total clearing I²t @Un AC (A²s) 92
Rated breaking capacity I1 AC (kA) 100000
Weight (gr) 20
Product available on request Ask for more information

Fuse aR 17,5x60,5 240V 160A

Reference 5005506.160.0 - Manufacturer SIBA
Class aR
Rated current In (A) 160
Rated Voltage Un AC (V) 240
Applicable standards IEC
Power loss (W) 22
Fuse Dimension (mm) 17,5x60,5
Melting I²t value (A²s) 1500
Fuse Connection/Terminal type BS
Voltage of total clearing I2t test 240
Total clearing I²t @Un AC (A²s) 10200
Rated breaking capacity I1 AC (kA) 100000
Weight (gr) 20
Price List €269.19/pc
Quantity

Fuse aR 17,5x60,5 240V 32A

Reference 5005506.32.0 - Manufacturer SIBA
Class aR
Rated current In (A) 32
Rated Voltage Un AC (V) 240
Applicable standards IEC
Power loss (W) 4,5
Fuse Dimension (mm) 17,5x60,5
Melting I²t value (A²s) 40
Fuse Connection/Terminal type BS
Voltage of total clearing I2t test 240
Total clearing I²t @Un AC (A²s) 270
Rated breaking capacity I1 AC (kA) 100000
Weight (gr) 20
Product available on request Ask for more information

Fuse aR 17,5x60,5 240V 40A

Reference 5005506.40.0 - Manufacturer SIBA
Class aR
Rated current In (A) 40
Rated Voltage Un AC (V) 240
Applicable standards IEC
Power loss (W) 5.3
Fuse Dimension (mm) 17,5x60,5
Melting I²t value (A²s) 100
Fuse Connection/Terminal type BS
Voltage of total clearing I2t test 240
Total clearing I²t @Un AC (A²s) 700
Rated breaking capacity I1 AC (kA) 100000
Weight (gr) 20
Product available on request Ask for more information

Fuse aR 17,5x60,5 240V 35A

Reference 5005506.35.0 - Manufacturer SIBA
Class aR
Rated current In (A) 35
Rated Voltage Un AC (V) 240
Applicable standards IEC
Power loss (W) 5
Fuse Dimension (mm) 17,5x60,5
Melting I²t value (A²s) 63
Fuse Connection/Terminal type BS
Voltage of total clearing I2t test 240
Total clearing I²t @Un AC (A²s) 430
Rated breaking capacity I1 AC (kA) 100000
Weight (gr) 20
Product available on request Ask for more information

Fuse aR 17,5x60,5 240V 100A

Reference 5005506.100.0 - Manufacturer SIBA
Class aR
Rated current In (A) 100
Rated Voltage Un AC (V) 240
Applicable standards IEC
Power loss (W) 13
Fuse Dimension (mm) 17,5x60,5
Melting I²t value (A²s) 620
Fuse Connection/Terminal type BS
Voltage of total clearing I2t test 240
Total clearing I²t @Un AC (A²s) 4300
Rated breaking capacity I1 AC (kA) 100000
Weight (gr) 20
Product available on request Ask for more information

Fuse aR 17,5x60,5 240V 20A

Reference 5005506.20.0 - Manufacturer SIBA
Class aR
Rated current In (A) 20
Rated Voltage Un AC (V) 240
Applicable standards IEC
Power loss (W) 3,3
Fuse Dimension (mm) 17,5x60,5
Melting I²t value (A²s) 25
Fuse Connection/Terminal type BS
Voltage of total clearing I2t test 240
Total clearing I²t @Un AC (A²s) 130
Rated breaking capacity I1 AC (kA) 100000
Weight (gr) 20
Product available on request Ask for more information
Product added to compare.
Product added to wishlist