Home

C100 - Fuse 690V aR size 1 M8 500A

Reference 980.470.39.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 500
Rated Voltage Un AC (V) 690
Dimension SQB2
Applicable standards IEC
Power loss (W) 76
Fixing dimensions M8
Melting I²t value (A²s) 26000
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 186000
Rated breaking capacity I1 AC (kA) 100000
Product available on request Ask for more information

B500 - Fuse 1500VDC aBat 4xM10 with micro adapter 1500A

Reference 980.290.26.0.0 - Manufacturer FAULTRAP
Class aBat
Rated current In (A) 1500
Applicable standards IEC
Power loss (W) 350
Rated Voltage Un DC (V) 1500
Time costant L/R (ms) 3
Series name B500
Rated breaking capacity I1 DC (kA) 250000
Fuse Dimension (mm) 103x144
Fixing dimensions M10
Melting I²t value (A²s) 1156000
Minimum breaking current (A) 17000
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 6270000
Product available on request Ask for more information

C300 - Fuse 660VAC aR M12 1100A

Reference 980.066.34.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 1100
Rated Voltage Un AC (V) 690
Dimension SQB3
Applicable standards IEC
Power loss (W) 136
Series name C300
Fuse Dimension (mm) 76x50
Fixing dimensions M12
Melting I²t value (A²s) 200800
Fuse Connection/Terminal type Screw fixing
Total clearing I²t @Un AC (A²s) 1150000
Rated breaking capacity I1 AC (kA) 200
Product available on request Ask for more information

B300 - Fuse 1000V DC aBat DC 2xM12 1400A

Reference 979.833.74.0.0 - Manufacturer FAULTRAP
Class aBat
Rated current In (A) 1400
Applicable standards IEC
Power loss (W) 262
Rated Voltage Un DC (V) 1000
Time costant L/R (ms) 2
Series name B300
Rated breaking capacity I1 DC (kA) 100
Fuse Dimension (mm) 86x106
Fixing dimensions M12
Melting I²t value (A²s) 731600
Minimum breaking current (A) 14000
Fuse Connection/Terminal type Screw fixing
Total clearing I²t @Un DC (A²s) 2195000
Price List €450.85/pc
Quantity

20PV14 - Fuse 2000VDC gPV 14x85 inline 25A

Reference 979.300.79 .0.0 - Manufacturer FAULTRAP
Class gPV
Rated current In (A) 25
Applicable standards IEC
Power loss (W) 7.6
Rated Voltage Un DC (V) 2000
Time costant L/R (ms) 1-3
Series name 20PV14
Rated breaking capacity I1 DC (kA) 50
Fuse Dimension (mm) 14x85
Melting I²t value (A²s) 118
Fuse Connection/Terminal type In-line for copper cable
Product available on request Ask for more information

X800 - Fuse 22x65mm 800VAC gG 2A

Reference 977.978.94.0.0 - Manufacturer FAULTRAP
Class gG
Rated current In (A) 2
Rated Voltage Un AC (V) 800
Applicable standards IEC
Power loss (W) 1,1
Series name X800
Fuse Dimension (mm) 22x65
Melting I²t value (A²s) 2,5
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 800
Total clearing I²t @Un AC (A²s) 45
Rated breaking capacity I1 AC (kA) 80000
Price List €16.34/pc
Quantity

NR2B - Fuse 00/80 aR 700VDC/690VAC with ind. w/o lug 200A

Reference 969.788.60.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 200
Rated Voltage Un AC (V) 690
Dimension 000
Applicable standards IEC, UL
Power loss (W) 48.5
Rated Voltage Un DC (V) 700
Time costant L/R (ms) 2
Series name NR2B
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 5370
Fuse Connection/Terminal type Screw fixing
Fixing connection centres (mm) 80
Voltage of total clearing I2t test 700
Total clearing I²t @Un AC (A²s) 19600
Rated breaking capacity I1 AC (kA) 200000
Product available on request Ask for more information

AB22 - Fuse 22x65 1000VDC aBat 60A

Reference 972.091.49.0.0 - Manufacturer FAULTRAP
Class aBat
Rated current In (A) 60
Applicable standards IEC
Power loss (W) 11
Rated Voltage Un DC (V) 1000
Time costant L/R (ms) 1-3
Series name AB22
Rated breaking capacity I1 DC (kA) 10
Fuse Dimension (mm) 22x65
Melting I²t value (A²s) 1270
Minimum breaking current (A) 480
Fuse Connection/Terminal type Cylindrical
Total clearing I²t @Un DC (A²s) 7000
Product available on request Ask for more information

E103 - Fuse 10x38 700VDC aBAT 40A

Reference 971.827.03.0.0 - Manufacturer FAULTRAP
Class aBat
Rated current In (A) 40
Applicable standards IEC
Power loss (W) 4,6
Rated Voltage Un DC (V) 700
Series name E103
Rated breaking capacity I1 DC (kA) 20000
Fuse Dimension (mm) 10x38
Fuse Connection/Terminal type Cylindrical
Price List €4.60/pc
Quantity

M100 - Fuse 1000V DC 10x38 25A

Reference 970.958.15.0.0 - Manufacturer FAULTRAP
Class EV full
Rated current In (A) 25
Applicable standards UL
Power loss (W) 5
Rated Voltage Un DC (V) 1000
Series name M100
Fuse Dimension (mm) 10x38
Fixing dimensions M10
Fuse Connection/Terminal type Cylindrical
Product available on request Ask for more information

NR2A - Fuse DIN000 80mm aR 700VDC/690VAC no ind 125A

Reference 969.839.51.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 125
Rated Voltage Un AC (V) 690
Dimension 000
Applicable standards IEC
Power loss (W) 27.5
Rated Voltage Un DC (V) 700
Time costant L/R (ms) 2
Series name NR2A
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 2100
Fuse Connection/Terminal type Screw fixing
Fixing connection centres (mm) 80
Voltage of total clearing I2t test 700
Total clearing I²t @Un AC (A²s) 7700
Rated breaking capacity I1 AC (kA) 200000
Price List €13.02/pc
Quantity

UR22 - Fuse 690V AC 22x58 fixing on pcb 16A

Reference 968.375.45.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 16
Rated Voltage Un AC (V) 690
Applicable standards IEC
Power loss (W) 5,1
Series name UR22
Melting I²t value (A²s) 12,5
Fuse Connection/Terminal type PCB Mount Terminals
Total clearing I²t @Un AC (A²s) 56
Rated breaking capacity I1 AC (kA) 200
Product available on request Ask for more information
Product added to compare.
Product added to wishlist