All Products

NR2B - Fuse DIN00 80mm aR 700VDC/690VAC with ind. lug 32A

Reference 886.723.70.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 32
Rated Voltage Un AC (V) 690
Dimension 000
Applicable standards IEC, UL
Power loss (W) 7
Rated Voltage Un DC (V) 700
Time costant L/R (ms) 2
Series name NR2B
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 80
Fuse Connection/Terminal type Screw fixing
Fixing connection centres (mm) 80
Voltage of total clearing I2t test 700
Total clearing I²t @Un AC (A²s) 300
Rated breaking capacity I1 AC (kA) 200000
Product available on request Ask for more information

BP22 -Fuse 22x65mm cylindrical 40A

Reference 889.666.78.0.0 - Manufacturer FAULTRAP
Class gBat, gR
Rated current In (A) 40
Applicable standards IEC, UL
Power loss (W) 6,5
Rated Voltage Un DC (V) 1000
Series name BP22
Rated breaking capacity I1 DC (kA) 100000
Fuse Dimension (mm) 22x65
Fuse Connection/Terminal type Cylindrical
Total clearing I²t @Un AC (A²s) 415
Product available on request Ask for more information

X100 - Fuse 22x65mm 1000VAC gG 25A

Reference 892.468.08.0.0 - Manufacturer FAULTRAP
Class gG
Rated current In (A) 25
Rated Voltage Un AC (V) 1000
Applicable standards IEC
Power loss (W) 4.7
Series name X100
Fuse Dimension (mm) 22x65
Melting I²t value (A²s) 53
Fuse Connection/Terminal type Cylindrical
Total clearing I²t @Un AC (A²s) 465
Rated breaking capacity I1 AC (kA) 50
Product available on request Ask for more information

RL12 - Fuse 25x60mm 125VDC 300A

Reference 892.578.11.0.0 - Manufacturer FAULTRAP
Rated current In (A) 300
Power loss (W) 25
Rated Voltage Un DC (V) 125
Time costant L/R (ms) 3
Series name RL12
Rated breaking capacity I1 DC (kA) 10000
Melting I²t value (A²s) 11000
Total clearing I²t @Un AC (A²s) 105000
Price List €6.17/pc
Quantity

NRAB - Fuse 690V AC aR NH00 with indicator 180A

Reference 893.247.32.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 180
Rated Voltage Un AC (V) 690
Dimension NH00
Applicable standards IEC
Power loss (W) 42,5
Series name NRAB
Melting I²t value (A²s) 4120
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 770
Total clearing I²t @Un AC (A²s) 20100
Rated breaking capacity I1 AC (kA) 200000
Product available on request Ask for more information

EV65.1000 - Fuse 1000VDC 22x65 cylindrical 40A

Reference 893.574.49.0.0 - Manufacturer FAULTRAP
Class EV full
Rated current In (A) 40
Applicable standards UL
Power loss (W) 9
Rated Voltage Un DC (V) 1000
Time costant L/R (ms) 2,5
Series name EV65.1000
Rated breaking capacity I1 DC (kA) 25000
Fuse Dimension (mm) 22x65
Melting I²t value (A²s) 425
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 1000
Total clearing I²t @Un AC (A²s) 1750
Product available on request Ask for more information

20PV22 - Fuse 2000VDC gPV 22x85mm inline aluminum 4AWG 45A

Reference 894.116.24.0.0 - Manufacturer FAULTRAP
Class gPV
Rated current In (A) 45
Applicable standards IEC
Power loss (W) 11.9
Rated Voltage Un DC (V) 2000
Time costant L/R (ms) 1-3
Series name 20PV22
Rated breaking capacity I1 DC (kA) 50
Fuse Dimension (mm) 22x85
Melting I²t value (A²s) 6600
Fuse Connection/Terminal type In-line for aluminum cable
Product available on request Ask for more information

V108 - Fuse 10x85 1500VDC gPV In-line 15A

Reference 895.746.71.0.0 - Manufacturer FAULTRAP
Class gPV
Rated current In (A) 15
Applicable standards IEC, UL
Power loss (W) 3,71
Rated Voltage Un DC (V) 1500
Series name V108
Rated breaking capacity I1 DC (kA) 20000
Fuse Dimension (mm) 10x85
Melting I²t value (A²s) 37,32
Fuse Connection/Terminal type Cylindrical In-line
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 314
Product available on request Ask for more information

G103 - Fuse 500V 10x38 gG 8A

Reference 898.934.30.0.0 - Manufacturer FAULTRAP
Class gG
Rated current In (A) 8
Rated Voltage Un AC (V) 500
Applicable standards IEC
Power loss (W) 1,2
Fuse Dimension (mm) 10x38
Melting I²t value (A²s) 6,3
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 50
Rated breaking capacity I1 AC (kA) 100000
Product available on request Ask for more information

BPF3 - Fuse 1500VDC aBat M12 1000A

Reference 900.131.26.0.0 - Manufacturer FAULTRAP
Class aBat
Rated current In (A) 1000
Applicable standards IEC
Power loss (W) 230
Rated Voltage Un DC (V) 1500
Time costant L/R (ms) 3
Series name BPF3
Rated breaking capacity I1 DC (kA) 100000
Fuse Dimension (mm) 76x140
Fixing dimensions M12
Melting I²t value (A²s) 590000
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 3365000
Product available on request Ask for more information
Filter by
Manufacturer
Series name
Class
Rated Voltage Un AC (V)
Rated Voltage Un DC (V)
Rated insultaion voltage AC (V)
Rated insulated voltage DC (V)
Applicable standards
Product added to compare.
Product added to wishlist