Fuse VT 24kV 24x359 1A

Reference 3038011.1.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 1
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 10
Fuse Dimension (mm) 24x359
Melting I²t value (A²s) 0,6
Fuse Connection/Terminal type BS
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 1,9
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 367
Price List €108.56/pc
Quantity

Fuse VT 24kV 24x359 1E

Reference 3038011.1E.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 1
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 10
E-Rating 1
Fuse Dimension (mm) 24x359
Melting I²t value (A²s) 1
Fuse Connection/Terminal type BS
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 10
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 366
Product available on request Ask for more information

Fuse VT 24kV 24x359 2A

Reference 3038011.2.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 2
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 16
Fuse Dimension (mm) 24x359
Melting I²t value (A²s) 3,2
Fuse Connection/Terminal type BS
Voltage of total clearing I2t test 36000
Total clearing I²t @Un AC (A²s) 9,9
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 393
Price List €108.66/pc
Quantity

Fuse VT 24kV 24x359 2E

Reference 3038011.2E.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 2
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 14
Fuse Dimension (mm) 24x359
Melting I²t value (A²s) 4
Fuse Connection/Terminal type BS
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 38
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 393
Price List €86.85/pc
Quantity

Fuse VT 24kV 24x359 3A

Reference 3038011.3.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 3
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 18
Fuse Dimension (mm) 24x359
Melting I²t value (A²s) 16,1
Fuse Connection/Terminal type BS
Voltage of total clearing I2t test 36000
Total clearing I²t @Un AC (A²s) 47,8
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 387
Price List €108.91/pc
Quantity

Fuse VT 24kV 24x359 3E

Reference 3038011.3E.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 3
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 23
E-Rating 3
Fuse Dimension (mm) 24x359
Melting I²t value (A²s) 16
Fuse Connection/Terminal type BS
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 155
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 386
Product available on request Ask for more information

Fuse VT 24kV 24x359 4E

Reference 3038011.4E.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 4
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 31
E-Rating 4
Fuse Dimension (mm) 24x359
Melting I²t value (A²s) 25
Fuse Connection/Terminal type BS
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 240
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 400
Product available on request Ask for more information

Fuse VT 36kV 24x359 0,5A

Reference 3038111.0,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 0,5
Rated Voltage Un AC (V) 36000
Applicable standards IEC
Power loss (W) 8,6
Fuse Dimension (mm) 24x359
Melting I²t value (A²s) 0,1
Fuse Connection/Terminal type BS
Voltage of total clearing I2t test 36000
Total clearing I²t @Un AC (A²s) 0,9
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 800
Price List €105.38/pc
Quantity

Fuse VT 36kV 24x359 ANSI- IEEE 0,5E

Reference 3038111.0,5E.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 0,5
Rated Voltage Un AC (V) 36000
Applicable standards IEC
Power loss (W) 8,6
Fuse Dimension (mm) 24x359
Melting I²t value (A²s) 0,1
Fuse Connection/Terminal type BS
Voltage of total clearing I2t test 36000
Total clearing I²t @Un AC (A²s) 0,9
Rated breaking capacity I1 AC (kA) 25000
Weight (gr) 800
Price List €105.33/pc
Quantity

Fuse VT 36kV 24x359 ANSI- IEEE 0,75E

Reference 3038111.0,75E.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 0,75
Rated Voltage Un AC (V) 36000
Applicable standards IEC
Power loss (W) 10,5
E-Rating 0,75
Fuse Dimension (mm) 24x359
Melting I²t value (A²s) 0,4
Fuse Connection/Terminal type BS
Voltage of total clearing I2t test 36000
Total clearing I²t @Un AC (A²s) 3,5
Rated breaking capacity I1 AC (kA) 25000
Weight (gr) 800
Product available on request Ask for more information

Fuse VT 36kV 24x359 1A

Reference 3038111.1.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 1
Rated Voltage Un AC (V) 36000
Applicable standards IEC
Power loss (W) 13
Fuse Dimension (mm) 24x359
Melting I²t value (A²s) 1
Fuse Connection/Terminal type BS
Voltage of total clearing I2t test 36000
Total clearing I²t @Un AC (A²s) 10
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 386
Price List €131.80/pc
Quantity

Fuse VT 36kV 24x359 ANSI- IEEE 1E

Reference 3038111.1E.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 1
Rated Voltage Un AC (V) 36000
Applicable standards IEC
Power loss (W) 13
E-Rating 1
Fuse Dimension (mm) 24x359
Melting I²t value (A²s) 1
Fuse Connection/Terminal type BS
Voltage of total clearing I2t test 36000
Total clearing I²t @Un AC (A²s) 10
Rated breaking capacity I1 AC (kA) 25000
Weight (gr) 800